Biodegradable Magnesium Screws for Unstable Ankle Fracture Surgery

NCT07693933 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 28

Last updated 2026-07-27

No results posted yet for this study

Summary

Ankle fractures are among the most common injuries that need surgery. When the broken bones make the ankle unstable, surgeons usually fix them with metal screws and plates. Metal hardware holds the bones in place well, but it can cause irritation, can loosen or break, and often has to be removed in a second surgery later.

This study looks at a different kind of screw called the RemeOs magnesium-based screw. It is made from a magnesium alloy and is designed to slowly dissolve and be absorbed by the body over about two to three years after it has done its job of holding the bone together. Because it dissolves on its own, patients may not need a second surgery to remove the hardware. These screws are authorized by the U.S. Food and Drug Administration (FDA) for use in medial malleolus ankle fractures. In this study, they are being used as an off-label indication.

The purpose of this study is to learn how well these magnesium screws work and how safe they are when used to repair unstable ankle fractures. The study will enroll at least 25 adults (ages 18 to 80) who have an unstable ankle fracture that needs surgery. All participants will have their fracture repaired with RemeOs screws as part of their normal surgical care.

After surgery, participants will be followed for 12 months. They will return for check-ups at about 6 weeks, 3 months, 6 months, and 12 months. At these visits, the study team will examine the ankle, take X-rays to see how the bone is healing and how the screws are dissolving, ask about any complications, and have participants fill out questionnaires about their ankle function and pain.

The main thing the study measures is ankle function at 12 months, scored using a standard ankle questionnaire (the Olerud-Molander Ankle Score). The study also tracks pain, healing on X-rays, how the screws break down over time, and any complications such as infection, loss of fixation, non-healing, or the need for additional surgery.

The surgery, X-rays, and follow-up visits in this study are the same care patients would receive whether or not they take part. The only research-specific parts are giving consent and filling out the study questionnaires. Taking part is voluntary and does not change the care a patient receives.

Conditions

  • Ankle Fractures
  • Syndesmotic Injury

Interventions

DEVICE

RemeOs Magnesium-Based Biodegradable Screw

ORIF performed using RemeOs magnesium-alloy biodegradable screws (Screw LAG, Screw COM, Screw FT, and/or Screw LAG Solid) for fixation of any malleolus and/or for syndesmotic fixation where indicated, per the device Instructions for Use. The screws provide mechanical stability during healing and gradually biodegrade over approximately 2-3 years, eliminating the need for routine hardware removal.

Sponsors & Collaborators

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-08-31
Primary Completion
2029-02-28
Completion
2029-03-31

Countries

  • United States