Comparison of Breathing Events Detected by the SleepStyle 200 Auto Continuous Positive Airway Pressure (CPAP) Device to Attended Polysomnography

NCT00697424 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20

Last updated 2008-12-09

No results posted yet for this study

Summary

Obstructive Sleep Apnoea (OSA) is a common sleep-breathing disorder affecting around 2-4% of the population and is characterised by loud snoring, periodic collapse of the upper airway particular to sleep, sleep fragmentation, and sometimes daytime sleepiness. Health consequences include impaired cognitive functioning, quality of life, mood, and increased cardiovascular disease risk. Epidemiological studies have demonstrated that increased morbidity and mortality in a dose response manner with increasing severity of sleep disordered breathing.

The standard treatment for OSA is nasal Continuous Positive Airway Pressure (CPAP), which consists of pressurized air applied to the nose via a mask. Generally a single, optimal pressure is prescribed for a patient based on a full night or partial night study during which the pressure is adjusted by a technician until all sleep disordered breathing (SDB) events are abolished. Despite therapy efficacy, compliance to CPAP therapy is sub-optimal.

Due to low compliance it has become common for healthcare providers to follow up subject therapy efficacy through reporting software inherent in many current CPAP devices. Healthcare providers can use this reported data to make appropriate treatment decisions. For this reason the data needs to be accurate. The SleepStyle™ 200 Auto Series CPAP humidifier is an auto adjusting CPAP which stores comprehensive compliance data. The aim of this study is to compare the reliability of the SleepStyle™ 200 Auto Series CPAP data to laboratory-based PSG in detecting sleep disordered breathing.

Hypothesis: The SleepStyle™ 200 Auto Series reporting features accurately detects indices of sleep disordered breathing.

Conditions

  • Sleep Apnea, Obstructive

Interventions

DEVICE

SleepStyle 200 Auto Series CPAP Humidifier

The device will record on internal software perceived sleep disordered breathing events. Events will also be scored manually on the polysomnography (PSG. Results will then be compared.

Sponsors & Collaborators

  • Fisher and Paykel Healthcare

    lead INDUSTRY

Principal Investigators

  • Jessica R Hayward, Msc · Fisher & Paykel Healthcare

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2008-05-31
Primary Completion
2008-11-30
Completion
2008-11-30

Countries

  • New Zealand

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT00697424 on ClinicalTrials.gov