Magnesium-Titanium Hybrid Intramedullary Nail System For Long Bone Fractures
NCT07569575 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 160
Last updated 2026-05-06
Summary
This is a prospective, multicenter, randomized, controlled, non-inferiority clinical trial designed to evaluate the safety and effectiveness of the magnesium-titanium hybrid intramedullary nail system compared with the marketed metal locked intramedullary nail in the treatment of long bone fractures of the extremities.
Conditions
- Tibial Fracture
- Femoral Fracture
- Humeral Fracture
Interventions
- DEVICE
-
Magnesium-Titanium Hybrid Intramedullary Nail System
The magnesium-titanium hybrid intramedullary nail system is inserted into the medullary canal through the proximal or distal end of the bone via standard intramedullary fixation surgical procedures, achieving fixation of the fracture site through intramedullary stabilization. This device provides load-sharing fixation for the fracture. The titanium alloy main body of the product delivers continuous, reliable mechanical support to ensure the overall stability of fracture fixation. The biodegradable magnesium components gradually degrade in vivo, releasing magnesium ions that participate in regulating the local bone repair microenvironment, thereby synergistically supporting the fracture healing process.
- DEVICE
-
Commercially Locked Metallic Intramedullary Nail
This is a commercially available locked metallic intramedullary nail manufactured by Double Medical Technology Inc., with the National Medical Products Administration (NMPA) registration certificate number: NMPA 20153131195. It is selected as the control device based on the following: 1) Double Medical is a leading orthopedic enterprise in China, and its products are widely used clinically with proven efficacy and safety; 2) The indications of the control device fully cover those of the investigational device.
Sponsors & Collaborators
-
HuaMg Perfection Med Tech (Suzhou) Co., Ltd.
lead INDUSTRY
Principal Investigators
-
Ling Qin, PhD · Chinese University of Hong Kong
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-05-01
- Primary Completion
- 2027-03-29
- Completion
- 2027-12-31
Countries
- China
Study Locations
More Related Trials
-
A Multicenter Randomized Trial Comparing IM Nails and Plate Fixation in Proximal Tibial Fractures
NCT00429585 ·Status: COMPLETED ·Phase: NA
-
Clinical Follow-up to Evaluate the Clinical Usefulness of Gentamicin-coated Titanium Nails in Tibia Fractures
NCT01282294 ·Status: COMPLETED
-
PMCF Study on the Safety, Performance and Clinical Benefits Data of the XtraFix® Small External Fixation System
NCT05943574 ·Status: COMPLETED
-
Comparison of Healing Measures Tibial Fractures Following Standard Intramedullary Nailing or Micromotion Tibial Intramedullary Nailing
NCT06679049 ·Status: RECRUITING ·Phase: NA
-
Treatment of Intertrochanteric Fracture With New Type of Intramedullary Nail
NCT01437176 ·Status: UNKNOWN ·Phase: NA
-
The CHINA TFNA Study
NCT03635320 ·Status: COMPLETED ·Phase: NA
-
Long vs Extended-short Nail When Treating Proximal Femur Fractures
NCT04652310 ·Status: RECRUITING ·Phase: NA
-
A Prospective Randomised Multicenter Study Comparing the Sliding Hip Screw and the Intertan Nail in Trochanteric and Subtrochanteric Femoral Fractures
NCT00621088 ·Status: COMPLETED ·Phase: NA
-
Open Tibia Fractures a Comparative Study Between Biplane External Fixator and Locked Intramedullary Nail
NCT02064595 ·Status: COMPLETED ·Phase: NA
-
Retrieval Study and Histological Examination Of A Hip Femoral Components With Hydroxyapatite Coatings
NCT00757653 ·Status: TERMINATED ·Phase: NA
-
A Post-Market Clinical Evaluation of the Treatment of Tibia Fractures With the T2 Alpha Tibia Nailing System
NCT04015167 ·Status: COMPLETED
-
Incidence of Cut-out Using Intramedullary Nails With Double Cephalic Screw vs. Unique in Pertrochanteric Fractures
NCT06293495 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Orthopedic Intelligent Navigation System in the Treatment of Fresh Femoral Neck Fractures
NCT06713018 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Efficacy Study of Surgical Technique in Intramedullary Tibia Nailing, Using Trigen META Tibia Nails
NCT01358292 ·Status: COMPLETED ·Phase: PHASE4
-
Post Market Evaluation of Clinical Safety and Performance of the Fitbone Transport and Lengthening System
NCT06400732 ·Status: TERMINATED
-
Autologous Bone Marrow Concentration for Femoral Shaft Fracture Union
NCT03794622 ·Status: UNKNOWN
-
Assessment of Fixation Strategies for Severe Open Tibia Fractures
NCT01494519 ·Status: COMPLETED ·Phase: PHASE3
-
Safety and Effectiveness of Proximal Femoral Nail Antirotation for the Treatment of Intertrochanteric Femoral Fracture
NCT02880501 ·Status: UNKNOWN ·Phase: NA
-
Cemented K-wire Fixation vs Open Transfixion Pinning
NCT03082872 ·Status: COMPLETED ·Phase: NA
-
Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head
NCT02877472 ·Status: UNKNOWN ·Phase: NA
-
Evaluate Clinical and Radiological Outcomes After Limb Reconstruction Using Monorail Fixator Over Intramedullary Nailing in Tibial Open Fractures With Bone Loss
NCT05296785 ·Status: UNKNOWN ·Phase: NA
-
Static Helical Screw Locking of Pertrochanteric Femur Fractures Using the TFN-A
NCT04851509 ·Status: RECRUITING ·Phase: NA
-
Zimmer® Natural Nail® (ZNN) Bactiguard Tibia Post-Market Clinical Follow-up Study
NCT05022485 ·Status: RECRUITING
-
A Clinical Trial of a Metal on Poly Component Versus CORAIL Stem: A Bone Mineral Density Study
NCT01558752 ·Status: COMPLETED ·Phase: NA
-
Carbon Fiber Implants
NCT03382041 ·Status: TERMINATED ·Phase: NA