Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement
NCT07689279 · Status: NOT_YET_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 604
Last updated 2026-07-08
Summary
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.
The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.
Objectives:
The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.
Study design:
The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.
Study population:
The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges
Conditions
- Aortic Stenosis, Severe
Interventions
- DEVICE
-
Transcatheter Heart Valve
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention.
Sponsors & Collaborators
-
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
lead OTHER
Principal Investigators
-
Ronak Delewi, Prof. Dr. · Amsterdam University Medical Center
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-08-01
- Primary Completion
- 2033-08-01
- Completion
- 2033-08-01
More Related Trials
-
Transfemoral TAVI With or Without Coronary Angiogram in Patients With Severe Aortic Stenosis (PURE TAVI)
NCT06898086 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI).
NCT01586910 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of Arrhythmias in Patients Undergoing Transcatheter Aortic Valve Implantation Using a Small Insertable Cardiac Monitoring Device
NCT02559011 ·Status: COMPLETED
-
The Safety and Effectiveness of Transcatheter Aortic Valve Raplacemet in Intermediate Risk Patients With Bicuspid Aortic Stenosis
NCT03163329 ·Status: UNKNOWN ·Phase: PHASE2
-
Safety & Efficacy Study of the Medtronic CoreValve® System-Treatment of Symptomatic Severe Aortic Stenosis With Significant Comorbidities in Extreme Risk Subjects Who Need Aortic Valve Replacement
NCT01675440 ·Status: COMPLETED
-
Randomized Trial of TAVI vs. SAVR in Patients With Severe Aortic Valve Stenosis at Low to Intermediate Risk of Mortality
NCT03112980 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Observational Study to Collect Data of Patient Which Recieving a TAVI in TAVI Procedure
NCT07215143 ·Status: NOT_YET_RECRUITING
-
Cerebrovascular EveNts in Patients Undergoing TranscathetER Aortic Valve Implantation With Balloon-expandable Valves Versus Self-expandable Valves.
NCT03588247 ·Status: COMPLETED
-
Comparison of a Single Versus Double Perclose Technique for TAVR
NCT06173115 ·Status: RECRUITING ·Phase: NA
-
The TransCatheter Valve and Vessels Trial
NCT03424941 ·Status: COMPLETED ·Phase: NA
-
TAV-in-SAV in Japanese Patients
NCT06826027 ·Status: ACTIVE_NOT_RECRUITING
-
Safety and Performance Study of the Optimum Transcatheter Aortic Valve
NCT04076150 ·Status: RECRUITING ·Phase: NA
-
Outcomes of Transcatheter Aortic Valve Implantation in Management of Severe Symptomatic Aortic Stenosis
NCT03633383 ·Status: UNKNOWN
-
Long-term Prognosis and Valve Durability of TAVR
NCT06379386 ·Status: RECRUITING
-
Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System
NCT03788590 ·Status: UNKNOWN ·Phase: NA
-
Impact of Predilatation Between Self-expanding Valves
NCT04157920 ·Status: COMPLETED ·Phase: NA
-
Transcatheter Aortic Valve Implantation Without Predilation
NCT01539746 ·Status: COMPLETED ·Phase: NA
-
Echo-Guided vs Fluoroscopy-Guided Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis(ECHO-TAVR)
NCT07317804 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
ADVANCE Direct Aortic Study
NCT01676727 ·Status: COMPLETED
-
Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement
NCT01240902 ·Status: COMPLETED ·Phase: NA
-
Assessment of St Jude Medical Portico Re-sheathable Transapical Aortic Valve System
NCT01742598 ·Status: WITHDRAWN ·Phase: NA
-
TRANscatheter or SurgIcal Aortic Valve ReplacemenT in All-Comers With Severe Aortic Valve Stenosis
NCT02838199 ·Status: WITHDRAWN ·Phase: PHASE4
-
TAVR for Aortic Valve Disease
NCT05439863 ·Status: RECRUITING
-
A Prospective, Multicenter, Single-arm Study to Evaluate a Transcatheter Aortic Valve System Safety and Efficacy for the Treatment of Patients With Severe Aortic Stenosis
NCT06136429 ·Status: RECRUITING ·Phase: NA
-
Mortality Post-TAVI and Correlation With Haemodynamic Parameters.
NCT03769545 ·Status: COMPLETED