A Phase II Trial of Fetal Embolization for Vein of Galen Malformation
NCT07483255 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2026-07-23
Summary
This is a prospective, single-arm non-randomized interventional study of fetuses to assess the efficacy and safety of fetal embolization of VOGM. Subjects will receive a one-time study intervention of fetal embolization, at or after 34 weeks of gestation. After delivery, neurological assessments will be performed every 6 months for 2 years (adjusted for gestational age). Data will be compared to historical cohorts.
Conditions
- Vein of Galen Malformations
Interventions
- DEVICE
-
Fetal embolization of vein of Galen malformation using Target XL and XXL Detachable Coils
The study involves a single fetal intervention of maternal transuterine, fetal transcranial torcular puncture and median prosencephalic vein embolization. Detachable platinum coils (Target XL and XXL Detachable Coil, Stryker Neurovascular) will be used to pack the prosencephalic varix.
Sponsors & Collaborators
-
Darren Orbach
lead OTHER
Principal Investigators
-
Darren Orbach, MD PhD · Boston Children's Hospital, Boston, MA 02115
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-20
- Primary Completion
- 2030-12-31
- Completion
- 2032-12-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Follow Up on Freestyle Valves in Children
NCT00385112 ·Status: COMPLETED
-
Long-term Safety Study of the GORE® HELEX® Septal Occluder
NCT00581308 ·Status: COMPLETED ·Phase: NA
-
Closure of Perimembranous Ventricular Septal Defects With The AMPLATZER® Membranous VSD OCCLUDER
NCT00578708 ·Status: COMPLETED ·Phase: PHASE1
-
A Clinical Evaluation of the Safety and Effectiveness of the MitraClip System in the Treatment of Clinically Significant Functional Mitral Regurgitation
NCT02444338 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the GORE PV1 Device in Patients With Pulmonary Valve Dysfunction
NCT03441971 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
An International Multicenter Study on Transcatheter Device Closure of Perimembranous Ventricular Septal Defects
NCT06823635 ·Status: RECRUITING
-
Standardized Goal-Directed vs. Self-Directed Valsalva Maneuver for the Assessment of Patent Foramen Ovale
NCT06670781 ·Status: RECRUITING ·Phase: NA
-
A Pilot Study Investigating the Clinical Use of Tissue Engineered Vascular Grafts in Congenital Heart Surgery
NCT01034007 ·Status: COMPLETED ·Phase: PHASE1
-
PC-Trial: Patent Foramen Ovale and Cryptogenic Embolism
NCT00166257 ·Status: UNKNOWN ·Phase: PHASE4
-
Safety and Effectiveness of the Nit-Occlud® Lê VSD Spiral Coil System
NCT00390702 ·Status: COMPLETED ·Phase: NA
-
Microvascular Plug (MVP) for the Treatment of Pulmonary ArterioVenous Malformations (PAVMs)
NCT04396041 ·Status: COMPLETED
-
Study of Safety and Efficacy of the Percutaneous Reduction of Mitral Valve Regurgitation in Heart Failure Patients
NCT00787293 ·Status: SUSPENDED ·Phase: PHASE2
-
Xeltis Bioabsorbable Pulmonary Valved Conduit Pivotal Study
NCT03022708 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Feasibility Study of the Millipede Transcatheter Annuloplasty Ring System in Patients With Functional Mitral Regurgitation
NCT04147884 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Multicenter Trial of ECMO in Children With Severe Cardiac Failure Using the Cardiohelp System
NCT06080074 ·Status: RECRUITING ·Phase: PHASE2
-
Safety and Effectiveness Study of the Solysafe Septal Occluder in Patients With Atrial Septum Defect and Patent Foramen Ovale
NCT00207376 ·Status: COMPLETED ·Phase: NA
-
PV Loop & Coarctation Study
NCT05362721 ·Status: ACTIVE_NOT_RECRUITING
-
Xeltis Pulmonary Valved Conduit Safety and Performance Study
NCT03405636 ·Status: WITHDRAWN ·Phase: NA
-
AMBULATE VASCADE MVP Same Day Discharge Retrospective Registry
NCT04538781 ·Status: COMPLETED
-
Safety and Effectiveness Study of Dragonfly System for Functional Mitral Regurgitation
NCT04733404 ·Status: RECRUITING ·Phase: NA
-
Endoscopic Closure of Tracheoesophageal Fistulas With Occluder Device
NCT01153061 ·Status: TERMINATED ·Phase: PHASE4
-
Safety and Effectiveness Study of Dragonfly System for Degenerative Mitral Regurgitation
NCT04734756 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Mitral Annular Repair With the CathHELIX™ Transcatheter System in Subjects With FMR
NCT07188233 ·Status: RECRUITING ·Phase: NA
-
Emergency/Compassionate Use - Membranous VSD Occluder
NCT00583505 ·Status: NO_LONGER_AVAILABLE
-
The Effect of Device Closure of Patent Foramen Ovale in Elderly Patients With Crytogenic Stoke/TCI
NCT01018355 ·Status: TERMINATED ·Phase: NA