Quality and Safety of Real-Time Brachytherapy Treatments: Clinical Implementation of a Multipoint Scintillation Detector for Treatment Monitoring
NCT07580651 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-05-12
Summary
This project addresses a key safety gap in High-Dose-Rate (HDR) brachytherapy, where very high, localized radiation doses mean that small geometric deviations in catheter placement or radioactive source positioning can cause clinically significant errors. Incident reports from the Radiation Oncology Incident Learning System (RO-ILS) of the American Society for Radiation Oncology (ASTRO) and guidelines from the American Association of Physicists in Medicine Task Group 59 (AAPM TG-59) identify these events-often occurring between imaging and treatment delivery-as among the most critical. Unlike external beam radiotherapy, brachytherapy lacks a prior phantom-based verification step, making in vivo dosimetry the only real-time method to confirm delivered dose and detect anomalies in dwell time or source position. International bodies such as the International Atomic Energy Agency (IAEA) recommend this approach for quality management and accident prevention.
Multipoint plastic scintillation detectors (mPSD) offer water-equivalent, real-time measurements and can enable three-dimensional (3D) radioactive source tracking, but their clinical use remains limited due to integration challenges and the absence of well-defined alert thresholds.
The project aims to implement a real-time in vivo monitoring solution using an mPSD at the Centre régional intégré de cancérologie (CRIC) of Lévis, Québec (QC) for HDR gynecological and prostate brachytherapy. Objectives include: (1) demonstrating clinical feasibility and integration within existing clinical workflows; (2) validating the accuracy and precision of dose, dwell-time, and source-position measurements under clinical conditions; and (3) developing practical alert thresholds to identify common deviations. The central hypothesis is that mPSD technology can provide reliable, reproducible real-time measurements without lengthening procedures or disrupting clinical workflow.
The methodology relies on adapting the HYPERSCINT® platform for HDR in vivo use. A custom mPSD, consisting of several scintillators along a single optical fiber, will be insertable into a 6-French (6F) catheter.
Phase 1 focuses on feasibility and integration, including HDR-specific calibration, definition of detector insertion scenarios, integration of acquisition hardware, and staff training.
Phase 2 validates performance in at least 20 patients. Planned treatment parameters and time-stamped detector signals acquired at 1-10 hertz (Hz) will be used to reconstruct delivered dose, dwell times, and source-to-detector distances. Measurement accuracy and reproducibility will be quantified using mixed-effects statistical models.
Phase 3 establishes preliminary alert thresholds based on deviations in dose, time, and position, along with visualization tools such as Bland-Altman plots, although these thresholds will not be applied clinically during the study.
Expected outcomes include demonstrated feasibility of in vivo mPSD monitoring, quantitative performance metrics with confidence intervals, identification of influential factors and operational recommendations, preliminary alert thresholds with reporting templates, and a roadmap for sustainable deployment in Lévis and other centers. Scientific outputs will also be produced for dissemination across the Santé Québec network.
Conditions
- Prostate Cancer
- Gynecologic Cancers
Interventions
- DEVICE
-
Brachytherapy treatment monitoring using a plastic scintillation detector
Typical brachytherapy treatments are conducted without dose or source position monitoring in real-time. This intervention will assess the feasibility of using a scintillation detector to that end.
