Safety, Tolerability, and Accuracy of a Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults
NCT07770178 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-08-18
Summary
The occurrence and progression of eye diseases like glaucoma are closely related to intraocular pressure fluctuations. Traditional single-point intraocular pressure measurement methods cannot reflect daily dynamic changes and are prone to missing hidden intraocular pressure peaks, limiting precise diagnosis and individualized treatment. This project aims to evaluate the wearing safety and measurement accuracy of a new low-modulus, high-strength hydrogel wearable dynamic intraocular pressure sensor. This product adopts the form of smart contact lenses, fully embedding a micro sensor into a hydrogel lens, combined with an external antenna mount and a portable recorder to continuously detect and wirelessly record even slight changes in corneal curvature, thereby obtaining real-time intraocular pressure fluctuation trend data. Based on this, the objective of this study is to evaluate the safety, measurement accuracy and tolerabilityof a wearable dynamic intraocular pressure sensor based on a novel hydrogel in healthy volunteers.
Conditions
- Intraocular Pressure
Interventions
- DEVICE
-
Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor
The investigational device is a wearable hydrogel-based contact lens sensor designed to record electrical signals associated with changes in intraocular pressure. The CLS is worn on the study eye and allowed to stabilize for 10 minutes before signal acquisition. Sensor signals are obtained at three predefined measurement points and compared with Goldmann applanation tonometry measurements to assess measurement accuracy.
Sponsors & Collaborators
-
Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 20 Years
- Max Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-08-30
- Primary Completion
- 2026-11-30
- Completion
- 2027-02-18
Countries
- China
Study Locations
More Related Trials
-
Somnotouch-NIBP Compared to Standard Ambulatory 24 Hours Blood Pressure Measurement
NCT03054688 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03049709 ·Status: COMPLETED
-
Intraocular Pressure Accuracy and Variability of the Barraquer Tonometer
NCT00409669 ·Status: UNKNOWN ·Phase: NA
-
Clinical Feasibility of a Conformal Ultrasound Blood Pressure Sensor
NCT05909605 ·Status: COMPLETED
-
Non-Invasive Blood Pressure Measurement in Critically Ill PAtients Post Cardiosurgical Therapy
NCT03710473 ·Status: COMPLETED
-
Non-invasive Monitor in Endoscopic Invasive Procedure
NCT03292627 ·Status: COMPLETED
-
Using Laser Spatiotemporal Photoplethysmogram and Computational Method for Management of Chronic Disorders.
NCT06717646 ·Status: RECRUITING
-
Comparison of Continuous Non-Invasive and Invasive Intracranial Pressure Measurement
NCT01863381 ·Status: TERMINATED ·Phase: NA
-
Evaluating Effectiveness of Elevated Intra-abdominal Pressure (IAP) by PressureDOT
NCT06709924 ·Status: COMPLETED
-
Comparisonbetween Primary Hypertension Monitoring Methods for Detection of Early Kidney Dysfunction
NCT03491813 ·Status: UNKNOWN
-
The Water Drinking Test in Glaucoma Study
NCT05283031 ·Status: COMPLETED
-
Evaluation of a Novel Mobile Phone Application ( OptiBP) for Blood Pressure Monitoring
NCT04121624 ·Status: COMPLETED
-
Validation of Wrist Type Oscillometric Blood Pressure Monitorings
NCT04633785 ·Status: UNKNOWN
-
Evaluation of Intraocular Pressure Following a Vitreoretinal Surgery Using Goldmann Applanation Tonometry, Icare and Accupen
NCT06522867 ·Status: RECRUITING ·Phase: NA
-
Intracranial Pressure Monitoring in Moderate Traumatic Brain Injury
NCT04900168 ·Status: UNKNOWN
-
Is Continuous Non-Invasive Monitoring Accurate When Used on the Lower Extremity: Finger Vs Toe?
NCT06805435 ·Status: COMPLETED
-
Optical System to Continuously Measure Arterial Blood Pressure
NCT02651558 ·Status: COMPLETED ·Phase: NA
-
Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03046264 ·Status: COMPLETED
-
Water Drinking Test During Intraocular Pressure Fluctuation (IOP) Monitoring
NCT01362868 ·Status: TERMINATED ·Phase: NA
-
Automated Applanation Tonometry - Updated
NCT07298356 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Continuous Non Invasive Blood Pressure With Adult Volunteers
NCT04876664 ·Status: UNKNOWN ·Phase: NA
-
The vPPG-detecting Software Guided Management of Cirrhotic Portal Hypertension
NCT04786782 ·Status: UNKNOWN
-
Non-contact Blood Pressure and SpO2 Measurement Based on Image Sensor
NCT06204822 ·Status: RECRUITING
-
Comparison of Continuous Non-invasive Pressure Device Versus Invasive Pressure Measurement During Prehospital Emergency
NCT01627470 ·Status: UNKNOWN
-
Validation of the Blood Pressure Monitoring Function
NCT06104501 ·Status: NOT_YET_RECRUITING