Comparative Study of the Tomey FT-1000, and Goldmann Applanation Tonometer (GAT)
NCT07804277 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2026-09-04
Summary
This study is intended to evaluate the agreement between IOP measurements obtained with the FT-1000 non-contact tonometer and a GAT to confirm the feasibility of the measurement procedures.
This is a prospective comparative study that will be conducted at one clinical site in the United States. Subjects who sign an informed consent form and fulfill all inclusion and exclusion criteria will undergo FT-1000 measurements followed by Goldmann applanation tonometry during a single study visit.
The primary analysis will be performed using one preselected study eye from each subject. Measurements from the fellow eye, when available, may be summarized as exploratory analyses but will not contribute to the primary effectiveness analysis.
In general, descriptive statistics (n, mean, standard deviation, median, minimum and maximum) will be used to summarize continuous variables. Frequencies and percentages will be used to summarize categorical variables. The number of accepted scans and the total number of scans evaluated will be summarized by scan type, device, and subject population.
Agreement between the FT-1000 and the Goldmann applanation tonometer will be evaluated using the study eye measurements by calculating the mean difference, standard deviation (SD), 95% limits of agreement (LOA), Bland-Altman plots, Deming regression, and Pearson correlation coefficient.
Exploratory analyses may also be performed using fellow-eye measurements.
Conditions
Interventions
- DEVICE
-
Non Contact Tonometer and Applanation Tonometer
Intraocular pressure measurement by non-contact tonometer and applanation tonometer.
Sponsors & Collaborators
-
Tomey Corporation
lead INDUSTRY
Eligibility
- Min Age
- 22 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-09-24
- Primary Completion
- 2026-09-28
- Completion
- 2026-09-28
- FDA Device
- Yes
More Related Trials
-
GAT-DCT-Discordance Due to Corneal Properties
NCT01474070 ·Status: COMPLETED
-
Comparison of Intraocular Pressure Measurement With the Novel TonoVera Device With Other Commonly Used Devices
NCT05523622 ·Status: RECRUITING ·Phase: NA
-
Assessment of Home Tonometry in Glaucoma
NCT03057301 ·Status: COMPLETED
-
ICare Self-tonometry - A Head-to-head Comparison to the Gold Standard Goldmann Tonometer
NCT01733550 ·Status: UNKNOWN
-
iCare vs Tonopen vs Goldmann Applanation Post-vitrectomy Surgery
NCT01786954 ·Status: COMPLETED ·Phase: NA
-
TRK-3 Conformance to Standards for Tonometers
NCT06247072 ·Status: COMPLETED
-
Comparison of Intraocular Pressure Measurements Between Reichert Tono-Vera Tonometer and Goldmann Tonometry
NCT04360369 ·Status: COMPLETED ·Phase: NA
-
iCare® Home vs Goldmann Applanation Tonometry
NCT04911387 ·Status: COMPLETED
-
24h Continuous Intraocular Pressure (IOP) Monitoring vs Goldmann Applanation Tonometry
NCT01217853 ·Status: COMPLETED
-
Clinical Evaluation of CATS Tonometer Prism
NCT02990169 ·Status: COMPLETED ·Phase: NA
-
Precision of the Icare200 for Measuring Intraocular Pressure
NCT05147610 ·Status: COMPLETED ·Phase: NA
-
Study to Compare Standard Perimetry With the New Scotoma-Oriented Perimetry (SCOPE) Using a New Fast German Adaptive Threshold Estimation (GATE) in Glaucoma Patients
NCT00902109 ·Status: UNKNOWN
-
Comparison of Goniotomy Device Outcomes in Combined Phacoemulsification-goniotomy Surgeries
NCT07418853 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effect of Central Corneal Thickness On IOP Using Various Tonometers
NCT00570791 ·Status: COMPLETED
-
Intraocular Pressure Measured by a Novel Sensing Contact Lens Versus Tonometry
NCT04024293 ·Status: RECRUITING ·Phase: NA
-
Impact of Home Intraocular Pressure Telemonitoring on Intraocular Pressure Control and Glaucoma Progression
NCT05940623 ·Status: RECRUITING ·Phase: NA
-
A Comparison of Two Ab Interno Procedures in the Treatment of Glaucoma in Patients Undergoing Cataract Extraction
NCT02784249 ·Status: COMPLETED ·Phase: NA
-
Prospective Comparative Clinical Study to Investigate the Use of the NON CONTACT TONO/PACHYMETER NT-530P
NCT01621503 ·Status: COMPLETED ·Phase: NA
-
Corneal Biomechanics and Continuous IOP Monitoring Using Soft Contact Lenses in Glaucomatous Patients
NCT01849536 ·Status: COMPLETED ·Phase: NA
-
Different Glaucoma Treatments Effect on Intraocular Pressure Fluctuation With Postural Change in Eyes With Open-angle Glaucoma
NCT02868502 ·Status: UNKNOWN
-
Study Comparing Quantitative Assessments in Open-angle Glaucoma (OAG) and/or Ocular Hypertension (OHT)
NCT01540370 ·Status: COMPLETED
-
Baerveldt (BGI) Valve Versus Ahmed(AGV) Valve in Management of Difficult Glaucoma Cases
NCT04215575 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Handheld Rebound Tonometer and Applanation Tonometer in IOP Measurement in Paediatric Glaucomas
NCT06766799 ·Status: NOT_YET_RECRUITING
-
Modified Trabeculectomy After Failure of Combined Phaco With GATT
NCT07455786 ·Status: RECRUITING ·Phase: NA
-
Implantable Intraocular Pressure Sensor for Glaucoma Monitoring in Patients With Boston Keratoprosthesis Type 1
NCT03421548 ·Status: WITHDRAWN ·Phase: NA