Non-invasive Saphenous Nerve Stimulation Therapy for Overactive Bladder
NCT07780786 · Status: NOT_YET_RECRUITING · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 290
Last updated 2026-08-24
Summary
The goal of this clinical trial is to study the NiNA System and how it works to treat overactive bladder. Up to 290 participants will be enrolled in the study in the USA and Australia.
The investigational NiNA System includes a wearable neurostimulator device ("NiNA" or "Device"), a flexible wrap to secure the Device to the calf during treatment of the saphenous nerve (SAFN), with smartphone-based control application with patient support features that allow users to control the stimulation therapy and receive reminder on days they are supposed to provide therapy ("NiNA App") or an enhanced smartphone-based control application which also has patient support features and educational multi-media content ("NiNA Care App").
The main questions the study aims to answer are: 1) How does the NiNA system compare to a common overactive bladder (OAB) medication; 2) How well does the NiNA system improve overactive bladder symptoms; and, 3) Does the NiNA system produce any unwanted side-effects.
In the study half the participants randomly receive the NiNA system and the other half first receive the OAB medication and later are treated with the NiNA System.
The Participants in the investigative Device arm (NiNA) will:
Provide NiNA system treatments very day for 30 minutes during a 28 day induction/restore period. This is followed by maintenance treatments (30 minutes, 3-times a week) until 12 weeks, when the primary endpoint data are measured. Participants continue maintenance (30 minutes, 3-times a week) for the remaining 52 weeks of the study.
Participants in the OAB medication arm will:
Take a capsule every day (tolterodine tartrate extended release (ER) 4 mg) for twelve weeks.
At 12 weeks, OAB medication arm Participants will stop taking the OAB medication and cross-over to treatment with the NiNA system. One-third of the cross-over Participants will be use a phone-based software application that allows them to control the neurostimulator and receive reminders on days the are scheduled to provide their therapy (NiNA App) and the other two-thirds of the cross-over Participants will use a phone based software application that also contains educational videos that reinforce the therapy (NiNA Care App). Assignment to each arm is random.
The study will measure primary and secondary endpoints completely remotely using digital questionnaires that are presented to Participants on a specialized software application installed on their phones ("Study App"):
Changes in OAB symptoms at a defined set of time points using the following instruments:
1. Bladder diary (3-day, consecutive);
2. Self-administered and validated Quality-of-Life questionnaires (see Effectiveness Assessments);
3. Additional assessments of participant satisfaction and preferences will be obtained using participant study surveys and questionnaires at defined study time points.
Conditions
- Overactive Bladder (OAB)
Interventions
- DEVICE
-
Wearable neurostimulation system for saphenous nerve stimulation
Device: NiNA System The NiNA System includes a wearable neurostimulator device and stimulation matrix with 6 conductive pads that provide transcutaneous stimulation ("NiNA"), that are secured to the upper calf during treatment using a flexible wrap. The system includes a either a) a basic version smartphone-based control application with patient support features ("NiNA with NiNA App") or a more advanced version which also includes multi-media educational content ("NiNA with NiNA Care App"). The system uses field steering controls to improve targeted electrical stimulation of the saphenous nerve.
