Handheld Point of Care Electro-Diagnostic Device
NCT07223827 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2026-02-09
Summary
There are currently several products offering POC EEG, intended to be deployed on each patient individually and continuously. The investigators propose studying a different approach by using a migrating POC electrodiagnostic device that is deployed directly by the onsite provider and is actively used, like other POC devices, to acquire real-time diagnostic insight and facilitate immediate medical decision making. This can significantly shorten time to treatment which in several neurological and neurosurgical conditions, and thus, can significantly improve patient outcome.
The investigational POC investigational device is based on a handheld limited electrode array, complemented by various stimulation modalities such as SSEP, VEP and BAEP, and potentially other sensors. For this study, the investigators intend to use readily available industry standard stimulators and only use the proposed POC investigational device to acquire and analyze the data. The POC investigational electrodiagnostic prototype was assembled using OpenBCI8 electronic board and electrodes, based on ADS 129X chip by Texas Instruments, that was shown to provide an adequate low-cost solution for electrodiagnostic data acquisition.
Conditions
- Neurologic Findings
Interventions
- DIAGNOSTIC_TEST
-
POC EEG
The PI will apply the POC investigational device dry electrodes, as well as SOC SSEP stimulator to the participant and run a standardized diagnostic testing sequence, to cover all 4 limbs, spine, and head. The device connects to a laptop via Bluetooth, and the acquired electrodiagnostic data is visualized on the screen. The PI will analyze the acquired data and determine lateralization, localization, and presumed nature of the lesion or pathology causing the patient's symptoms. The direct contact with the participant should take10-20 minutes. The inferred lateralization, localization, and nature of the presumed lesion, will be then documented, to be compared to the diagnostic insight of using SOC diagnostic methods such as CT, MRI, EEG, SSEP, etc. The participant will receive their regular SOC management and a single, brief evaluation using the POC investigational device.
Sponsors & Collaborators
-
Indiana University
lead OTHER
Principal Investigators
-
Sergiu Abramovici, MD · Indiana University
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-01-10
- Primary Completion
- 2026-12-31
- Completion
- 2026-12-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Preliminary Testing of a Novel Device to Detect Epileptic Seizures
NCT02286271 ·Status: COMPLETED
-
Validation Of TBI Detection System For Head Injured Patients
NCT02367300 ·Status: COMPLETED
-
First Study With a Brain Implant to Help Locked-in Patients Communicate at Home
NCT02224469 ·Status: COMPLETED ·Phase: NA
-
EEG@HOME (Phase 3b of the Project, Interviews)
NCT02428348 ·Status: TERMINATED ·Phase: NA
-
Diagnostic Value of Prehospital EEG in Non-convulsive Status Epilepticus
NCT02344706 ·Status: UNKNOWN
-
EEG@HOME (Phase 1 of the Project)
NCT02408666 ·Status: COMPLETED ·Phase: NA
-
EEG@HOME (Phase 2 of the Project, Measurements in Healthy Volunteers)
NCT02408653 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Spinal, Cortical, and Sensorimotor Biomarkers in Motor Neurone Disease
NCT06320444 ·Status: RECRUITING
-
Putting Electroencephalography (EEG) in the Emergency Department
NCT01671475 ·Status: COMPLETED ·Phase: PHASE2
-
Evaluation of StatNet Device for Electroencephalogram (EEG) Recordings
NCT03103425 ·Status: COMPLETED
-
Feasibility of mindBEAGLE in Disorders of Consciousness or Locked-In Syndrome
NCT02772302 ·Status: COMPLETED ·Phase: NA
-
A Wireless EEG Patch for Continuous Electrographic Monitoring
NCT03583957 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Diagnosing Epilepsy To EffeCT Change
NCT07110337 ·Status: RECRUITING ·Phase: NA
-
Correlate of Surface Electroencephalogram (EEG) With Implanted EEG Recordings (ECOG)
NCT03629743 ·Status: ACTIVE_NOT_RECRUITING
-
Cortical Excitability Assessment Using Paired Pulses
NCT02245061 ·Status: UNKNOWN ·Phase: NA
-
Detecting Generalized Tonic-Clonic Seizures With a Seizure Detection and Warning System in Epilepsy Patients
NCT02371200 ·Status: COMPLETED
-
Cardiac Arrest Recovery EEG Study
NCT00483873 ·Status: UNKNOWN
-
Developing an EEG Probe for Studying and Modulating Cognitive Control
NCT05612659 ·Status: COMPLETED ·Phase: NA
-
Seizure Detection and Warning System in Epilepsy Patients
NCT02555410 ·Status: COMPLETED
-
Detecting PNES With Single-channel sEMG
NCT03313362 ·Status: UNKNOWN ·Phase: NA
-
EEG@HOME (Phase 4 of the Project)
NCT02394639 ·Status: WITHDRAWN ·Phase: NA
-
Development of a Point of Care System for Automated Coma Prognosis
NCT03826407 ·Status: UNKNOWN
-
Home Ultra-long Term EEG Monitoring for Rare Epilepsies and Developmental and Epileptic Encephalopathies
NCT06855901 ·Status: RECRUITING ·Phase: NA
-
Seizure Detection and Warning System for Epilepsy Patients
NCT01874600 ·Status: UNKNOWN
-
Characterization and Analysis of Evoked Cortical Responses in Participants With Medication-intractable Epilepsy
NCT07014592 ·Status: RECRUITING ·Phase: NA