Validation of a Novel Oscillometric-Based Algorithm for Determination of the Ankle-Brachial Index
NCT01165437 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 161
Last updated 2011-02-24
Summary
Peripheral arterial disease (PAD) is a highly prevalent medical condition. Patients with PAD are usually diagnosed on the basis of the ankle-brachial index. The ankle-brachial index is the ratio of ankle pressure to arm pressure after measurement of blood pressures in the arms and legs using a Doppler device. The need for dedicated equipment and trained personnel, along with the time required to perform the test, have been identified as barriers to widespread implementation of ankle-brachial index screening. The use of automated oscillometric devices for blood pressure measurement has been applied to leg pressure measurement and determination of the ankle-brachial index with variable success. It will be beneficial to investigate a reliable oscillometric-based procedure that can accurately measure leg pressures for the ankle-brachial index across the entire spectrum of PAD severity.
In a previous pilot study completed in 2009 (IRB 08-823), the investigators gathered data from N=60 subjects which allowed for mathematical analysis of oscillometric waveforms derived from the lower extremities as compared to Doppler-based measurements of blood pressure. We used signal processing analysis and regression techniques to develop a two-step algorithm which will allow for accurate interpretation of oscillometric waveforms in normal/mild vs. moderate/severely diseased limb and accurate calculation of ankle pressure across the spectrum of peripheral artery disease severity.
This proposed project will validate this novel oscillometric ABI algorithm in a population of patients who have been identified as at risk for PAD and for whom screening ABI has been recommended by multiple professional organizations (AHA/ACC and American Diabetes Association). Arm, ankle, and toe pressure measurements will be made in the supine position using Doppler, oscillometric methods, and a photoplethysmographic sensor. The ankle-brachial index and toe-brachial index will be calculated.
Conditions
- Peripheral Arterial Disease
Interventions
- DEVICE
-
Blood Pressure Measurement
Systolic blood pressures will be obtained from each limb using Doppler, oscillometric, and photoplethysmographic (PPG) modalities.
Sponsors & Collaborators
-
The Cleveland Clinic
collaborator OTHER -
Summit Doppler Systems, Inc.
lead INDUSTRY
Eligibility
- Min Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2010-10-31
- Primary Completion
- 2011-01-31
- Completion
- 2011-01-31
Countries
- United States
Study Locations
More Related Trials
-
Color Doppler and Peripheral Venous Catheters
NCT03889678 ·Status: COMPLETED
-
Central Venous Pressure Versus Inferior Vena Cava Distensibility Index in Assessing Fluid Responsiveness in Septic Shocked Patients
NCT07279064 ·Status: NOT_YET_RECRUITING
-
Augmented Velocity Index of Intra-abdominal, Carotid and Retinal Arteries
NCT05273905 ·Status: UNKNOWN
-
A Comparative Study of Portable Patch-type Carotid Ultrasound CADFlow and Desktop Ultrasound Machines
NCT07197411 ·Status: NOT_YET_RECRUITING
-
Subclavian Versus Inferior Vena Cava Collapsibility Indices.
NCT03337386 ·Status: COMPLETED ·Phase: NA
-
Variations in the Hemostatic System Induced by a Standardized Walking Test
NCT06418633 ·Status: RECRUITING ·Phase: NA
-
Venous Pressure Monitoring As a Predictor Of High-Flow Access In Prevalent Hemodialysis Patients
NCT07038993 ·Status: COMPLETED
-
New Technologies to Determine Carotid Plaque Vulnerability in Patients With Significant Carotid Plaques
NCT03335033 ·Status: COMPLETED ·Phase: PHASE2
-
A New Technique for Determining Limb Occlusion Pressure
NCT02620722 ·Status: COMPLETED ·Phase: NA
-
Ankle Measurements of Arterial Pressure: Semi-recumbent or Horizontal Position.
NCT06032169 ·Status: COMPLETED
-
Correlation of Arterial Blood Gas (ABG) and Venous Blood Gas (VBG) in the Undifferentiated Critically Ill Patient
NCT01287884 ·Status: COMPLETED ·Phase: NA
-
Microcirculation in Continuous Venovenous Hemofiltration Patients on the Intensive Care Unit
NCT01362088 ·Status: COMPLETED
-
Is Venous to Arterial Conversion (v-TAC) of Blood Gas Reliable in Critical Ill Patients in the ICU?
NCT03309423 ·Status: UNKNOWN
-
Correlation Between Peripheral Venous Pressure and Central Venous Pressure in the Cardiac Intensive Care Unit
NCT03526497 ·Status: TERMINATED
-
Bedside Ultrasound for Fluid Estimation
NCT05159063 ·Status: COMPLETED
-
Evaluation of Doppler Flow From the Femoral Artery as a Reflection of Cardiac Flow in a Vascular Fluid Test
NCT02878369 ·Status: UNKNOWN
-
Bedside Ultrasound Measurement of the Inferior Vena Cava Correlates to Central Venous Pressure
NCT00596921 ·Status: UNKNOWN
-
Micro and Macro Circulation in Sepsis
NCT05694455 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Guided Peripheral Intravenous Catheter Insertion in the Hospitalized Patient: Long vs. Short Axis Placement
NCT01870661 ·Status: WITHDRAWN ·Phase: NA
-
Comparison of POC-test-equipment With the Laboratory
NCT02042417 ·Status: UNKNOWN ·Phase: PHASE4
-
Inferior Vena Cava (IVC) Diameters Before & After Interscalene Block
NCT03989076 ·Status: WITHDRAWN
-
TRanslesIonal Assessment of Gradients During Endovascular Therapy
NCT03163199 ·Status: COMPLETED
-
Ultrasound Guided Positioning of Central Venous Catheters
NCT04630236 ·Status: COMPLETED ·Phase: NA
-
Abdominal Aorta Palpation With Point of Care Ultrasound Imaging Measurements
NCT06211946 ·Status: COMPLETED
-
Central Venous Pressure (CVP) Assessment by Ultrasound and Physical Examination
NCT01099241 ·Status: COMPLETED