Inter-rater Reliability of the GNRB Arthrometer
NCT07200700 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 17
Last updated 2025-10-01
Summary
Although clinical examination is commonly used to diagnose an anterior cruciate ligament (ACL) injury, the method is subjective. For many years, the arthrometer KT1000 has been used to verify clinical results, mostly due to its simplicity. While the KT1000 is no longer available for purchase, other arthrometers have been introduced, one being the Genoroub (GNRB). The latter has several automatic steps, has been marketed to have a higher reproducibility, and able to detect partial tears.
While the KT1000 and GNRB have previously been compared in several studies, it's mostly been compared in healthy subjects. The current study aim to analyse the results in a clinical environment on injured objects and compare the results both before and after ACL reconstruction. The main hypothesis was that the GNRB offers high inter-rater reliability between two examinors and can replace the KT1000 in the everyday clinical setting.
Methods Consecutively, 20 patients \> 18 years of age, 12 men and 8 women, with an ACL injury scheduled for surgical reconstruction, were included. All patients were screened between August 2020-2021 at the NU Hospital Group in Trollhattan, Sweden. To be eligible, the patients had to present with a first time ACL injury verified by clinical examination with or without an magnetic resonance imaging, a healthy contralateral knee and to not have sustained multi-ligament injuries to the knee. Minor collateral ligament injuries and meniscal and cartilage injuries were included.
All patients received both spoken and written information before signing an informed consent. The study was approved by the Swedish ethical committee.
All patients were examined both pre- and postoperatively, in accordance with local standard protocol, including range of motion, knee laxity measurements (manual Lachman test, pivot shift test) The participants were examined starting with the healthy/uninjured knee. Who of the two examinors started the testing was randomly decided, however alternated at the follow-up. Clinical examination and KT1000 testing were only performed by examiner 2, given the need for experience with the KT1000 for accurate results.
Statistically, a side-to-side difference (SSD) of 3 mm was set to indicate ACL injury according to general concensus. For the dichotomous values, an SSD of ≥3 mm was considered a yes to ACL injury and \<3mm a no, respectively, for both the GNRB and the KT1000.
A power analysis was performed estimating a difference of 1 mm between examiners with an SD of 1 mm, resulting in 17 patients needed to reach a power of 80% with a significance level of 0.05.
As for the inter-rater reliability, the intra-correlation coefficient (ICC) was calculated and considered poor (\<0.5), moderate (0.5-0.75), good (0.75-0.9) or excellent (\>0.9).
Conditions
- Anterior Cruciate Ligament Reconstruction
Interventions
- DIAGNOSTIC_TEST
-
Knee laxity arthrometer
Inter-reliability analysis of the GNRB arthrometer between two examinors compared to standard KT 1000 arthrometer
Sponsors & Collaborators
-
Vastra Gotaland Region
lead OTHER_GOV
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-08-24
- Primary Completion
- 2022-12-20
- Completion
- 2022-12-20
Countries
- Sweden
Study Locations
More Related Trials
-
I-beam and Cruciate Tibial Components Used in Total Knee Replacement
NCT00588783 ·Status: TERMINATED
-
Alignment Comparison Between TruMatch™ Personalized Solutions and Conventional Total Knee Replacement Instrumentation
NCT01108237 ·Status: COMPLETED ·Phase: NA
-
Prescribed Knee Brace Treatments for Osteoarthritis of the Knee (Knee OA)
NCT04651673 ·Status: ENROLLING_BY_INVITATION
-
Time-dependent Improvement of Functional Outcome Following LCS Rotating Platform TKR
NCT01030848 ·Status: UNKNOWN
-
Investigation of Specific Protein/Markers in Patients With Osteoarthritis of the Knee Having a Total Knee Replacement
NCT01611441 ·Status: COMPLETED
-
Nanoscope Cost Analysis Study
NCT06603740 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Mobility in Subjects With Severe Knee Osteoarthritis Who Are to Undergo Total Knee Replacement
NCT05488093 ·Status: RECRUITING ·Phase: NA
-
Prospective Clinical Study Evaluating Tibiofemoral Rotational Alignment Using Intraoperative Sensing During Total Knee Arthroplasty (TKA)
NCT02286739 ·Status: TERMINATED ·Phase: NA
-
ATTUNE Single-Use Instrumentation vs. ATTUNE Reusable Instrumentation in Primary Total Knee Arthroplasty
NCT02574312 ·Status: COMPLETED ·Phase: NA
-
Radiographic Migration Analysis of the ATTUNE Cementless CR Fixed-Bearing Total Knee Replacement
NCT06189872 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Clinical Trial of Precise Positioning and Intelligent Operation of Surgical Robots to Reconstruct Cruciate Ligaments
NCT04980183 ·Status: UNKNOWN ·Phase: NA
-
Total Knee Arthroplasty Guidance Systems Study
NCT02830997 ·Status: COMPLETED
-
Use of the LRU Pillow in the Acute Setting Following Total Knee Arthroplasty
NCT01814033 ·Status: UNKNOWN ·Phase: NA
-
Clinical Outcomes and Cost-effectiveness Analysis of ShapeMatch Technology
NCT01483066 ·Status: TERMINATED ·Phase: PHASE4
-
All Ligaments Left In Knee Arthroplasty Trial
NCT03302013 ·Status: UNKNOWN ·Phase: NA
-
Diagnostic Value of a Biomarker of Non-surgical Knee Osteoarthritis
NCT04324554 ·Status: UNKNOWN
-
Gait Analysis of a Lateral-Pivot Design Total Knee Replacement
NCT04275362 ·Status: RECRUITING
-
Robotic Assisted Surgery In Total Knee Replacement
NCT05842538 ·Status: RECRUITING ·Phase: NA
-
14022 ATTUNE Cementless RP Clinical Performance Evaluation
NCT02839850 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Reconstruction of the Anterior Cruciate Ligament(ACL-R) in the 30+-Year Old Assessed by Patient Reported Outcome Measures(PRO) Using the Nationwide Danish Knee Ligament Reconstruction Registry
NCT04592367 ·Status: COMPLETED
-
Diagnostic Value of Weight Bearing CT for Detecting Meniscal Tears
NCT04430829 ·Status: COMPLETED
-
A Trial of Mechanical Axis vs Kinematic Alignment in Total Knee Replacement
NCT02527148 ·Status: COMPLETED ·Phase: NA
-
Comparison of Alignment Achieved Using the VELYS Robotic-Assisted Solution Versus Manual Instrumentation in Total Knee Arthroplasty
NCT04730271 ·Status: COMPLETED ·Phase: NA
-
Triathlon® Cruciate Retaining (CR) Total Knee System Outcomes Study
NCT00957723 ·Status: COMPLETED ·Phase: NA
-
Mymobility Knee ROM
NCT06863428 ·Status: RECRUITING