Trial of Low-intensity Anticoagulation to Reduce GI or Other Bleeding Complications With Equivalent Therapeutic Efficacy in HeartMate 3 LVAD Patients
NCT07081035 · Status: NOT_YET_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 94
Last updated 2025-07-23
Summary
The TARGET trial is a prospective, single-center, randomized, open-label, active-controlled inequality clinical trial designed to evaluate the safety and efficacy of low-intensity anticoagulation therapy (target INR 1.5-2.0) compared to standard anticoagulation therapy (target INR 2.0-3.0) in patients receiving a HeartMate 3 Left Ventricular Assist Device (LVAD).
Despite the demonstrated effectiveness of HeartMate 3 LVAD in reducing thromboembolic complications, standard anticoagulation treatment guidelines recommend maintaining an INR between 2.0 and 3.0, which can lead to a substantial risk of bleeding, especially gastrointestinal (GI) bleeding. Preliminary studies, such as MAGENTUM 1, have indicated potential safety and reduced bleeding events at lower INR targets (1.5-1.9). However, robust evidence through randomized controlled trials is still required.
The primary objective of the TARGET trial is to determine if low-intensity anticoagulation therapy significantly reduces the incidence of major bleeding and thrombotic events compared to standard therapy within 6 months post-randomization. Secondary objectives include evaluating the safety and hematological complications associated with low-intensity anticoagulation.
The study will enroll adult patients aged ≥19 years who have been stably maintained on standard INR therapy (2.0-3.0) for at least 30 days post-HeartMate 3 LVAD implantation. Participants will be randomized in a 1:1 ratio into two groups: the low-intensity INR group (target INR 1.5-2.0) and the standard INR group (target INR 2.0-3.0). Randomization will be stratified based on the presence of atrial fibrillation.
The primary endpoint is a composite of hemocompatibility-related events, including major bleeding, stroke, and pump thrombosis, occurring within 6 months after randomization, as defined by INTERMACS criteria. Secondary endpoints encompass clinical outcomes such as all-cause mortality, cardiac death, LVAD-related thromboembolic events, stroke, systemic embolism, myocardial infarction, major bleeding incidents, and the rate and number of LVAD-related hospital readmissions and reoperations. Additionally, INR management outcomes, including time in therapeutic range (TTR) and frequency of warfarin dose adjustments, will be assessed.
The trial duration is approximately 36 months, including a 24-month enrollment period, a 6-month follow-up period for each participant, and time allocated for data analysis and reporting. Safety will be rigorously monitored by a Data Safety Monitoring Board (DSMB) and Clinical Events Committee (CEC), ensuring participant safety and data integrity throughout the study.
This trial aims to provide critical insights that could optimize anticoagulation strategies in LVAD patients, potentially improving patient safety by reducing bleeding risks without compromising thrombotic event protection.
Conditions
- Advanced Heart Failure
- Left Ventricular Assist Devices
- Anticoagulation Treatment
- Bleeding Complications
- Thrombotic Complications
Interventions
- DRUG
-
Warfarin (low-intensity anticoagulation)
Low-intensity INR group (Experimental): Participants will receive anticoagulation therapy with warfarin, aiming for a reduced INR range of 1.5-2.0, which is lower than the current standard recommendation. Warfarin dosing will be regularly adjusted based on INR monitoring throughout the 6-month study period.
- DRUG
-
Warfarin (standard anticoagulation)
Standard INR group (Active Comparator): Participants will receive anticoagulation therapy with warfarin, maintaining an INR within the standard therapeutic range of 2.0-3.0. Warfarin dosing adjustments will be made regularly according to standard clinical practice and INR monitoring throughout the 6-month study period.
Sponsors & Collaborators
-
Asan Medical Center
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 19 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-10-31
- Primary Completion
- 2028-10-31
- Completion
- 2029-01-31
Countries
- South Korea
Study Locations
More Related Trials
-
Resynchronization for Ambulatory Heart Failure Trial in Patients With Preserved LV Function
NCT04582578 ·Status: WITHDRAWN ·Phase: NA
-
Randomized Evaluation for Failed TAVR
NCT06400342 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement
NCT01240902 ·Status: COMPLETED ·Phase: NA
-
VentrAssistTM LVAD as a Bridge to Cardiac Transplantation - Feasibility Trial
NCT00490347 ·Status: COMPLETED ·Phase: PHASE2
-
Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device (LVAD) and Medical Management
NCT01452802 ·Status: COMPLETED
-
Transcatheter Tricuspid Valve Replacement With the Medtronic Intrepid™ Transcatheter Tricuspid Valve Replacement (TTVR) System in Severe Tricuspid Regurgitation
NCT07321899 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Clinical Trial to Evaluate the HeartWare MVAD® System (MVAdvantage)
NCT01831544 ·Status: TERMINATED ·Phase: NA
-
DEFLECT II: A Study to Evaluate the Safety and Performance of the TriGuard™HDH in Patients Undergoing TAVR
NCT02073851 ·Status: COMPLETED ·Phase: NA
-
VentrAssistTM LVAD as a Bridge to Cardiac Transplantation - Pivotal Trial
NCT00483197 ·Status: UNKNOWN ·Phase: PHASE3
-
Evaluation of Platelet Therapy Response in Left Ventricular Assist Device Patients
NCT06152562 ·Status: COMPLETED
-
VentrAssistTM LVAD for the Treatment of Advanced Heart Failure - Destination Therapy
NCT00490321 ·Status: UNKNOWN ·Phase: PHASE3
-
Percutaneous RVAD to Preemptively Treat Right Heart Failure Post-LVAD
NCT04458103 ·Status: TERMINATED ·Phase: NA
-
Pacemaker Implantation Following Transcatheter Tricuspid Valve Replacement
NCT06814574 ·Status: RECRUITING
-
U.S. Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
NCT06069661 ·Status: WITHDRAWN ·Phase: NA
-
Medtronic Transcatheter Aortic Valve Replacement (TAVR) Low Risk Bicuspid Study
NCT03635424 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Conservative Management of Left Ventricular Assist Device Candidates
NCT05271214 ·Status: RECRUITING
-
Clinical Evaluation of Percutaneous Implantation of the Medtronic CoreValve Aortic Valve Prosthesis (18Fr-Study)
NCT01051518 ·Status: COMPLETED ·Phase: NA
-
The Evaluation of Thrombogenicity in Patients Undergoing WATCHMAN Left Atrial Appendage Closure Trial
NCT03040622 ·Status: COMPLETED
-
Clinical Trial to Evaluate the the ReliantHeart HeartAssist 5® VAD System in Patients Awaiting Heart Transplantation
NCT02205411 ·Status: TERMINATED ·Phase: NA
-
TTVR Early Feasibility Study
NCT04433065 ·Status: RECRUITING ·Phase: NA
-
Optimization of Heart Failure (HF) Medical Therapy After Transcatheter Valve Intervention (TVI) in Patients With Heart Failure With Reduced Ejection Fraction (HFrEF)
NCT06667128 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Aachen Safety and Efficacy of the Percutaneous Transvenous Mitral Annuloplasty Device to Reduce Mitral Regurgitation
NCT00572091 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Noninferiority Trial of MitraClip Implantation Strategies: 1 Clip vs. 2 Clips in Patients With Functional Mitral Regurgitation
NCT03503851 ·Status: WITHDRAWN ·Phase: NA
-
Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
NCT05893082 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of HW005 Ventricular Assist System for the Treatment of Advanced Heart Failure in Japan
NCT02091440 ·Status: COMPLETED ·Phase: NA