Influence of Bone Strength Measured by DensiProbe on Bone Related Fixation Failure
NCT00822159 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 198
Last updated 2011-10-10
Summary
Hip fractures mostly occur in elderly people with low bone strength. Bone strength is determined by bone mineral density (BMD), bone turnover, microarchitectural and geometrical properties of the bone. Dual energy x-ray absorptiometry (DXA) is the standard technique to measure BMD. However, BMD just provides information regarding the quantity of mineral in bone, which is only one component of bone strength. To date there is no reliable method to assess bone strength in vivo. Therefore, a method to assess bone strength beyond BMD would provide additional information regarding the patients' risk of bone related fixation failure after fracture fixation.
DensiProbe is a new diagnostic device that was developed for intra-operative assessment of mechanical stability of the bone in the proximal femur. It consists of a drill bit like tool and an electronic system to measure the peak torque to break-away of trabecular bone in the femoral head of patients undergoing DHS surgical treatment. In a cadaver study comparing bone mineral density measured by quantitative computed tomography with bone strength measured by DensiProbe a high correlation between these two parameters could be shown. In a clinical pilot study a significant correlation between DensiProbe measurements and BMD measured by DXA at the femoral neck in patients with hip fractures could be shown. However, no perfect correlation was expected because DensiProbe measures bone strength, which is only partly caused by BMD.
Bone related fixation failure, such as secondary loss of reduction, is influenced by bone strength, bone mineral density, fracture type, fracture reduction and primary positioning of the implant. The predictive value of DensiProbe measurements for secondary loss of reduction needs to be investigated. If DensiProbe turned out to be an effective screening tool for patients with low bone strength that are on higher risk of the aforementioned complications these patients may in future benefit from alternative treatment methods (e.g. augmentation techniques) in order to reduce bone related fixation failure.
The primary aim of the present study is to investigate if bone strength measured by DensiProbeTM Hip (DensiProbe) is an independent factor to predict secondary loss of reduction (screw migration of 5 mm or more and / or telescoping of 10 mm or more) in patients with hip fractures after fracture fixation with DHS.
Conditions
- Femoral Fractures
- Hip Fractures
- Osteoporosis
- Bone Density
Interventions
- DEVICE
-
DensiProbe Hip
DensiProbe (CE marked) is a mechanical probe, which is used intra-operatively to assess mechanical stability of the trabecular bone in the proximal femur. It consists of a drill bit like tool and an electronic system for measuring the peak torque to break-away of trabecular bone in the femoral head. DensiProbe measurements are designed to be integrated in the DHS surgical procedure.
Sponsors & Collaborators
-
AO Clinical Investigation and Publishing Documentation
lead OTHER
Principal Investigators
-
Norbert Suhm, MD · Universitätsspital Basel
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2008-11-30
- Primary Completion
- 2011-09-30
- Completion
- 2011-09-30
Countries
- Austria
- Germany
- Netherlands
- Switzerland
Study Locations
More Related Trials
-
ProspEctive Cohort Study on Multidisciplinary Approach to Femur FRactures' manAgement in Over 65 Population
NCT04127045 ·Status: COMPLETED
-
Stabilization of Fresh Unilateral Unstable Pertrochanteric Hip Fracture
NCT02788994 ·Status: UNKNOWN ·Phase: NA
-
Patient-Specific Precision Injury Signatures in Multiply Injured Orthopaedic Patients
NCT03772730 ·Status: COMPLETED
-
Comparison of Functional Recovery After Distal Intra-articular Radius Fracture With a Dorsal Tilt Treated With an Anterior Plate Versus a Posterior Plate
NCT03259906 ·Status: TERMINATED ·Phase: NA
-
Hemiarthroplasty Compared to Total Hip Arthroplasty for Displaced Femoral Neck Fractures in the Elderly-elderly
NCT02246335 ·Status: UNKNOWN ·Phase: NA
-
Identifying Risk Factors for Falls in Patients With a High Risk of Fracture Using Connected Insoles (FeetMe Monitor® Device)
NCT05155761 ·Status: UNKNOWN ·Phase: NA
-
Direct Anterior vs. Anterolateral Approach for Hip Arthroplasty After Femoral Neck Fracture in the Senior Population
NCT02959320 ·Status: COMPLETED ·Phase: NA
-
Early Weight Bearing on Supracondylar Distal Femur Fractures in Elderly Patients
NCT02475941 ·Status: COMPLETED ·Phase: NA
-
Mini Stem DEXA (Dual Energy X-ray Absorptiometry)
NCT01066936 ·Status: COMPLETED
-
Effectiveness of Adipose Tissue Derived Mesenchymal Stem Cells as Osteogenic Component in Composite Grafts
NCT01532076 ·Status: TERMINATED ·Phase: PHASE2
-
Comparison of Treatment Outcomes in Hip Fractures Surgically Fixed With Either a Two or Four Hole Device.
NCT00323232 ·Status: COMPLETED ·Phase: PHASE4
-
Radiostereometric Analysis of Acetabular Wear and Periprosthetic Bone Mineral Density Changes in Hemiarthroplasties
NCT00607516 ·Status: UNKNOWN ·Phase: NA
-
Utility of Cortical Bone Tissue Properties in the Assessment of Fracture Risk
NCT03076034 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Static Helical Screw Locking of Pertrochanteric Femur Fractures Using the TFN-A
NCT04851509 ·Status: RECRUITING ·Phase: NA
-
Proximal Femur Image Database Validation
NCT06351943 ·Status: ACTIVE_NOT_RECRUITING
-
Identification of Microcirculation and Inflammation After Minimal-invasive Osteosynthesis of the Proximal Femur
NCT01264172 ·Status: COMPLETED ·Phase: NA
-
Internal Fixation or Joint Replacement Therapy for Aged Hip Fracture Patients
NCT03407131 ·Status: UNKNOWN ·Phase: NA
-
DePuy Trochanteric (ATN) Nailing Clinical Outcomes Trial
NCT00546429 ·Status: COMPLETED
-
Novel Use of an Enhanced Fluoroscopic Imaging Device to Reduce Radiation Exposure and Operative Time During Intramedullary Nailing of Hip Fractures
NCT02856828 ·Status: TERMINATED ·Phase: NA
-
Follow-Up of the Prevision® Hip Stem
NCT04833634 ·Status: COMPLETED
-
Safety of Immediate Weight-Bearing as Tolerated After Well-Reduced Geriatric Hip
NCT06199739 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Performance of Y-STRUT® Medical Device to Strengthen Pre-fractural Tumour-induced Lesions at the Level of the Proximal Femur
NCT03579212 ·Status: TERMINATED
-
Influence of Osteoporosis on Clinical Outcomes of Mini-invasive Surgical Treatment of Proximal Humerus Fractures
NCT02750839 ·Status: UNKNOWN
-
Randomized Trial of Osteoporosis Intervention Strategies in Hip Fracture Patients
NCT00175175 ·Status: COMPLETED ·Phase: NA
-
Prospective Validation Study of the CD8+TEMRA Cells As a Prognostic Biomarker of Healing Outcome After Fracture
NCT06658379 ·Status: RECRUITING