BOOST - Benefit of Frequent Optimization After Cardiac Resynchronization Therapy Device Replacement
NCT00929474 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 17
Last updated 2019-02-04
Summary
Cardiac resynchronization therapy (CRT) has shown improvement in mortality and morbidity in patients with left ventricular systolic dysfunction and congestive heart failure. Additionally in CRT patients it has been demonstrated that optimizing paced/sensed atrioventricular (AV) and interventricular (V-V) timings leads to immediate hemodynamic benefits and further improves cardiac function. Recent studies have shown that optimal paced/sensed AV and V-V delays change over time, which raises the question of how often optimization should be repeated. Thus, frequent re-optimization of these delays might be beneficial for maintaining significant improvement of cardiac function. However, it remains to be evaluated whether timing optimization may be beneficial on patients who have received CRT for a number of years and are now having the CRT device replaced.
Conditions
Interventions
- DEVICE
-
QuickOpt - SJM CRT (Group 1)
The patient's device is programmed to sequential Bi-V pacing mode with paced/sensed AV and V-V delays optimized using QuickOpt. For Group 1 patients, optimization using QuickOpt is performed at enrollment, 3, 6, 9 and 12 month visits.
- DEVICE
-
Control - SJM CRT (Group 2)
The patient's device is programmed to either simultaneous or sequential Bi-V pacing mode as per physician's discretion. The paced/sensed AV and V-V delays could be programmed empirically or optimized using any non-intracardiac electrogram (IEGM) based method as per sites standard of care. However, the Group 2 patients can be optimized only once within the first 4 weeks post CRT replacement. Any paced/sensed AV and V-V delay optimizations performed after 4 weeks post CRT replacement in Group 2 patients will be considered a protocol deviation.
Sponsors & Collaborators
-
Abbott Medical Devices
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2009-06-30
- Primary Completion
- 2010-09-30
- Completion
- 2010-09-30
Countries
- United States
Study Locations
More Related Trials
-
Ensure Cardiac Resynchronization Therapy Study
NCT00291564 ·Status: COMPLETED
-
Triple-site Biventricular Stimulation in the Optimization of CRT
NCT02350842 ·Status: COMPLETED ·Phase: NA
-
ECG Belt vs. Echocardiographic Optimization of CRT
NCT03305692 ·Status: COMPLETED ·Phase: NA
-
Risk Stratification and Benefits With Cardiac Resynchronization Therapy (CRT)
NCT00996086 ·Status: COMPLETED
-
Response of Cardiac Resynchronization Therapy Optimization With Ventricle to Ventricle Timing in Heart Failure Patients
NCT00187200 ·Status: COMPLETED ·Phase: PHASE4
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Optimization of CRT Using an ECG Vest
NCT02699944 ·Status: COMPLETED ·Phase: NA
-
Response to Cardiac Resynchronization Therapy of Previously Right Ventricular Paced Heart Failure Patients
NCT01466621 ·Status: COMPLETED
-
QuickOpt Chronic Study
NCT01172067 ·Status: COMPLETED ·Phase: NA
-
Adaptive Cardiac Resynchronization Therapy Optimization at Rest and During Exercise (AdOPT CRT)
NCT01475175 ·Status: TERMINATED ·Phase: NA
-
RethinQ Study - Evaluating Pacing in Heart Failure Patients
NCT00132977 ·Status: COMPLETED ·Phase: PHASE3
-
BOAT: Beta Blocker Uptitration With OptiVol After Cardiac Resynchronization Therapy (CRT)
NCT00433043 ·Status: TERMINATED ·Phase: PHASE4
-
Optimizing CRT With ECGI
NCT03492788 ·Status: TERMINATED ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) and Left Ventricular Assist Devices (LVAD) Therapy
NCT02083419 ·Status: COMPLETED
-
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
NCT07069738 ·Status: RECRUITING ·Phase: NA
-
Continued Access Clinical Trial of the SonRtip Lead and Automatic AV-VV Optimization Algorithm in the PARADYM RF SonR CRT-D
NCT02374801 ·Status: UNKNOWN ·Phase: NA
-
Interventricular Delay of Lumax HF-T for Heart Failure
NCT00508391 ·Status: COMPLETED ·Phase: PHASE2
-
B-Left HF: Biventricular Versus Left Univentricular Pacing With Implantable Cardiac Defibrillator (ICD) Back-Up in Heart Failure Patients
NCT00187213 ·Status: COMPLETED ·Phase: NA
-
'Effect of CRT on Defibrillation Threshold Estimates' Study
NCT00626093 ·Status: COMPLETED ·Phase: PHASE4
-
Acute and Cronic Evaluation of AV/PV and VV Delay IEGM Based Optimisation Algorithm-QuickSept Study
NCT02571868 ·Status: COMPLETED
-
Post Approval Registry of Corox OTW, Endocardial, Left Ventricular Steroid Lead, Bipolar
NCT00810264 ·Status: COMPLETED
-
Cardiac Resynchronisation Therapy Versus Rate-responsive Pacing in Heart Failure With Preserved Ejection Fraction
NCT03338374 ·Status: COMPLETED ·Phase: NA
-
Study to Evaluate the Superior Efficacy of Cardiac Resynchronization (SyncAVTM) Using the SyncAVTM Algorithm
NCT03961399 ·Status: COMPLETED ·Phase: NA
-
Paced And Sensed Electrical Delay in CRT Therapy (PASED CRT)
NCT02803775 ·Status: COMPLETED ·Phase: NA
-
Strategic Management to Optimize Response To Cardiac Resynchronization Therapy
NCT03089281 ·Status: COMPLETED ·Phase: NA