Atrial Fibrillation: In Search for the Optimal Target for Rate Control
NCT07135258 · Status: NOT_YET_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 200
Last updated 2025-08-22
Summary
A rate control strategy is commonly adopted in the management of patients with Atrial Fibrillation (AF). Controversies remain as regards to what constitutes the optimal target of rate control.
Current clinical guidelines recommend a resting target heart rate of 80 to 100-110 beats per min (bpm). Such recommendations were based largely on findings of the RACE II Trial, the only study of its kind, which demonstrated noninferiority of the lenient versus a strict rate control approach. Despite merits of the study, interpretation of RACE II has been limited by its noninferiority design and the apparently stricter-than-predefined heart rate control in the "lenient" arm, rendering any genuine difference of superiority in either arm unknown. Application values of the RACE II study to patients with heart failure were also limited, because the constituent sample comprised mainly patients without heart failure at baseline.
Despite years of medical advances, therapeutic armamentarium available for AF patients decided for the rate control strategy had remained limited. Betablockers, nondihydropyridine calcium-channel blockers, and digoxin constitute the mainstay of armamentarium available for achieving rate control in AF. However, studies revealed that up to 30% of patients treated with betablockers, with or without digitalis glycoside, failed to achieve adequate rate control. On the other hand, a stricter rate control strategy is more frequently associated with side effects of medications, commonly bradycardia and hypotension. Furthermore, digoxin, with a narrow therapeutic range and precluded for use in significant renal impairment, was inconsistently associated with increased mortality.
Ivabradine is a specific funny current inhibitor, which blocks Hyperpolarization-activated Cyclic Nucleotide-gated cation channels (HCN) intra-cellularly and results in delayed diastolic depolarization in a use-dependent manner. Prior-believed to be exclusively expressed within the sinoatrial node, HCN was recently revealed to be also expressed in the atrioventricular node and throughout the myocardium. These invite a key clinical question as whether effects of ivabradine may extend beyond its conventional use.
Through promoting atrioventricular node refractoriness, ivabradine harbors a potential role in the ventricular rate control of symptomatic persistent AF. Ivabradine owing to its specific effect on heart rate reduction, without depressing cardiac contractility, should render it better tolerated than conventional agents with reduced risk of hypotension. Its use-dependent property may in theory also confer a low risk of bradycardia.
Indeed, experimental studies in animal models of persistent AF showed that ivabradine caused rate-dependent slowing of atrioventricular conduction and resultant ventricular rate reduction, without affecting atrial dominant frequency, arterial blood pressure or contractility. Research interest for its therapeutic repurposing is growing. Clinically, a role of ivabradine in ventricular rate control has been reported in cases and series. A small randomized, double-blinded, placebo-controlled trial showed that ivabradine reduced ventricular rate in patients with non-paroxysmal AF.
Therefore, this randomized, double-blinded, controlled, superiority, Phase III, investigator-initiated clinical trial aims to compare ivabradine and the convertional rate control agents with the expectation to generate important data on the novel role of ivabradine in achieving strict rate control in patients with non-paroxysmal AF. It will also provide unprecedented superiority trial data on any clinical benefits of a strict versus lenient rate control approach in AF management, with the use of ivabradine.
Conditions
- Atrial Fibrillation (Permanent)
- Atrial Fibrillation (AF)
Interventions
- DRUG
-
Ivabradine + Usual Care
For patients in the ivabradine arm targeting for strict rate control, ivabradine is started at 5mg BID, and titrated at follow-up visits if needed, up to 7.5mg BID to aim at the target heart rate \<80bpm. Uptitration of other existing or additional conventional rate control agents will considered after maximally tolerated dose of ivabradine. Conversely, if not tolerated, or if resting heart rate is persistently \<50bpm, ivabradine will be reduced to 2.5mg BID, followed by reassessment.
- DRUG
-
Placebo + usual care
For patients in the lenient rate control arm, medications will be adjusted, bidirectionally as appropriate, with a maximum heart rate that is tolerable by patient which is at \<110bpm. Routine heart rate control agents included betablockers, nondihydropyridine calcium channel blockers, or digoxin. All patients will be prescribed a matching placebo (morphologically identical to the comparison arm: ivabradine) that contains pharmacologically inactive cellulose.
