Gas Supply, Demand and Middle Ear Gas Balance: Specific Aim 3a Part ii
NCT00494364 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 28
Last updated 2017-11-13
Summary
The middle ear is an airspace located behind the eardrum that consists of two connecting compartments. The compartment directly behind the eardrum is called the tympanum and contains the three small bones of the middle ear, the hammer, anvil and stapes, that function to transfer eardrum movements to the inner ear so that you can hear. Behind the tympanum is the mastoid cavity which is a larger airspace subdivided into small air cells of unknown function. For normal hearing, it is important that the air pressure in the middle ear is similar to that of the environment so that the eardrum can move freely in response to sounds. The air pressure of the environment is not constant and is affected by changes in weather conditions (high and low pressure systems that move through the area) and by changes in elevation above sea level (the fullness in your ears that can be noticed when you ride in an elevator or in an airplane). The air pressure in the middle ear also changes because middle ear gas is constantly leaking from that airspace to the blood that flows through the walls of the middle ear. These effects (changing environmental air pressures and changing middle ear air pressure) are independent and cause the middle ear and environmental pressures to be different from each other. Periodically and during swallowing or yawning, any existing difference between middle ear and environmental air pressure is reset to zero by the opening of a biological tube (the Eustachian tube) that connects the middle ear to the back of the nose. This allows gas flow between the middle ear and the environment which increases or decreases middle ear pressure to the level in the environment at that time. Most people cannot open their Eustachian tubes at will and the number of automatic openings varies from infrequent to often in a population. Whether or not a person's usual frequency of Eustachian openings is good enough to keep the middle ear pressure the same as environmental levels depends on how fast gas is lost from the middle ear by gas leakage (diffusion) to blood. For example, in ears with very slow rates of gas loss, the Eustachian tube does not need to open very frequently to keep the middle ear at environmental pressure. Some researchers believe that the mastoid compartment functions to control the rate of gas loss to blood, with larger mastoid volumes associated with lesser rates of middle ear gas loss. In this experiment, the investigators plan to test this by measuring mastoid and tympanum volumes using Computer tomography (CT) and the rate of blood to middle ear gas transfer using a technique that involves breathing air that contains laughing gas (Nitrous Oxide=N2O) and measuring middle ear pressure change using tympanometry (a technique that involves putting an ear plug into the ear canal and measuring the pressure). From past studies in patients undergoing short surgical or dental procedures, the investigators know that breathing gas mixtures that contain N2O will increase the blood levels of that gas, cause gas to go from blood to the middle ear and increase middle ear pressure. The investigators predict that the rate of change in middle ear pressure while breathing a gas mixture containing 25% N2O and the normal oxygen level (20%) of air will be less for those ears with larger mastoid volumes. If the investigators prediction is correct, they will be able to explain why ears with larger mastoid volumes are better able to keep their pressure like that of the environment even if the Eustachian tube does not open often.
Conditions
- Healthy
Sponsors & Collaborators
-
National Institute on Deafness and Other Communication Disorders (NIDCD)
collaborator NIH -
University of Pittsburgh
lead OTHER
Principal Investigators
-
William J Doyle, PhD · University of Pittsburgh
-
J. Douglas Swarts, PhD · University of Pittsburgh
Eligibility
- Min Age
- 18 Years
- Max Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2007-06-30
- Primary Completion
- 2010-10-31
- Completion
- 2010-10-31
Countries
- United States
Study Locations
More Related Trials
-
Establish a Concordance Between the Mismatch Negativity Amplitude and a Score of Logatoms Discrimination
NCT03025386 ·Status: TERMINATED ·Phase: NA
-
Risk Factors and Potential Causes of Eustachian Tube Dysfunction in Adults
NCT01251432 ·Status: COMPLETED
-
Middle Ear Pressure Disregulation After Tympanostomy Tube Insertion
NCT00393900 ·Status: COMPLETED
-
Audiometric Parameters in Conductive Hearing Loss and Middle Ear Disease
NCT00222417 ·Status: UNKNOWN
-
Cochlear Implant Electrostimulation and the Influence on the Vestibular Organ
NCT05073796 ·Status: COMPLETED ·Phase: NA
-
Vestibular Function After Cochlear Implantation Using Soft Surgery Techniques
NCT02503592 ·Status: COMPLETED ·Phase: NA
-
Performance of a Hearing Aid Platform Including Different Styles of Hearing Aids
NCT02298452 ·Status: COMPLETED ·Phase: NA
-
Comparison in New Cochlear Implanted Subjects of a Tonotopy-based Fitting With or Without Fine Structure Coding
NCT05754918 ·Status: COMPLETED ·Phase: NA
-
Improved Speech Recognition Performance in Noise by Encoding Binaural Spatial Cues to the Cochlear Implant User.
NCT04357704 ·Status: WITHDRAWN ·Phase: NA
-
AB-Intra- and Post-Operative Measures of Auditory Function
NCT03685461 ·Status: COMPLETED ·Phase: NA
-
Real-Ear Measurement (REM) and Test Box System Integration Into Fitting Software
NCT02555462 ·Status: COMPLETED ·Phase: NA
-
Study of Sound and Speech Perception in New Cochlear Implanted Subjects Using or Not an Anatomy-based Fitting
NCT05230498 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Benefits of Bilateral Fitting in BAHS Users
NCT04006132 ·Status: COMPLETED ·Phase: NA
-
Collection of Clinical Data and Specimens for Research in Hearing, Balance, Taste, Smell, Voice, Speech, and Language Disorders.
NCT05670496 ·Status: RECRUITING
-
Early Experience of a New Implant System for Bone Conduction Hearing in the Pediatric Population
NCT03509974 ·Status: COMPLETED ·Phase: NA
-
Electric Pace-pitched Hearing Achieves Natural Tonotopy
NCT03892941 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Prognostic Factors in Tympanoplasty
NCT03416725 ·Status: UNKNOWN
-
Ph.D.-Project: Eustachian Tube Dysfunction: Causes, Diagnosis, Treatment, and Prognosis
NCT05055115 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Actual Maximum Gain in Bone Anchored Devices
NCT07294976 ·Status: RECRUITING ·Phase: NA
-
Peripheral and Central Influences on Auditory Temporal Processing & Speech Perception in Older Cochlear Implantees
NCT05554692 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Association Between Severe-to-profound Hearing Loss and the Balance Function of the Inner Ear
NCT05500521 ·Status: COMPLETED
-
Characterisation of Low Frequency Hearing and Vestibular Function in Patients Undergoing Cochlear Implantation
NCT06021132 ·Status: ACTIVE_NOT_RECRUITING
-
Voice Guard Processing Evaluation in a Cohort of Subjects Implanted With the Neuro Cochlear Implant System
NCT03256097 ·Status: COMPLETED ·Phase: NA
-
The Accuracy of Tests of Eustachian Tube Function
NCT02385175 ·Status: COMPLETED
-
Clinical Utility of Residual Hearing in the Cochlear Implant Ear
NCT04707885 ·Status: RECRUITING ·Phase: NA