Comparison of Airway Clearance Efficacy of Two High Frequency Chest Wall Oscillation (HFCWO) Devices in Cystic Fibrosis

NCT00308958 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15

Last updated 2013-05-30

No results posted yet for this study

Summary

Patients with cystic fibrosis (CF) must perform daily bronchial drainage therapy (BD) to keep their airways clear of secretions. Many different techniques are available to achieve this and there is currently no agreement as to which form of therapy is most effective. High frequency chest wall oscillation (HFCWO is used for this purpose by CF patients throughout the United States and abroad. To perform this therapy, the patient wears a vest which fits over the entire torso and is connected to an air compressor. The compressor generates oscillating air pulses that are transmitted to the lungs, thereby mobilizing secretions. The oscillations produced by the most commonly used device have a sinusoidal wave form (The Vest™ Airway Clearance System, Hill-Rom Inc, St Paul, MN). Previous studies indicate this form of therapy is as effective as more traditional and cumbersome forms of therapy. The design of the pulse generator has been recently modified so that the oscillations produced have a triangular wave form (Respitech Inc, MN). Studies done at the University of Minnesota found that the air flows induced in the airways can vary substantially depending on the wave form applied to the chest. At present, the impact of using a triangular wave form on mucus removal is unknown. The proposed study will compare mucous clearance using a device generating sine wave oscillations to a device generating triangular wave oscillations.

Hypothesis: Bronchial drainage using a triangular wave form of HFCWO will result in superior sputum production compared to HFCWO using a sine wave form.

Secondary Hypotheses:

Bronchial drainage using a triangular wave form of HFCWO may result in sputum with rheologic properties distinct from sputum produced while using sine wave HFCWO.

Bronchial drainage using a triangular wave form of HFCWO may result in superior post-therapy pulmonary function tests compared to pulmonary function tests obtained following therapy with sine wave HFCWO.

Subjects will perceive bronchial drainage using a triangular wave form of HFCWO as more comfortable than airway clearance using sine wave HFCWO.

Conditions

Interventions

DEVICE

High frequency chest wall oscillator

Sponsors & Collaborators

Principal Investigators

  • Robert R Kempainen, MD · University of Minnesota

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
CROSSOVER

Eligibility

Min Age
19 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2006-02-28
Primary Completion
2006-08-31
Completion
2006-08-31

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT00308958 on ClinicalTrials.gov