Monitoring of Patients Treated With Particle Therapy Using Positron-Emission-Tomography (PET): The MIRANDA Study
NCT01528670 · Status: WITHDRAWN · Type: OBSERVATIONAL
Last updated 2018-05-17
Summary
The purpose of this clinical study is to investigate the clinical feasibility and effectiveness of off-line Positron-Emission-Tomography (PET) quality assurance for promoting the accuracy of proton and carbon ion beam therapy. One main clinical advantage of ion therapy over conventional radiation therapy is the excellent conformation of the delivered dose to the tumour volume while well sparing the surrounding healthy tissue. However, clinical exploitation of this potential to the maximum extent requires in-vivo validation of the actual treatment delivery and, in particular, of the ion beam range within the patient. Since the primary ions are completely stopped in the target volume as opposed to photon radiation, no conventional quality assurance techniques like transmission electronic portal imaging can be applied to monitor ion beam therapy. Hence, ion treatment planning currently relies on models and experimental data accurately validated in tissue-equivalent targets, but no direct verification of the actual treatment delivery and of the ion beam range within the patient is possible in standard clinical practice.
At present, PET offers the unique possibility to monitor the precision of ion irradiation in-vivo and non-invasively. The method is based on the detection of the b+-activity which is formed as a by-product of the irradiation, i.e. without administration of radio-tracers to the patient. A positive clinical impact of in-beam (i.e. during the irradiation) PET monitoring has been demonstrated for carbon ion therapy in the pilot project at GSI Darmstadt, Germany, and promising clinical data of post-radiation PET/CT imaging have been recently reported for passive proton beam delivery in USA and Japan. Therefore, a pilot clinical study is hereby proposed at the Heidelberg Ion Therapy Center in order to 1) assess the applicability of post-radiation PET imaging to scanned ion beam delivery, 2) identify the patient population which may benefit from it and 3) extract population-based information on the reliability of the beam range in different tumour locations for all the ion species clinically available at HIT.
The investigated patients are expected to benefit from this study, since in case of detected deviations between planned and actual treatment delivery a proper correction could be applied in the next irradiation fraction, assuring an overall better treatment than without any monitoring. Moreover, site-specific patient-population information on the ion range precision at HIT might enable improvement of the CT-range calibration curve as well as safe reduction of the treatment margins to promote enhanced treatment plan conformality for full clinical exploitation of the promises of ion beam therapy.
Conditions
- Particle Therapy
Sponsors & Collaborators
-
University Hospital Heidelberg
lead OTHER
Principal Investigators
-
Stephanie E Combs, MD · University Hospital of Heidelberg
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-05-31
- Primary Completion
- 2022-05-31
- Completion
- 2022-05-31
Countries
- Germany
Study Locations
More Related Trials
-
Applying PET/MR in Neuroendocrine Tumors - Imaging Dynamic Processes in Both Modalities
NCT04152928 ·Status: UNKNOWN ·Phase: NA
-
PET/MRI Perfusion and CT Perfusion in Solid Tumors
NCT02314962 ·Status: TERMINATED
-
Efficacy of PET/MRI in Detecting Metastatic Disease in Endometrial Cancer
NCT02765698 ·Status: TERMINATED
-
Evaluation of PET/MRI in Children With Cancer
NCT01839747 ·Status: COMPLETED ·Phase: NA
-
Response Monitoring Trial in Patients With Suspected Recurrence of Glioblastoma
NCT02176720 ·Status: TERMINATED ·Phase: PHASE1
-
Evaluating the Usefulness of 18F-AlF-FAPI PET/ CT in Orbital Neoplasms
NCT06791226 ·Status: RECRUITING ·Phase: NA
-
Positron Emission Tomography/Magnetic Resonance Imaging in Patients
NCT01557881 ·Status: TERMINATED ·Phase: NA
-
68Ga-ICAM-1pep PET/CT in Cancer Patients
NCT04596670 ·Status: RECRUITING ·Phase: EARLY_PHASE1
-
18F-mFBG LAFOV PET/CT Compared to 123I-mIBG Scintigraphy SPECT/CT for Evaluation of Children With Neuroblastoma
NCT05826158 ·Status: RECRUITING ·Phase: NA
-
Positron Emission Tomography Imaging Using Copper Cu 64 TP3805 in Patients With Breast Cancer
NCT02810873 ·Status: TERMINATED ·Phase: NA
-
CD8 PET Imaging in Metastatic Solid Tumours
NCT06534190 ·Status: RECRUITING ·Phase: PHASE2
-
Use of Integrated PET/CT as a First Line Staging and Re-staging Technique in Oncologic Patient.
NCT06168877 ·Status: COMPLETED
-
PET and/or MRI Scans in Assessing Tumor Response in Patients Receiving Antiangiogenesis Therapy
NCT00019565 ·Status: COMPLETED ·Phase: PHASE1
-
In-Room PET in Proton Radiation Therapy
NCT01228448 ·Status: COMPLETED ·Phase: NA
-
FAP PET/CT or PET/MR Production in the Diagnosis, Staging, and Efficacy Assessment of Malignant Tumors Application
NCT06270394 ·Status: COMPLETED ·Phase: NA
-
Development of Radiation Free Whole Body Magnetic Resonance (MR) Imaging Technique for Staging Children With Cancer
NCT01542879 ·Status: RECRUITING ·Phase: PHASE1/PHASE2
-
18F-FAPI-04 PET/CT and PET/MR in Patients With Various Types of Malignant Tumors
NCT06557590 ·Status: RECRUITING
-
A Phase I/II Study of [124I]mIBG PET/CT in Neuroblastoma
NCT02043899 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
FDG PET Imaging in Diagnosing Patients With Glioblastoma
NCT02885272 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
An International Study on the Use of PET/CT in Radiotherapy Planning in Low and Middle Income Countries
NCT02247713 ·Status: UNKNOWN
-
Diagnostic Comparison of PET-magnetic Resonance and PET-CT in Patients With Oncologic Diseases
NCT02316431 ·Status: COMPLETED
-
68Ga-TCR-FAPI PET/CT in Patients With Various Types of Cancer
NCT06084767 ·Status: RECRUITING ·Phase: NA
-
64-Cu Labeled Brain PET/MRI for MM-302 in Advanced HER2+ Cancers With Brain Mets
NCT02735798 ·Status: WITHDRAWN ·Phase: EARLY_PHASE1
-
Early Therapy Response Monitoring in Melanoma Patients Using PET/MRI
NCT03132090 ·Status: UNKNOWN ·Phase: NA
-
Explore the Clinical Value of 68Ga-DOTANOC PET/CT and 18F-FDG PET/CT in Neuroendocrine Neoplasms
NCT03288597 ·Status: UNKNOWN