Biodegradable Magnesium Screws for Unstable Ankle Fracture Surgery
NCT07693933 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 28
Last updated 2026-07-27
Summary
Ankle fractures are among the most common injuries that need surgery. When the broken bones make the ankle unstable, surgeons usually fix them with metal screws and plates. Metal hardware holds the bones in place well, but it can cause irritation, can loosen or break, and often has to be removed in a second surgery later.
This study looks at a different kind of screw called the RemeOs magnesium-based screw. It is made from a magnesium alloy and is designed to slowly dissolve and be absorbed by the body over about two to three years after it has done its job of holding the bone together. Because it dissolves on its own, patients may not need a second surgery to remove the hardware. These screws are authorized by the U.S. Food and Drug Administration (FDA) for use in medial malleolus ankle fractures. In this study, they are being used as an off-label indication.
The purpose of this study is to learn how well these magnesium screws work and how safe they are when used to repair unstable ankle fractures. The study will enroll at least 25 adults (ages 18 to 80) who have an unstable ankle fracture that needs surgery. All participants will have their fracture repaired with RemeOs screws as part of their normal surgical care.
After surgery, participants will be followed for 12 months. They will return for check-ups at about 6 weeks, 3 months, 6 months, and 12 months. At these visits, the study team will examine the ankle, take X-rays to see how the bone is healing and how the screws are dissolving, ask about any complications, and have participants fill out questionnaires about their ankle function and pain.
The main thing the study measures is ankle function at 12 months, scored using a standard ankle questionnaire (the Olerud-Molander Ankle Score). The study also tracks pain, healing on X-rays, how the screws break down over time, and any complications such as infection, loss of fixation, non-healing, or the need for additional surgery.
The surgery, X-rays, and follow-up visits in this study are the same care patients would receive whether or not they take part. The only research-specific parts are giving consent and filling out the study questionnaires. Taking part is voluntary and does not change the care a patient receives.
Conditions
- Ankle Fractures
- Syndesmotic Injury
Interventions
- DEVICE
-
RemeOs Magnesium-Based Biodegradable Screw
ORIF performed using RemeOs magnesium-alloy biodegradable screws (Screw LAG, Screw COM, Screw FT, and/or Screw LAG Solid) for fixation of any malleolus and/or for syndesmotic fixation where indicated, per the device Instructions for Use. The screws provide mechanical stability during healing and gradually biodegrade over approximately 2-3 years, eliminating the need for routine hardware removal.
Sponsors & Collaborators
-
Bioretec Ltd.
collaborator INDUSTRY -
Massachusetts General Hospital
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-08-31
- Primary Completion
- 2029-02-28
- Completion
- 2029-03-31
Countries
- United States
Study Locations
More Related Trials
-
A Multicenter Randomized Trial Comparing Antiglide and Lateral Plate Fixation in Ankle Fractures
NCT00718302 ·Status: COMPLETED ·Phase: NA
-
RemeOs™ DrillPin for Fixation of Distal Radius Fractures in Children
NCT07028541 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Zimmer® MotionLoc® in Distal Tibia Fractures
NCT02717546 ·Status: COMPLETED
-
Functional Orthosis Versus Cast Immobilization for Partially Unstable Weber B Ankle Fractures
NCT05412693 ·Status: COMPLETED ·Phase: NA
-
Morphological Characteristics of Inferior Pole Patellar Fractures and a Finite Element Analysis Combined with a Retrospective Clinical Study of Anchor Suture and Titanium Cable Cerclage Treatment
NCT06736639 ·Status: COMPLETED
-
A Cohort Study of Bioabsorbable Screws for Syndesmosis Fixation Fixation in Ankle Fracture
NCT05662449 ·Status: COMPLETED
-
Randomized Controlled Trial Comparing Suture Button Versus Fibulink Fixation for Acute Ankle Syndesmosis Injuries
NCT05626036 ·Status: RECRUITING ·Phase: NA
-
Static Implant Versus Dynamic Implant in the Surgical Treatment on Ankle Syndesmosis Rupture
NCT01109303 ·Status: COMPLETED ·Phase: NA
-
Plating of Distal Femur Fractures by Far Cortical Locking Using MotionLoc Screws
NCT01667887 ·Status: COMPLETED
-
MotionLoc Study, Femur Fractures
NCT01612208 ·Status: COMPLETED
-
Treatment of Atrophic Nonunion Fractures by Autologous Mesenchymal Stem Cell Percutaneous Grafting
NCT01429012 ·Status: WITHDRAWN ·Phase: PHASE2
-
Fibular Fixation in Ankle Fractures:Plate Verses Nail.
NCT02507193 ·Status: COMPLETED ·Phase: NA
-
Comparing Function, Pain and Return to Work in Conservative Versus Surgical Treated Stable Lateral Malleolar Fractures
NCT03587571 ·Status: TERMINATED ·Phase: PHASE4
-
Biobased Polyester Versus Synthetic Fiberglass Casts for Treating Stable Upper Limb Fractures in Children
NCT06102603 ·Status: COMPLETED ·Phase: NA
-
Performance and Safety Follow-up of Bioabsorbable Headless Inion CompressOnTM Screws in the Fixation of Bone Fractures in Ankle, Knee and Elbow of Pediatric and Adolescent Patients
NCT07473947 ·Status: RECRUITING ·Phase: NA
-
Plate Versus Intramedullary Screw for Lateral Malleolus Fracture in Ankle Fracture Type A&B
NCT07447336 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Freeze-dried Bovine Hydroxyapatite/Secretome Composite for Bone Defects
NCT04980261 ·Status: UNKNOWN ·Phase: NA
-
Ankle Syndesmosis Fixation by Antibiotic Releasing Bioabsorbable Screw
NCT01729195 ·Status: COMPLETED ·Phase: PHASE2
-
Buried Intramedullary K-wire Fixation Compared With Plate and Screw Fixation for Metacarpal Fractures in Unstable Extra-Articular Metacarpal Fractures
NCT02718170 ·Status: TERMINATED ·Phase: NA
-
OIF/β-TCP in Patients With Open Tibial Fractures in Need of Bone Grafting
NCT04960722 ·Status: COMPLETED ·Phase: NA
-
Pilot Clinical Trial of CPC/rhBMP-2 Microffolds as Bone Substitute for Bone Regeneration
NCT02609074 ·Status: COMPLETED ·Phase: PHASE4
-
Comparative Study of Gene-activated Bone Substitute and Autobone in Treatment of Long Bone Nonunions
NCT04705857 ·Status: UNKNOWN
-
A Pilot Clinical Study to Evidence Safety and Efficacy of Fracture Fixation of the Distal Radius Using a Bioresorbable Bone Adhesive to Augment Metal Hardware
NCT07452536 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Microfracture vs. Microfracture and BMAC for Osteochondral Lesions of the Talus
NCT03856021 ·Status: UNKNOWN ·Phase: NA
-
Ziptight or Tricortical Screw Fixation of Acute Tibiofibular Syndesmotic Injury
NCT02930486 ·Status: COMPLETED ·Phase: NA