Miniature In-line Respirator
NCT07768215 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 5
Last updated 2026-09-04
Summary
This first-in-human pilot study will test an investigational miniature breathing device called the Hope inVent. The device is a small, single-use, in-line respirator that connects to a breathing tube and uses compressed oxygen to help move air in and out of the lungs. It has no moving parts and is designed to provide short-term breathing support in situations where standard ventilators may not be available, such as emergencies, disasters, battlefield settings, transport, or ventilator shortages.
The study will enroll up to 5 brain-dead organ donors who are already receiving mechanical ventilation at the Gift of Life Donor Care Center at the Hospital of the University of Pennsylvania. Donors will only be included after authorization for organ donation and research has been obtained through standard procedures. Donors who may donate lungs or who have significant lung disease will not be included.
During the study, investigators will briefly replace the standard ventilator with the Hope inVent device for up to 15 minutes. The standard ventilator will remain immediately available, and the donor will be continuously monitored by the clinical and research teams. Investigators will measure whether the device can maintain acceptable breathing measures, including oxygen level and carbon dioxide level. They will also record breathing pressures and tidal volume, which is the amount of air delivered with each breath. If the device does not perform as expected or if any safety concern occurs, the donor will be returned immediately to the standard ventilator.
There is no direct benefit to the organ donor. Information from this study may help determine whether this type of simple, low-cost breathing device could be useful for future patients who need emergency or short-term ventilator support when standard ventilators are not available.
Conditions
- Brain Death
- Respiration, Artificial
Interventions
- DEVICE
-
Hope inVent
The Hope inVent is an investigational, single-use, miniature in-line respirator designed to provide short-term ventilatory support for intubated individuals. The device is a 3D-printed, pressure-cycled, gas-powered respirator with no moving parts. It connects to the endotracheal tube breathing circuit and uses compressed oxygen as its power source. In this study, only the Green Hope inVent model will be used. The device cycles between fixed pressure settings: peak inspiratory pressure of 18 cm H2O and positive end-expiratory pressure of 6 cm H2O. Enrolled brain-dead research donors will be placed on the device once for up to 15 minutes, with continuous respiratory and physiologic monitoring. The donor will then be returned to the standard mechanical ventilator.
Sponsors & Collaborators
-
National Institutes of Health Clinical Center (CC)
lead NIH
Principal Investigators
-
Andrew J Mannes, M.D. · National Institutes of Health Clinical Center (CC)
Study Design
- Allocation
- NA
- Purpose
- DEVICE_FEASIBILITY
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 1 Year
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-09-09
- Primary Completion
- 2028-12-01
- Completion
- 2028-12-01
Countries
- United States
Study Locations
More Related Trials
-
Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure
NCT01680783 ·Status: COMPLETED ·Phase: NA
-
Efficacy of High-Flow Humidified Oxygen (HFHO) in Apneic Oxygenation for Apnea Testing: A Comparison With Continuous Positive Airway Pressure (CPAP)
NCT07640009 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Automated Oxygen Control by O2matic to Patients Admitted With Acute Hypoxemia
NCT04079465 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Oxymask and Oxy2mask on Supplemental Oxygen Delivery
NCT06433934 ·Status: WITHDRAWN ·Phase: NA
-
Helmet Noninvasive Ventilation vs. High-flow Nasal Cannula in Moderate-to-severe Acute Hypoxemic Respiratory Failure
NCT04502576 ·Status: COMPLETED ·Phase: NA
-
Inhaled Nitric Oxide in Severe Obesity
NCT06675435 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Helmet NIV vs. CPAP vs. High-flow Nasal Oxygen in Hypoxemic Respiratory Failure
NCT05089695 ·Status: RECRUITING ·Phase: NA
-
Oxygen Therapy During Acute Respiratory Failure in Immuno-compromised Patients
NCT02424773 ·Status: COMPLETED ·Phase: PHASE3
-
Oxygenation Efficacy of "Intrinseque Health" Non-Rebreathing Mask ("IHNRM")
NCT06310629 ·Status: RECRUITING ·Phase: NA
-
A New Portable Device for Non-invasive Ventilatory Support
NCT06716502 ·Status: RECRUITING ·Phase: NA
-
The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
NCT00783679 ·Status: WITHDRAWN ·Phase: NA
-
A Randomised Controlled Trial of High-Flow Nasal Oxygen Versus Standard Oxygen Therapy in Critically Ill Immunocompromised Patients
NCT02739451 ·Status: COMPLETED ·Phase: NA
-
Oxygenation by 100% Oxygen Via High Flow Nasal Cannula in Surgical Patients
NCT02706431 ·Status: COMPLETED ·Phase: NA
-
Prehospital High-Flow Nasal Oxygen Therapy
NCT03326830 ·Status: COMPLETED ·Phase: NA
-
Optiflow THRIVE for Delivery of Oxygen to Patients During Total Intravenous Anesthesia While Undergoing Radiology Procedures
NCT04171037 ·Status: COMPLETED ·Phase: NA
-
High Flow Oxygen and Non Invasive Ventilation for Hypercapnic Respiratory Failure
NCT03627598 ·Status: UNKNOWN ·Phase: NA
-
High Flow Nasal Oxygen Versus VNI in Acute Hypercapnic Cardiogenic Pulmonary Edema
NCT02874339 ·Status: UNKNOWN ·Phase: NA
-
O2matic Cardiology Protocol
NCT05452863 ·Status: COMPLETED ·Phase: NA
-
Aviation Portable Oxygen Delivery System
NCT03425409 ·Status: WITHDRAWN ·Phase: NA
-
High Pressure Non Invasive Ventilation in Hypercapnic Respiratory Failure
NCT04362787 ·Status: UNKNOWN
-
Biphasic Extrathoracic Cuirass Ventilation During Dental Treatment
NCT00420069 ·Status: WITHDRAWN
-
HFTO Via Tracheal Intubation in Neurocritical Patients
NCT07257016 ·Status: COMPLETED ·Phase: NA
-
Extracorporeal Membrane Oxygenation (ECMO) in Non-intubated Patients With Acute Respiratory Distress Syndrome (ARDS)
NCT01669863 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Early CPAP in COVID-19 Patients With Respiratory Failure.
NCT04326075 ·Status: COMPLETED ·Phase: NA
-
Comparison of High-flow Oxygen vs. BiPAP in Type II (Hypercapnic) Respiratory Failure
NCT03443479 ·Status: COMPLETED