Intraoperative Warming Comparison of Devices
NCT00650260 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 42
Last updated 2012-10-29
Summary
Hypothermia is a common and serious complication during anesthesia and surgery. Anesthetic-induced hypothermia results from the inhibition of thermoregulatory control and exposure to cold operating room environment.
Various warming methods, such as warm blankets, forced-air warmers and circulating water mattresses, are currently used to prevent and treat mild perioperative hypothermia. All are cutaneous approaches that rely on heating the peripheral tissues in order to increase the thermal core temperature. Application of cutaneous warming system blankets/pads are limited by location/extent of operative site; for example, in certain procedures such as laparatomies, reconstructive plastic surgery or orthopedic surgery, only a limited amount of skin surface is available for warming application. The Dynatherm vitalHEAT technology takes advantage of the body's natural thermoregulatory system to channel thermal energy to the body's core non-invasively at a rapid rate. The vital heat (vH2) system is designed to treat hypothermia during the peri-operative period through a combination of localized heat and vacuum application to one hand \& forearm; this application 1) opens the arteriovenous anastamoses located in the palm of the hand and 2) conductively warms the extremity thus effectively warming the blood flow to the body's core. The vital heat vH2 system is a portable and compact warming device which provides a non-invasive approach to warming patients during surgery.
The primary objective of this study is to determine if the Dynatherm Medical vitalHEAT (vH2) Temperature Management System is as effective as the forced-air warming Bair Hugger™ (Arizant Healthcare, Eden Prairie, MN) for maintenance of intraoperative body temperature in patients undergoing abdominal surgery under general anesthesia. The critical endpoints to be evaluated in making this determination are 1) % of subjects with an average intraoperative esophageal temperature of ≥ 36º C and 2) % of subjects with an initial post anesthesia care unit sublingual temperature of ≥ 36º C. Secondary objectives include 1) comparison of the core body temperatures @ 60 minutes post anesthesia induction, 2) comparison of temperature trends during surgery and 3) comparison of the subjects' post anesthesia care unit temperature trends and hypothermic symptoms such as shivering.
Conditions
- Hypothermia
Interventions
- DEVICE
-
Dynatherm Medical vitalHEAT Temperature Management System vH2
The vH2 system consists of a Control Unit containing the heating system and the vacuum generation pump which connects via an umbilical containing the fluid and vacuum tubing to the Warming Sleeve. The Control Unit also contains the user interface and alarm management systems. The disposable Warming Sleeve consists of a manifold attached to the warming pads and a polyurethane pouch (Vacuum Sleeve) that are placed over the patient's hand and forearm and secured with tape. The Warming Sleeve manifold contains connectors for the fluid and vacuum tubing contained in the umbilical.
- DEVICE
-
Bair Hugger™ (Arizant Healthcare, Eden Prairie, MN)
The Bair Hugger system is the current standard of care at Tampa General Hospital. It consists of a Temperature Management Unit that contains the heating element, the air circulating motor and the temperature control mechanisms. This unit connects via a hose to the operating room blankets. The Bair Hugger technology relies on heated air convection. Warm air is circulated evenly through the air space in the specially designed blanket, warming the skin surface as well as any insulating blankets placed over the Bair Hugger blanket.
Sponsors & Collaborators
-
Dynatherm Medical Inc.
collaborator INDUSTRY -
University of South Florida
lead OTHER
Principal Investigators
-
Enrico M Camporesi, M.D. · University of South Florida
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2009-02-28
- Primary Completion
- 2009-07-31
- Completion
- 2009-08-31
Countries
- United States
Study Locations
More Related Trials
-
Comparison of Forced Air and Conductive Patient Heating Systems During Ambulatory Surgeries
NCT02467777 ·Status: COMPLETED ·Phase: NA
-
Perioperative Temperature Management
NCT00617136 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Core Body Temperature When Using Forced Air Warming or an Active Blanket to Prevent Perioperative Hypothermia
NCT02079311 ·Status: COMPLETED ·Phase: NA
-
Perioperative Active Warming Techniques in Colorectal Surgeries
NCT00913978 ·Status: TERMINATED ·Phase: NA
-
Thermal Compression Device for Maintenance of Perioperative Normothermia
NCT02155400 ·Status: COMPLETED ·Phase: NA
-
The Effects of Ambient Temperature and Forced-air Warming on Intraoperative Core Temperature
NCT02715076 ·Status: COMPLETED ·Phase: NA
-
WarmSmart Warming Protocol
NCT02812069 ·Status: WITHDRAWN ·Phase: NA
-
Efficacy of Warming Garment in the Perioperative Period With Integrated Chemical Heat Packs to Maintain Normothermia
NCT02905708 ·Status: COMPLETED ·Phase: NA
-
Circulating-water Garment With Forced-air Warming and Circulating-water Mattress During Abdominal Surgery
NCT00651898 ·Status: COMPLETED
-
Research on Intraoperative Hypothermia Risk Prediction Model and Temperature Management Strategy for Elderly Patients During Surgery Based on Dynamic Incremental Training
NCT06676735 ·Status: COMPLETED ·Phase: NA
-
Comparison of a New Patient Warming System Using Polymer Conductive Warming With Forced Air Warming During Surgery
NCT00772460 ·Status: COMPLETED ·Phase: PHASE3
-
Study to Evaluate Safety and Efficacy of Blanket Used to Prevent Anesthesia Induced Hypothermia
NCT01900067 ·Status: COMPLETED ·Phase: NA
-
Preventing Inadvertent Hypothermia in Patients Undergoing Major Spinal Surgery
NCT03193905 ·Status: COMPLETED ·Phase: NA
-
Prevention of Perioperative Hypothermia in Patients Submitted to Transurethral Resection
NCT03630887 ·Status: COMPLETED ·Phase: NA
-
Heated Humidification System Breathing Circuit for Maintenance of Body Temperature in Pediatric Patients
NCT03896867 ·Status: COMPLETED ·Phase: NA
-
Impact of Expanded Peri Operative Warming
NCT01649596 ·Status: COMPLETED ·Phase: NA
-
The Effect of Convective Pre-warming on Intra-operative Thermoregulatory Capabilities
NCT03876808 ·Status: TERMINATED ·Phase: NA
-
Prevention of IPH: Electric Warming Mattress vs Forced Air Warming Blanket
NCT01056991 ·Status: COMPLETED ·Phase: NA
-
Comparison of Vital HEAT (vH2) Temperature Management System to Upper-body Forced-air Warming
NCT00815191 ·Status: COMPLETED ·Phase: NA
-
Prewarming Effect in Preventing Perioperative Hypothermia
NCT02422758 ·Status: UNKNOWN ·Phase: PHASE3
-
Determination of Core Body Temperature in Parturient Warmed With Upper or Underbody Forced Air Cover (Bair Hugger)
NCT05314075 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Non-invasive Heat-flux and Invasive Core Temperature Monitoring
NCT03368040 ·Status: COMPLETED
-
Comparison of Active and Passive Perioperative Warming Techniques in Reducing Intraoperative Blood Loss
NCT02214524 ·Status: UNKNOWN ·Phase: NA
-
Comparing Hypothermic Temperatures During Hemiarch Surgery
NCT02860364 ·Status: RECRUITING ·Phase: NA
-
Perioperative Hypothermia in Patients Submitted to Transurethral Resection
NCT03527329 ·Status: COMPLETED