Study for the Artificial Pancreas Project : Determination of a Tuning Strategy of Metabolic Profiles
NCT01282567 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 3
Last updated 2012-02-03
Summary
The Artificial Pancreas Project developed by SUPELEC and the University Hospital of Rennes is focused on the evaluation of an original control algorithm that computes appropriate subcutaneous insulin infusion in response to continuous glucose measurements The results during a 24-hour closed-loop period will be compared with those of the open-loop. The implementation of this algorithm named Error Dynamics Shaping (EDS) requires as a preliminary a phase of identification of the parameters of the model (insulin pharmacokinetics and effect on glucose metabolism) followed by a phase of optimization i.e. a personalized adjustment of the damping parameters of EDS.
The present study aims to formalize this procedure of identification/optimization of the parameters of the model and controller EDS. They will be determined in type -1 diabetic patients using insulin therapy and under conditions free from disturbances such as those generated by the glucidic meals, i.e. during a period of glucidic fast. Three variables will determine this procedure: blood glucose, insulin concentration and insulin doses.
Conditions
Interventions
- OTHER
-
Blood samples
The study will be proposed to four patients hospitalized in the Diabetes Unit for a glucidic fast test carried out during 24 hours (lunch, dinner and breakfast). Blood samples will be taken every 20 minutes during 6 hours and 40 minutes to measure plasma insulin concentration and blood glucose. T0 will correspond to the first modification of the insulin basal flow (in more or less) or to the first insulin bolus corrector, usually administered if capillary blood glucose reaches 1.8 g/l. The capillary blood glucose monitoring will be performed every two hours by the nurse.
Sponsors & Collaborators
-
Rennes University Hospital
lead OTHER
Principal Investigators
-
jean-yves poirier · Rennes University Hospital
-
isabelle guilhem · Rennes University Hospital
Study Design
- Allocation
- NA
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-05-31
- Primary Completion
- 2011-09-30
- Completion
- 2011-09-30
Countries
- France
Study Locations
More Related Trials
-
Closed-loop Insulin Delivery Systems in Pancreatic Diabetes
NCT06227650 ·Status: COMPLETED
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 60 Hours in Adults With Type 1 Diabetes
NCT01966393 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
Portable Artificial Pancreas Applied for Youth and Adolescents
NCT05543850 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 15 Weeks in Adolescents and Adults With Type 1 Diabetes
NCT02846857 ·Status: WITHDRAWN ·Phase: PHASE2
-
Study the Feasibility of Permanent Use of inControl for the Treatment of Type 1 Diabetes
NCT02892604 ·Status: TERMINATED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults With Type 2 Diabetes Under Intensive Insulin Therapy
NCT02490085 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults and Adolescents With Type 1 Diabetes
NCT01754337 ·Status: COMPLETED ·Phase: PHASE2
-
Assessment of a New Closed-loop Algorithm in Type 1 Diabetes (Saddle Point Model Predictive Control : SP-MPC) (PPA)
NCT02061488 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study Using Zone-MPC Controller (Zone-Model Predictive Control) and Health Monitoring System (HMS)
NCT01472406 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Insulin in Total Parenteral Nutrition
NCT02706119 ·Status: COMPLETED ·Phase: PHASE4
-
Hybrid Artificial Pancreas in Home Setting
NCT02153190 ·Status: COMPLETED ·Phase: PHASE2
-
Artificial Pancreas Control System in an Inpatient Setting
NCT01552603 ·Status: COMPLETED ·Phase: PHASE2
-
Android Artificial Pancreas System (Android APS) Versus Control-IQ
NCT05165615 ·Status: UNKNOWN ·Phase: NA
-
Artificial Pancreas With Different Stress Assessments in the Outpatient Setting
NCT04142229 ·Status: COMPLETED ·Phase: NA
-
The Set-Point Study: Evaluating Effects of Changing Glucose Target on Bionic Pancreas Performance
NCT02509065 ·Status: COMPLETED ·Phase: NA
-
Is the Artificial Pancreas, Without Carbohydrate Counting, Efficient and Safe in an Outpatient Setting
NCT04793165 ·Status: COMPLETED ·Phase: NA
-
An Outpatient Study of Automated Blood Glucose Control With an Insulin-Only Bionic Pancreas
NCT02536950 ·Status: COMPLETED ·Phase: NA
-
Obtain a Good Blood Glucose Control With the Paradigm Real Time System
NCT00441129 ·Status: COMPLETED ·Phase: NA
-
Algorithm to Control Postprandial, Post Exercise and Night Glucose Excursions in a Portable Closed Loop Format,
NCT03858062 ·Status: COMPLETED ·Phase: NA
-
Feasibility and Safety Study of the Automated Insulin Delivery Closed Loop System Pancreas4ALL
NCT04835350 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Insulin Production From Native Pancreas in Patients With Pancreas Transplants
NCT00246844 ·Status: COMPLETED
-
Feasibility Study of a Portable Artificial Pancreas System in Type 1 Diabetes Mellitus (T1DM) - Montpellier
NCT01447979 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Study to Assess the Metabolic Impact of IRTA© and Patients Satisfaction in Type 1 Diabetic Patients, Treated by Either Insulin Pump or Multiple Daily Insulin Injections, and Using Freestyle Libre®, a Real-time Continuous Glucose Monitoring
NCT04211220 ·Status: COMPLETED ·Phase: NA
-
Closed-Loop Glucagon Administration For Hypoglycemia Treatment
NCT02181127 ·Status: COMPLETED ·Phase: NA