Trial Outcomes & Findings for AutoFocus360 Sound Quality Preference and Claims Study (NCT NCT07224919)

NCT ID: NCT07224919

Last Updated: 2026-08-10

Results Overview

Participants will complete an A-B paired-comparison listening task to assess subjective preference for noise disturbance between two hearing aid conditions. In other words, participants will be asked "which sample has less disturbing noise". During testing, participants will listen to short audio recordings that vary in talker location and noise type. For each trial, participants will indicate which of the two recordings (A or B) has less bothersome background noise. The outcome measure will be the the percentage of "A preferred" versus "B preferred" responses aggregated across all trials and participants for a given noise and talker location. In other words, for a single noise x talker location combination, the outcome measures for AF360 and FWD should add up to 100. Binary preference data will be analyzed using inferential statistics.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

30 participants

Primary outcome timeframe

During a single 2-hour onsite study session

Results posted on

2026-08-10

Participant Flow

Participant milestones

Participant milestones
Measure
Participant Group
Participants will listen to scenes of a talker speaking in two types of noise from either the front, left, rear, and right using AutoFocus360 and fixed directional microphones. Condition order is randomized between participants and masked from participants and experimenters.
Overall Study
STARTED
30
Overall Study
COMPLETED
20
Overall Study
NOT COMPLETED
10

Reasons for withdrawal

Reasons for withdrawal
Measure
Participant Group
Participants will listen to scenes of a talker speaking in two types of noise from either the front, left, rear, and right using AutoFocus360 and fixed directional microphones. Condition order is randomized between participants and masked from participants and experimenters.
Overall Study
Completed earlier version of protocol
10

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Participant Group
n=20 Participants
Participants will listen to scenes of a talker speaking in two types of noise from either the front, left, rear, and right using AutoFocus360 and fixed directional microphones. Condition order is randomized between participants and masked from participants and experimenters.
Age, Continuous
71.4 Years
STANDARD_DEVIATION 7.7 • n=20 Participants
Sex: Female, Male
Female
12 Participants
n=20 Participants
Sex: Female, Male
Male
8 Participants
n=20 Participants

PRIMARY outcome

Timeframe: During a single 2-hour onsite study session

Participants will complete an A-B paired-comparison listening task to assess subjective preference for noise disturbance between two hearing aid conditions. In other words, participants will be asked "which sample has less disturbing noise". During testing, participants will listen to short audio recordings that vary in talker location and noise type. For each trial, participants will indicate which of the two recordings (A or B) has less bothersome background noise. The outcome measure will be the the percentage of "A preferred" versus "B preferred" responses aggregated across all trials and participants for a given noise and talker location. In other words, for a single noise x talker location combination, the outcome measures for AF360 and FWD should add up to 100. Binary preference data will be analyzed using inferential statistics.

Outcome measures

Outcome measures
Measure
Participant Group
n=20 Participants
Participants will listen to scenes of a talker speaking in two types of noise from either the front, left, rear, and right using AutoFocus360 and fixed directional microphones. Condition order is randomized between participants and masked from participants and experimenters.
Noise Disturbance Sound Quality Attribute
Noise 1; Left target; AF360
81.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Left target; FWD
18.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Rear target; AF360
98 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Rear target; FWD
2 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Right target; AF360
80 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Right target; FWD
20 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Front target; AF360
74.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Front target; FWD
25.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Left target; AF360
68.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Left target; FWD
31.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Rear target; AF360
80.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Right target; AF360
70.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Right target; FWD
29.5 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Front target; AF360
96 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 1; Front target; FWD
4 Percentage of preferences
Noise Disturbance Sound Quality Attribute
Noise 2; Rear target; FWD
19.5 Percentage of preferences

SECONDARY outcome

Timeframe: During a single 2-hour onsite study session

Participants will complete an A-B paired-comparison listening task to assess subjective preference for speech clarity between two hearing aid conditions. In other words, participants will be asked "which sample has clearer speech". During testing, participants will listen to short audio recordings that vary in talker location and noise type. For each trial, participants will indicate which of the two recordings (A or B) has clearer speech. The outcome measure will be the proportion of "A preferred" versus "B preferred" responses aggregated across all trials and participants for a given noise and talker location. In other words, for a single noise x talker location combination, the outcome measures for AF360 and FWD should add up to 100. . Binary preference data will be analyzed using inferential statistics.

Outcome measures

Outcome measures
Measure
Participant Group
n=20 Participants
Participants will listen to scenes of a talker speaking in two types of noise from either the front, left, rear, and right using AutoFocus360 and fixed directional microphones. Condition order is randomized between participants and masked from participants and experimenters.
Speech Clarity Sound Quality Attribute
Noise 1; Front target; FWD
28.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Left target; AF360
41.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Left target; FWD
58.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Rear target; FWD
8.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Right target; AF360
34.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Right target; FWD
65.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Front target; AF360
79 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Front target; FWD
21 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Right target; AF360
51 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Right target; FWD
49 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Front target; AF360
71.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 1; Rear target; AF360
91.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Left target; AF360
42.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Left target; FWD
57.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Rear target; AF360
96.5 Percentage of preferences
Speech Clarity Sound Quality Attribute
Noise 2; Rear target; FWD
3.5 Percentage of preferences

Adverse Events

Participant Group

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Jonathan Vaisberg

Sonova

Phone: 905-745-6785

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place