Out-of-hospital Cardiopulmonary Resuscitation and AED Feedback
NCT00449969 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 312
Last updated 2011-04-22
Summary
The purpose of this study is to determine whether an online automatic feedback improved CPR quality (No-flow time, compression depth, short-term survival and one year follow up) in this prospective randomised study of out-of-hospital cardiac arrest
Conditions
- Cardiac Arrest
- Resuscitation
Interventions
- DEVICE
-
Zoll AED pro
Arm one (Extended feedback) offers full feedback guidance during CPR
- DEVICE
-
Zoll AED pro
In arm two (limited feedback) feedback is modified lacking several elements of feedback
Sponsors & Collaborators
-
University Hospital Muenster
lead OTHER
Principal Investigators
-
Thomas P Weber, MD · Department of Anesthesiology and Intensive Care, University Hospital Muenster
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2007-04-30
- Primary Completion
- 2009-04-30
- Completion
- 2010-12-31
Countries
- Germany
Study Locations
More Related Trials
-
How to Learn Cardiopulmonary Resuscitation
NCT04039997 ·Status: COMPLETED ·Phase: NA
-
Pre-arrival Instructions Effect on Bystander Cardiopulmonary Resuscitation (CPR).
NCT02007499 ·Status: COMPLETED
-
The Effect of T-CPR on the Quality of CPR and AED Use
NCT03690102 ·Status: COMPLETED ·Phase: NA
-
Application of Mechanical Cardiopulmonary Resuscitation Devices and Their Value in Out-of-hospital Cardiac Arrest: A Retrospective Analysis of the German Resuscitation Registry
NCT02932124 ·Status: COMPLETED
-
CPR Quality and Use of Feedback for OHCA
NCT04152252 ·Status: COMPLETED
-
CPR Feedback Devices
NCT02293200 ·Status: UNKNOWN ·Phase: NA
-
Quality of Cardiopulmonary Resuscitation Guided by AED vs Telephone-assistance
NCT03771911 ·Status: COMPLETED ·Phase: NA
-
Lowlands Saves Lives: A Randomized Trial Comparing CPR-quality Between Face-to-face vs. Lifesaver VR Training
NCT04013633 ·Status: COMPLETED ·Phase: NA
-
Effect of Capnography Feedback During Cardiopulmonary Resuscitation (CPR ) on Patient's Outcome
NCT02045498 ·Status: COMPLETED ·Phase: NA
-
The Impact of Aortic Valve Compression During Cardio-pulmonary Resuscitation on Patients With Out-of-hospital Cardiac Arrest
NCT05932784 ·Status: COMPLETED
-
Comparison of Manual Cardiopulmonary Resuscitation (CPR) Versus Automatic CPR Machine During Ambulance Transport.
NCT00308815 ·Status: UNKNOWN ·Phase: NA
-
MIHS Emergency Department CPR Quality Improvement Project
NCT01245699 ·Status: COMPLETED ·Phase: NA
-
Pediatric Resuscitation With Feedback Devices
NCT02294721 ·Status: UNKNOWN ·Phase: NA
-
Extracorporeal Membrane Oxygenation Effect in Prolonged Cardiopulmonary Resuscitation
NCT00173615 ·Status: COMPLETED
-
Evaluation of eCPR Survivors
NCT05339854 ·Status: UNKNOWN
-
Quantitative Measurement of Cardiopulmonary Resuscitation (CPR) During In Hospital Cardiac Arrest
NCT00628693 ·Status: COMPLETED
-
The Effect of a Real-time Audiovisual Feedback System on CPR Quality
NCT03902873 ·Status: COMPLETED ·Phase: NA
-
Pediatric Resuscitation With Feedback CPR Devices
NCT02281903 ·Status: COMPLETED ·Phase: NA
-
Improving CPR Quality With Longitudinal Practice and Realtime Feedback - RCT With CEA
NCT02539238 ·Status: UNKNOWN ·Phase: NA
-
Treatment Outcome in Patients After eCPR
NCT07031466 ·Status: COMPLETED
-
Standard CPR Versus Chest Compressions Only
NCT04569812 ·Status: COMPLETED ·Phase: NA
-
The Holistic Health Care of Post-Cardiac Arrest Survivors: From Patient's Health to Family Resilience
NCT04859270 ·Status: RECRUITING
-
Evaluation of Efficacy of Online Real-time Home CPR Training Program
NCT05023616 ·Status: COMPLETED ·Phase: NA
-
Multifaceted Intervention for Increasing Performance of CPR by Laypersons in Out-of-hospital Cardiac Arrest
NCT03633370 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Pediatric Resuscitation
NCT02283034 ·Status: UNKNOWN ·Phase: NA