Evaluation of Blood Volume and Perceived Pain During Fingerstick Monitoring of Blood Glucose

NCT00741390 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 250

Last updated 2010-03-10

Study results available
· View outcomes & findings →

Summary

The procurement of blood for SMBG, usually via a finger stick, is considered by many patients to be the most painful portion of diabetes therapy. This has led to the marketing of smaller gauge lancets, lancing devices with variable depth settings and blood glucose sensors that require less blood for measurement.

In this study, two main outcomes were evaluated: The first, which was assessed at Visit 1, was whether specific combinations of lancets and lancing devices would yield sufficient blood volume to allow valid assessment of diabetic subjects' glucose levels. The other outcome, assessed at Visit 2, was the level of pain perceived by subjects during lancing with specific combinations of lancets and lancing devices. During Visit 2, pain assessment was done using a Visual Analog Scale and such that for each lancet/lancing device, the lowest lancing device setting that yielded a valid BG reading for each subject during Visit 1 was used. A third outcome measure, overall comfort with lancing, was also assessed at Visit 2.

A total of 5 combinations of lancets and lancing devices were evaluated.

These were as follows:

* BD/33G = BD Lancet device/BD 33G lancets (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)
* OTM/33G =OneTouch® Mini Lancet device / BD 33G lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)
* OTM/28G =OneTouch® Mini Lancet device / OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)
* OTU/28G = OneTouch® UltraSoft® Lancet device/OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)
* ACC/28G= Accu-Chek® Softclix Lancet device/Accu-Chek® Softclix 28G Lancet (BGM measured with Accu-Chek® Advantage BGM and Accu-Chek® Comfort Curve test strip)

After enrollment and qualification, subjects were assigned to one of 4 intervention arms. The arm assignment determined which 3 of the 5 combinations of lancets and lancing devices the subjects would evaluate in Visit 1 (for volume adequacy) and of these 3, which 2 they would evaluate in Visit 2 (pain during lancing). The lancet/lancing device combinations assigned to each arm are shown in the Assigned Interventions Table below.

Conditions

  • Diabetes Mellitus, Type 1
  • Diabetes Mellitus, Type 2

Interventions

DEVICE

BD/33G

BD Lancet device/BD 33G lancets (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

DEVICE

OTM / 33G

OneTouch® Mini Lancet device / BD 33G lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

DEVICE

OTU/28G

OneTouch® UltraSoft® Lancet device/OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ BGM) and OneTouch® Ultra® test strips)

DEVICE

ACC/28G

Accu-Chek® Softclix Lancet device/Accu-Chek® Softclix 28G Lancet (BGM measured with Accu-Chek® Advantage BGM and Accu-Chek® Comfort Curve test strip)

DEVICE

OTM/28G

OneTouch® Mini Lancet device / OneTouch® UltraSoft® 28G Lancet (BGM measured with the OneTouch® UltraMini™ (BGM) and OneTouch® Ultra® test strips)

Sponsors & Collaborators

  • Becton, Dickinson and Company

    lead INDUSTRY

Principal Investigators

  • Michael E Casser, MD · TKL Research, Inc.

  • Ronald L Rizer, PhD · Thomas J. Stephens & Associates

Study Design

Allocation
RANDOMIZED
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
70 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2008-08-31
Primary Completion
2008-09-30
Completion
2008-09-30

Countries

  • United States