Sponsors & Collaborators
-
The University of Hong Kong
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-10-01
- Primary Completion
- 2027-10-01
- Completion
- 2027-10-01
Countries
- Hong Kong
Study Locations
More Related Trials
-
Assessment of Intravenous Rate Control Response in Atrial Fibrillation Trial (AIRCRAFT)
NCT04234477 ·Status: WITHDRAWN ·Phase: PHASE4
-
Optimising Pacing Therapy, Integrated Medical Therapy, and Catheter AbLation for Atrial Fibrillation in Heart Failure Trial
NCT07238452 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
Cardiovascular Performance and Exercise Response in Patients With Persistent or Permanent Atrial Fibrillation and Heart Failure Pre and Post Cardioversion or Pace and Ablate
NCT07205679 ·Status: NOT_YET_RECRUITING
-
Routine Versus Aggressive Upstream Rhythm Control for Prevention of Early Atrial Fibrillation in Heart Failure
NCT00877643 ·Status: COMPLETED ·Phase: NA
-
Rate Control in Patients With Atrial Fibrillation
NCT04513509 ·Status: COMPLETED ·Phase: NA
-
Withdrawal of Treatment for Heart Failure Patients With Recovery From Tachycardia-induced Cardiomyopathy
NCT06128980 ·Status: RECRUITING ·Phase: PHASE2/PHASE3
-
Atrioventricular Node Ablation and Conduction System Pacing in Patients With Well Controlled Permanent Atrial Fibrillation (AF), Heart Failure and Preserved Ejection Fraction: Heart Rate Regularization Versus Medical Rate Control
NCT06833138 ·Status: RECRUITING ·Phase: NA
-
Atrial Fibrillation Management in Congestive Heart Failure With Ablation
NCT00652522 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronisation Therapy and AV Nodal Ablation Trial in Atrial Fibrillation Patients (CAAN-AF)
NCT01522898 ·Status: COMPLETED ·Phase: NA
-
Study to Determine the Response and Effectiveness of RSD1235 in Subjects With Atrial Fibrillation or Atrial Flutter
NCT00115791 ·Status: COMPLETED ·Phase: PHASE3
-
APAF: Assessment of Cardiac Resynchronization Therapy in Patients With Permanent Atrial Fibrillation
NCT00111527 ·Status: COMPLETED ·Phase: PHASE3
-
Treating Atrial Fibrillation in Heart Failure With Preserved Ejection Fraction: Ablation or Medication
NCT07272902 ·Status: RECRUITING ·Phase: NA
-
Catheter Ablation in Atrial Fibrillation Patients With HFpEF (STABLE-SR IV Trial)
NCT06125925 ·Status: RECRUITING ·Phase: NA
-
Atrial Fibrillation: Chronic Beta-blocker Use Versus As-needed Rate Control Guided by Implantable Cardiac Monitor
NCT05745337 ·Status: RECRUITING ·Phase: PHASE1
-
RAFT - Pace &Ablate
NCT06299514 ·Status: RECRUITING ·Phase: NA
-
Rate Control Versus Rhythm Control For Postoperative Atrial Fibrillation
NCT02132767 ·Status: COMPLETED ·Phase: PHASE3
-
Response to RSD1235 Compared to Placebo in Subjects With Atrial Arrhythmia After Heart Surgery
NCT00125320 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical Randomised Phase 2 Trial of AP31969 Versus Placebo for Rhythm Control of Atrial Fibrillation
NCT07267949 ·Status: RECRUITING ·Phase: PHASE2
-
Individualized Studies of Triggers of Paroxysmal Atrial Fibrillation
NCT03323099 ·Status: COMPLETED ·Phase: NA
-
Resync-AF (Rate vs Rhythm Control in AF Patients With CRT-D)
NCT01233648 ·Status: COMPLETED ·Phase: PHASE4
-
Atrial Fibrillation Ablation Compared to Rate Control Strategy in Patients With Impaired Left Ventricular Function
NCT02509754 ·Status: UNKNOWN ·Phase: PHASE4
-
Efficacy and Safety Evaluation of Azimilide or Sotalol vs Placebo for Treatment of Patients With Atrial Fibrillation.
NCT00035451 ·Status: COMPLETED ·Phase: PHASE3
-
Left Atrial Volume Changes Who Underwent Cardioversion and Recurrence of AF After RF Ablation in Persistent AF (SAFE-AF)
NCT06523738 ·Status: RECRUITING
-
Triggers and Risk Factors for Recurrence of Atrial Arrhythmias With the Use of Long-term Monitoring
NCT05526170 ·Status: ACTIVE_NOT_RECRUITING
-
Cardiovascular Risk Reduction in Atrial Fibrillation Trial
NCT04347330 ·Status: RECRUITING ·Phase: NA