Sponsors & Collaborators
-
CISSS de Chaudière-Appalaches
lead OTHER_GOV
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2027-01-15
- Primary Completion
- 2027-12-31
- Completion
- 2028-05-01
More Related Trials
-
CyberKnife Radiosurgery For Low & Intermediate Risk Prostate Cancer: Emulating HDR Brachytherapy Dosimetry
NCT00643617 ·Status: COMPLETED ·Phase: NA
-
LDR vs. HDR Brachytherapy for Prostate Cancer
NCT03426748 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Hemiablative Focal Brachytherapy Pilot Study
NCT02643511 ·Status: UNKNOWN ·Phase: PHASE2
-
Radiation Therapy in Combination With Brachytherapy for Clinically Localized, Intermediate Risk Prostate Cancer
NCT02280356 ·Status: COMPLETED ·Phase: PHASE2
-
Prospective Evaluation of Focal Brachytherapy Using Cesium-131 For Patients With Low Risk Prostate Cancer
NCT02290366 ·Status: WITHDRAWN ·Phase: NA
-
Assessing the Potential for Reduced Toxicity Using Focal Brachytherapy in Early Stage, Low Volume Prostate Cancer
NCT01354951 ·Status: TERMINATED ·Phase: PHASE2
-
C-arm Cone-beam CT in Prostate Brachytherapy
NCT02322931 ·Status: UNKNOWN ·Phase: NA
-
Twice High Dose External Beam Radiotherapy by Image-guided Tomotherapy for Organ-confined Prostate Cancer Treatment Emulating High Dose Radiation (HDR) Brachytherapy
NCT03553212 ·Status: TERMINATED ·Phase: NA
-
CT-validation of Ultrasound Based Planning for High Dose Rate (HDR) Prostate Brachytherapy Using Vitesse
NCT01248741 ·Status: COMPLETED ·Phase: NA
-
HDR Brachytherapy vs. LDR Brachytherapy Monotherapy in Localized Prostate Cancer
NCT02628041 ·Status: COMPLETED ·Phase: PHASE2
-
Focal Radiation Therapy (HDR-Brachytherapy) for the Treatment of Prostate Cancer
NCT07468903 ·Status: RECRUITING ·Phase: NA
-
High-Dose-Rate Brachytherapy
NCT00913939 ·Status: RECRUITING ·Phase: NA
-
Comparison of HDR vs. LDR Brachytherapy as Monotherapy for Intermediate Risk Prostate Cancer
NCT02692105 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE3
-
Study Evaluating the Efficacy and the Tolerance of Pelvic-prostatic Hypo-fractionated Radiotherapy Followed by Boost in Patients With Prostate Adenocarcinoma Adverse Intermediate Risk or High Localized Risk
NCT03417336 ·Status: RECRUITING ·Phase: NA
-
HDR Focal: Feasibility Study
NCT02918253 ·Status: RECRUITING ·Phase: NA
-
Focal Brachytherapy in Patients With Selected "Low-risk" Prostate Cancer - a Phase-II-trial
NCT02391051 ·Status: RECRUITING ·Phase: PHASE2
-
Intensity-modulated Radiation Therapy From 70Gy to 80Gy in Localized Prostate Cancer
NCT02974231 ·Status: COMPLETED
-
Percutaneous High-dose Radiotherapy in Patients With Oligometastases of Prostate Carcinoma
NCT02264379 ·Status: COMPLETED
-
Evaluation of the Dose Received by the Prostate With in Vivo Dosimetry in Patients Treated With Daily IGRT Associated With IMRT Using Two Repositioning Techniques for Localized Prostate Cancer
NCT02279693 ·Status: TERMINATED ·Phase: NA
-
Hypofractionated Radiotherapy With a Focal Microboost for High-Risk and Locally Advanced Prostate Cancer
NCT07325721 ·Status: RECRUITING ·Phase: PHASE2
-
Focal HDR Brachytherapy Boost to Stereotactic Radiotherapy
NCT04100174 ·Status: RECRUITING ·Phase: PHASE2
-
Combined LDR Boost and HDR Whole Gland
NCT03323879 ·Status: TERMINATED ·Phase: PHASE1/PHASE2
-
Multi-omic Approach to Study HDR Brachytherapy for Favorable Risk and Low Tier Intermediate Risk Prostate Cancer
NCT06200974 ·Status: RECRUITING
-
A Study of Focal Salvage High-Dose-Rate Brachytherapy for Prostate Gland Only Recurrence
NCT04645810 ·Status: WITHDRAWN ·Phase: NA
-
Internal Radiation Therapy With or Without External-Beam Radiation Therapy in Treating Patients With Localized Prostate Cancer
NCT00714753 ·Status: COMPLETED ·Phase: PHASE2