OptiLink HF Study: Optimization of Heart Failure Management Using Medtronic OptiVol Fluid Status Monitoring and CareLink Network
NCT00769457 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 1002
Last updated 2025-07-03
Summary
Patients suffering from heart failure and a markedly reduced pumping capacity and sometimes desynchronization of the lower chambers of the heart have a higher risk of suffering sudden cardiac death.
These patients can be treated with an Implantable Cardiac Defibrillator that terminates dangerously fast heartbeats and in case of asynchronous pumping of the heart can also re-synchronize the lower chambers of the heart (ICD- or CRT-D-system). Patients that moreover suffered from a worsening of their cardiac status (cardiac decompensation) and had to be hospitalized for this reason have a higher risc to have following decompensations. New technology, incorporated into modern Medtronic ICD- and CRT-D-Systems, that measures the amount of water in the lungs is able to warn before such a dangerous worsening occurs. If coupled with modern data transmitting technology (CareLink), automatic information in case of a worsening of the cardiac status can be sent to caregivers, who in turn can react timely in order to prevent a worsening an subsequent hospitalization.
The study examines to which extent this new technology prevents potentially adverse cardiac situations and / or hospitalizations and has an influence of the duration of patient´s lives.
Conditions
Interventions
- DEVICE
-
Access Arm
Active OptiVol-System with CareAlert via CareLink
Sponsors & Collaborators
- collaborator INDUSTRY
-
Medtronic Cardiac Rhythm and Heart Failure
lead INDUSTRY
Principal Investigators
-
Michael Boehm, Professor · Universitätsklinikum des Saarlandes, Homburg-Saar
-
Johannes Brachmann, Professor · Klinikum Coburg GmbH
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2008-09-30
- Primary Completion
- 2014-11-30
- Completion
- 2014-11-30
Countries
- Germany
More Related Trials
-
Clinical Usefulness and Efficacy of Intrathoracic Impedance Monitoring Using the OptiVol Patient Alert(TM)
NCT00488501 ·Status: COMPLETED
-
OptiVol® Care Pathway
NCT00847288 ·Status: COMPLETED ·Phase: PHASE4
-
Feasibility Study of an Integrated Diagnostic System to Manage Heart Failure
NCT01045343 ·Status: COMPLETED ·Phase: NA
-
Care-HF CArdiac Resynchronization in Heart Failure
NCT00170300 ·Status: COMPLETED ·Phase: NA
-
Continued Access Protocol for the Evaluation of the OPTIMIZER Smart System
NCT03102437 ·Status: TERMINATED ·Phase: NA
-
Medtronic Observational Study in the "Real World" of Implantable Electronic Cardiac Devices
NCT01189630 ·Status: UNKNOWN
-
FAST (Fluid Accumulation Status Trial)
NCT00289276 ·Status: COMPLETED ·Phase: NA
-
Sensitivity of the InSync Sentry OptiVol Feature for the Prediction of Heart Failure
NCT00400985 ·Status: COMPLETED ·Phase: NA
-
Restoring Sinus Rhythm With Cardiac Resynchronization in Patients With Atrial Fibrillation (ReSync AF)
NCT00268294 ·Status: COMPLETED ·Phase: NA
-
Reveal LINQ™ Heart Failure
NCT02758301 ·Status: COMPLETED
-
Investigation to Optimize Hemodynamic Management of Left Ventricular Assist Devices Using the CardioMEMS™
NCT03247829 ·Status: COMPLETED
-
CORE: Study to Evaluate the Conducted AF-Response-Algorithm in Patients Suffering From Heart Failure and Atrial Fibrillation
NCT00170313 ·Status: TERMINATED ·Phase: PHASE4
-
OptiVol for Precision Medical Management of Heart Failure
NCT04206501 ·Status: TERMINATED ·Phase: NA
-
InSync Implantable Cardioverter Defibrillator Registry: Cardiac Resynchronization Therapy
NCT00289302 ·Status: COMPLETED
-
Evaluation of the Safety and Efficacy of the 2-lead OPTIMIZER® Smart System
NCT03339310 ·Status: COMPLETED ·Phase: NA
-
Optimised Decrement Evoked Potential (DeEP) Mapping to Guide Ventricular Tachycardia (VT) Ablation in Patients With Structural Heart Disease VT
NCT06937983 ·Status: RECRUITING ·Phase: NA
-
Evaluate Safety and Efficacy of the OPTIMIZER® System in Subjects With Moderate-to-Severe Heart Failure: FIX-HF-5C
NCT01381172 ·Status: COMPLETED ·Phase: NA
-
PARTNERS HF: Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure
NCT00279955 ·Status: COMPLETED
-
Post Approval Study (PAS) of the OPTIMIZER Smart and CCM Therapy
NCT03970343 ·Status: ACTIVE_NOT_RECRUITING
-
Precision Event Monitoring for Patients With Heart Failure Using HeartLogic
NCT03579641 ·Status: COMPLETED
-
MOnitoring REsynchronization deviCes and cARdiac patiEnts
NCT00885677 ·Status: TERMINATED ·Phase: NA
-
Interventricular Delay of Lumax HF-T for Heart Failure
NCT00508391 ·Status: COMPLETED ·Phase: PHASE2
-
Identification of the Pericardiophrenic Vein During Cardiac Device Implant Procedures to Prevent Extracardiac Stimulation
NCT01008670 ·Status: COMPLETED
-
Optimal Pacing Rate for Cardiac Resynchronization Therapy
NCT06445439 ·Status: RECRUITING ·Phase: NA
-
Relationship Between LINQ™ Subcutaneous Impedance and Right-sided Hemodynamic Measurements
NCT03608826 ·Status: COMPLETED ·Phase: NA