VACStent Use for the Treatment of Anastomotic Leakage Following coloREctal Surgery

NCT07631702 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40

Last updated 2026-06-08

No results posted yet for this study

Summary

Introduction: Anastomotic leakage (AL) is the most severe complication following colorectal surgery and is associated with significant morbidity and mortality. VacStent therapy is a promising therapeutic approach, combining endoscopic vacuum therapy with mechanical stability of a stent and thereby allowing continued fecal passage. It may enhance anastomotic healing and reduce the need for a diverting ostomy or additional surgical procedures. VACStent Use for the treatment of anastomotic leakage following coloREctal surgery (VACURE) study aims to assess the efficacy and safety of VacStent therapy for colorectal AL.

Methods and analysis: VACURE is a prospective, multicenter efficacy study conducted at ten Dutch hospitals. Forty patients will be included over 18 months. All patients (≥18 years) with AL of the distal sigmoid, upper or mid rectum following colorectal resection will be considered for treatment with the VacStent GI Colon device. Trained endoscopists will perform stent placement, exchanges, and removal. Patients will remain hospitalized and those without diverting ostomy will receive osmotic laxatives and a fiber-free diet during treatment. Anastomotic healing will be confirmed endoscopically and radiologically posttreatment. The primary endpoint is the primary endpoint is the rate of participants that achieve complete anastomotic healing without the need for further interventions (confirmed by radiologic and endoscopic assessment). Secondary endpoints include safety, percentage of functioning anastomoses at 1 year post-treatment, 1-year stoma-free survival, diverting ostomy omission, healing time, number of stents, complications, reinterventions, length of hospitalization, pain scores, functional and quality of life outcomes up to 1 year posttreatment, patient experiences, and cost-effectiveness.

Conditions

  • Colorectal Surgery
  • Anastomotic Leak Rectum
  • Endoscopy, Digestive System
  • Vacuum Therapy
  • Stents
  • Anastomotic Leakage
  • Minimal Invasive

Interventions

DEVICE

VacStent GI Colon device

The VacStent GI Colon device (VacStent GI, VACStent GmbH, Fulda, Germany) is designed to treat colorectal AL and allows continued fecal passage through the stent. By combining the advantages of endoscopic vacuum therapy (EVT) with the mechanical stability of a stent, it promotes wound healing while maintaining luminal patency.

Sponsors & Collaborators

  • Amsterdam UMC, location VUmc

    lead OTHER

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-07-01
Primary Completion
2027-10-01
Completion
2028-10-01

Countries

  • Netherlands

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.