Comparison of Intraoperative Neuromonitoring With Transcartilaginous Needle Electrodes Versus Endotracheal Tube Electrodes in Thyroid and Parathyroid Surgery
NCT07638579 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 300
Last updated 2026-06-10
Summary
Injury to the recurrent laryngeal nerve (RLN) is among the most important complications in thyroid and parathyroid surgery. Intraoperative neuromonitoring (IONM) of the RLN using electrodes placed on the endotracheal tube is now a standard procedure to facilitate nerve detection and visual identification, to maintain its anatomical and functional integrity and to reduce the rate of nerve injuries. The most common neuromonitoring technique involves the use of electrodes located on the surface of the endotracheal tube, which are in contact with the vocal cords and record the electromyographic signals caused by the electrical stimulation of the RLN by a probe manipulated by the surgeon.
However, this technique has certain disadvantages:
(i) Correct placement of the endotracheal tube is technically demanding and requires an experienced anesthesiologist.
(ii) Improper placement of the tube by the anesthesiologist, its displacement during patient hyperextended neck positioning, intraoperative rotation, or saliva interference between the tube electrodes and the vocal cords may all lead to inability to receive adequate signals and limit the sensitivity of the method.
(iii) Intraoperative readjustment of the tube position can be time-consuming and difficult.
The above neuromonitoring method is associated with a high negative predictive value (92-100%) according to the literature. However, its positive predictive value ranges between 10% and 90% which means that in the case of a decrease or loss of the initial neurostimulation signal, the true injury of the RLN is 10-90%.
Neuromonitoring with intraoperative placement of electrodes in the thyroid cartilage is an alternative method, in which the electrodes are placed by the surgeon in the perichondrium of the thyroid cartilage at the beginning of the operation. Their placement is simple, with almost no learning curve and does not require further preparation of the surrounding structures. Similarly to the endotracheal tube electrode, these also record the electromyografic signal from the electrical stimulation of the laryngeal muscles and RLN, however they are more sensitive in detecting the movement of the vocal cords and can potentially record a higher and more stable neurostimulation signal. In this way, the rate of false positive signal loss could be reduced compared to the technique of neuromonitoring with the electrodes on the endotracheal tube.
This PhD thesis aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective multicenter study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. To achieve the above, at least 300 patients who will undergo thyroid or parathyroid gland surgery will be evaluated and intraoperatively will undergo neuromonitoring with both methods. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN.
Conditions
- Thyroid Surgeries
- Parathyroidectomy
Interventions
- DEVICE
-
intraoperative neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgery
This study aims to evaluate the effectiveness and reliability of neuromonitoring with transcartilaginous needle electrodes versus endotracheal tube electrodes in thyroid and parathyroid surgeries. It is a prospective study of diagnostic accuracy, with paired design, of the neuromonitoring signals (amplitude - latency), which will be obtained based on the standard algorithm V1, R1, EBSLN1, EBSLN2, R2, V2, before and after the end of the manipulations in each thyroid lobe, using both aforementioned techniques. Their positive and negative predictive value will be compared and evaluated with regard to the injury of the recurrent laryngeal nerve. After the surgery, on the 1st postoperative day, all patients will undergo laryngoscopy to exclude or confirm injury of the RLN. It is the first study that evaluates simultaneously both intraoperative neuromonitoring methods in the same patient and at such large group of patients.
Sponsors & Collaborators
-
Aristotle University Of Thessaloniki
lead OTHER
Principal Investigators
-
Stefanos Atmatzidis, Assistant Professor of Surgery · 2nd Surgical Department of Aristotle University of Thessaloniki
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-02-01
- Primary Completion
- 2027-12-31
- Completion
- 2028-06-01
Countries
- Greece
Study Locations
More Related Trials
-
Trial on Intraoperative Neuromonitoring (IONM) in Thyroid Cancer Surgery.