- DRUG
-
tolterodine tartrate 4 mg extended release
once daily tolterodine tartrate 4mg ER
Sponsors & Collaborators
-
NinaMED Pty Ltd
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-09-10
- Primary Completion
- 2027-12-10
- Completion
- 2028-01-30
- FDA Drug
- Yes
- FDA Device
- Yes
Countries
- United States
- Australia
Study Locations
More Related Trials
-
Clinical Study to Evaluate the Treatment Effect and Safety of BAY1817080 in Patients With Overactive Bladder (OAB)
NCT04545580 ·Status: COMPLETED ·Phase: PHASE2
-
Validation of Instruments for Pragmatic Clinical Trials for Overactive Bladder
NCT01925456 ·Status: COMPLETED ·Phase: PHASE1
-
Comparing Number of Injection Sites of In-office Intravesical Onabotulinumtoxin A Treatments for Overactive Bladder: A Randomized Controlled Trial
NCT05157295 ·Status: UNKNOWN ·Phase: PHASE4
-
A Study to Examine the Safety and Efficacy of a New Drug in Patients With Symptoms of Overactive Bladder (OAB)
NCT03492281 ·Status: COMPLETED ·Phase: PHASE3
-
Reduction of Bladder Injection Pain With Belladonna Opiate Suppository
NCT02600715 ·Status: COMPLETED ·Phase: PHASE4
-
BOTOX® Intravesical Instillation in Participants With Overactive Bladder and Urinary Incontinence
NCT03320850 ·Status: COMPLETED ·Phase: PHASE2
-
Instillation of Botox in the Bladder in Women With Overactive Bladder (OAB)
NCT02735499 ·Status: COMPLETED ·Phase: PHASE2
-
Combined Anticholinergic Medication and Sacral Neuromodulation to Treat Refractory Overactive Bladder
NCT01047046 ·Status: COMPLETED
-
A Prospective, Observational, Multicenter Study of Patients Following Initiation of a New Course of Treatment for Overactive Bladder (OAB)
NCT02386072 ·Status: COMPLETED
-
Evaluation of the TheraNova Neuromodulation System for the Treatment of Overactive Bladder Symptoms
NCT04758247 ·Status: COMPLETED ·Phase: NA
-
BlueWind RENOVA iStim™ System for the Treatment of OAB
NCT03596671 ·Status: COMPLETED ·Phase: NA
-
A Study Measuring and Tracking Changes in Overactive Bladder (OAB) Medication
NCT01317810 ·Status: WITHDRAWN
-
Clinical Trial of Sacral Neuromodulation for Treatment of Refractory Overactive Bladder (OAB)
NCT02619721 ·Status: UNKNOWN ·Phase: EARLY_PHASE1
-
Pilot Trial in Sleep Laboratory Setting to Compare the Physiology of Night Time Bladder Function in Subjects With Overactive Bladder (OAB) Versus Subjects That Have Insomnia and Healthy Normal Subjects
NCT01029015 ·Status: COMPLETED
-
SVT-40776 in Patients Suffering From Overactive Bladder Syndrome
NCT00507169 ·Status: COMPLETED ·Phase: PHASE2
-
A Therapeutic Exploratory Clinical Study of DA-8010 in Patients With Overactive Bladder
NCT03566134 ·Status: COMPLETED ·Phase: PHASE2
-
Self-Start Triage Model for Post-Botox® Lower Urinary Tract Symptoms
NCT07648290 ·Status: RECRUITING ·Phase: EARLY_PHASE1
-
Safety and Tolerability of TAR-302-5018 in Subjects With Idiopathic Overactive Bladder
NCT03109379 ·Status: COMPLETED ·Phase: PHASE1
-
Intradetrusor Botulinum Toxin A for OAB Via 1 Versus 10 Injections: A Randomized Clinical Trial
NCT05308979 ·Status: COMPLETED ·Phase: PHASE4
-
Study to Evaluate the Efficacy, Safety, and Tolerability of Mirabegron in Older Adult Subjects With Overactive Bladder (OAB)
NCT02216214 ·Status: COMPLETED ·Phase: PHASE4
-
InSite for Over Active Bladder
NCT00547378 ·Status: COMPLETED ·Phase: PHASE4
-
A Study to Evaluate the Efficacy of Tolterodine on Specific Symptoms in Adult Patients With Overactive Bladder.
NCT00645281 ·Status: COMPLETED ·Phase: PHASE4
-
RELIEVE Study: NT 201 Intravesical Administration Using Vibe System (ViXe Combination Product) for the Treatment of Idiopathic Overactive Bladder
NCT07553065 ·Status: RECRUITING ·Phase: PHASE2
-
Assessment of Patient-reported Goal Attainment in the Treatment of Female Overactive Bladder
NCT00836381 ·Status: COMPLETED ·Phase: PHASE4
-
Sanctura Muscarinic Receptor Antagonist Resists Transport (SMART) Trial
NCT00863551 ·Status: COMPLETED ·Phase: PHASE4