Thopaz for PALs Evaluation

NCT07105436 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 20

Last updated 2026-03-17

No results posted yet for this study

Summary

Persistent air leaks (PALs) are a common postoperative complication resulting from tears in the visceral pleura or peripheral lung resections. Although highly prevalent with significant consequences, traditional assessment methods lack the capability to objectively quantify air leaks, which further complicates management, results in inconsistent decision making, and prolongs hospital stays. By incorporating the Thopaz+ system, the investigators can introduce a reliable approach to objectively quantify air leaks, potentially improving clinical outcomes.

The purpose of this protocol is to perform a pilot prospective controlled clinical trial to evaluate the utility of incorporating the Thopaz+ system and its volume quantification ability in evaluating patients with persistent air leaks (PALs) to guide treatment decisions, specifically endobronchial valves (EBVs).

In the targeted cohort, the Thopaz+ will be connected to the chest tube and the data collected will be combined with that of serial balloon occlusion testing with a Fogarty balloon to accurately localize the air leak source, and subsequently consider the correct placement of EBVs. The investigators will thereby determine whether this experimental strategy will yield a more accurate and objective assessment of air leaks, facilitating timely interventions and improved patient outcomes.

Conditions

  • Persistent Air Leaks

Interventions

DIAGNOSTIC_TEST

Persistent air leak quantification

In this trial, patients with PALs will have their chest tubes connected to the Thopaz+ system. The Thopaz+ will continuously quantify the volume of air leaks, providing real-time data for analysis. Data from both the Thopaz+ and standard serial occlusion test with Fogarty balloon will be combined and integrated to provide a comprehensive assessment of the air leak source. The bronchoscopic will perform standard visual assessment of changes in air leak during serial balloon occlusion in order to identify the best region for endobronchial treatments; use of measurements from the Thopaz and serial balloon occlusion test will be allowed as part of clinical reasoning but are not required to be used by the treating clinician.

Sponsors & Collaborators

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-01-01
Primary Completion
2026-06-30
Completion
2026-09-30
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.