NCT04842994 ·Status: UNKNOWN ·Phase: NA
-
Parathyroid Reimplantation in Forearm Subcutaneous Tissue During Thyroidectomy: a Simple Way to Avoid Ipoparathyroidism and Evaluate Graft Function
NCT02194920 ·Status: COMPLETED
-
Effect of Reversed Tracking Method for Identification of EBSLN in Thyroid Surgery
NCT03680222 ·Status: UNKNOWN ·Phase: NA
-
Irreversible Electroporation for Recurrent or Metastatic Cervical Lymph Node Metastases From Thyroid Cancer: A Prospective Multicenter Single-Arm Study
NCT07328243 ·Status: RECRUITING ·Phase: NA
-
Thyroid Surgery With the New Harmonic Scalpel: a Prospective Randomized Study
NCT00784407 ·Status: COMPLETED ·Phase: NA
-
Study of Transaxillary Robotic Thyroidectomy Versus Standard Open Thyroidectomy: Prospective, Comparative Single-Center Study
NCT06693258 ·Status: RECRUITING ·Phase: NA
-
A Novel Technique for Endoscopic Transaxillary Thyroidectomy Comparison
NCT05735054 ·Status: UNKNOWN
-
Comparison of the Vocal Cord Imaging Techniques After Thyroidectomy
NCT02410928 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Technique for Assessment of Vocal Cord Movement by C-Mac Videolaryngoscope vs Airway Ultrasound.
NCT02847780 ·Status: COMPLETED ·Phase: NA
-
Clinical Trial on Harmonic Focus Shears Versus Ligasure Small Jaw and Clamp-and-tie Technique for Total Thyroidectomy
NCT01649154 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Study of Ultrasonic Coagulation Device and Bipolar Energy Sealing System
NCT01565486 ·Status: UNKNOWN ·Phase: NA
-
Thyroid Autotransplantation in Quadriceps Femoris Muscle
NCT04684953 ·Status: UNKNOWN ·Phase: NA
-
Visualization Versus Neuromonitoring of the External Branch of the Superior Laryngeal Nerve During Thyroidectomy.
NCT01395134 ·Status: COMPLETED ·Phase: NA
-
Thyroid Surgery With the New Harmonic Scalpel or the Electrothermal Bipolar Vessel Sealer
NCT00892164 ·Status: COMPLETED ·Phase: NA
-
Video-assisted Thyroid Surgery and Hypnosis in Thyroid Surgery
NCT01752283 ·Status: COMPLETED ·Phase: NA
-
Radiofrequency Ablation Versus Hemithyroidectomy of Small Thyroid Cancers
NCT06796348 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison Between Two Techniques During Thyroidectomy (Conventional Dissection Technique and Injection of Methylene Blue Dye Into Inferior Thyroid Artery Technique) Regarding Recurrent Laryngeal Nerve Identification and Preservation
NCT07067814 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Intra-operative Rapid Identification of Lymph Node and Parathyroid
NCT03268785 ·Status: UNKNOWN ·Phase: NA
-
Total Thyroidectomy With Harmonic Scalpel®
NCT00385983 ·Status: UNKNOWN ·Phase: PHASE4
-
Predictive Parameters for Difficult Tracheal Intubation Identification in Thyroid Surgery
NCT03578601 ·Status: COMPLETED
-
Effect of Polyglycolic Acid Mesh (Neoveil) in Thyroid Cancer Surgery
NCT03510143 ·Status: UNKNOWN ·Phase: NA
-
Methylene Blue Spray for Identification of Recurrent Laryngeal Nerve and Parathyroid Gland
NCT05113628 ·Status: COMPLETED ·Phase: NA
-
Comparison of Quality of Life Between Patients Underwent Transoral Endoscopic Thyroid Surgery and Conventional Surgery
NCT03048539 ·Status: UNKNOWN
-
Does Parathyroid Autofluorescence Reduces Unintensional Parathyroidectomy During Total Thyroidectomy with Central Lymph Node Compartment Dissection
NCT04339478 ·Status: COMPLETED
-
Medico-economic Evaluation Comparing the Use of Ultrasonic Scissors to the Conventional Techniques of Haemostasis in Thyroid Surgery by Cervicotomy
NCT01551914 ·Status: UNKNOWN ·Phase: PHASE3