WATCH (Wearable Artificial inTelligence for Cardiac Function and Health Monitoring)
NCT07058064 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 250
Last updated 2025-10-15
Summary
The purpose of this study is to find a cost effective cardiovascular (CV) surveillance of cancer survivors over long periods of time to prevent the risk of progression of heart failure (HF) and related morbidity and mortality. Mobile device-based artificial intelligence (AI)-electrocardiogram (ECG) can reliably detect cardiac dysfunction in lymphoma and sarcoma survivors and smart watch based surveillance for cardiotoxicity is feasible and reliable.
Conditions
- Lymphoma
- Sarcoma
Interventions
- PROCEDURE
-
Electrocardiogram
All participants receive a standard 12-lead ECG when they present for follow-up 1 year after completion of anthracycline-based therapy. All participants will also record a 6-lead Kardia (AliveCor, Mountain View, CA, USA) and 1-lead Apple Watch (Apple, Cupertino, CA, USA) ECG with Mayo-owned or participant-owned devices. Longitudinal participants will receive an Apple Watch to use during this study if they do not have their own (and agree to download the app) and will be able to transmit ECGs anytime anywhere from their Apple Watch from before the initiation, all through the treatment, up to 1-year after anthracycline-based therapy. For validation, these participants will transmit ECGs from their smart watch at the time of routine follow-up visits (at 3-, 6- \& 9-months post therapy visits) along with 6-lead Kardia ECGs, and 12-lead standard ECGs.
- PROCEDURE
-
Echocardiogram
All participants will have an echocardiogram as part of standard of care when they present for their follow-up 1 year after completion of anthracycline-based therapy.
- PROCEDURE
-
LVEF echocardiogram
Participants will undergo a limited LVEF echocardiogram at the 6-month post therapy visit.
- OTHER
-
Apple Watch
Longitudinal participants will receive an Apple Watch to use during this study if they do not have their own (and agree to download the app) and will be able to transmit ECGs anytime anywhere from their Apple Watch from before the initiation, all through the treatment, up to 1-year after anthracycline-based therapy. For validation, these participants will transmit ECGs from their smart watch at the time of routine follow-up visits (at 3-, 6- \& 9-months post therapy visits) along with 6-lead Kardia ECGs, and 12-lead standard ECGs. Longitudinal participants will be asked to transmit weekly cardio fitness (estimates of peak VO2) from baseline to 1-year post therapy.
- PROCEDURE
-
Biospecimen collection
Undergo blood draw
- OTHER
-
Questionnaires
Participants fill out 2 questionnaires: 1) the Kansas City Cardiomyopathy-12 (KCCQ-12) Questionnaire, and 2) the European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire (QLQ) ore 30 (EORTC QLQ-C30) to evaluate health related quality of life and heart failure symptoms.
- OTHER
-
Cardio-pulmonary exercise test
Undergo CPET to assess the response of heart and lungs to exercise.
- OTHER
-
6 minute walk test
Complete a 6MWT, to see how far participants can walk on a hard, flat surface for 6 minutes
- OTHER
-
Grip strength test
A hand-held device called a dynamometer will be used to measure the muscle strength in hand/forearm
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Joerg Herrmann, MD · Mayo Clinic
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SCREENING
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-07-18
- Primary Completion
- 2029-06-29
- Completion
- 2029-06-29
Countries
- United States
Study Locations
More Related Trials
-
Comparison of QT Interval Readings Between Smartwatch Combined With Cardiologs Artificial Intelligence and 12-lead ECG
NCT05161065 ·Status: COMPLETED
-
An Evaluation of Concordance of Smartwatch ECG and One Clinical ECG and Comparison of The Two ECGS in Terms of Predictive Risks
NCT05617391 ·Status: ACTIVE_NOT_RECRUITING
-
Wearable Activity Tracking to Curb Hospitalizations
NCT06587100 ·Status: RECRUITING
-
A Study on the Effectiveness of the Application of an Artificial Intelligence Algorithm for Calibrating PPG With ECG to Improve the Accuracy of Atrial Fibrillation Burden Estimation
NCT06552468 ·Status: COMPLETED
-
Smart Home Care of Cloud Base ECG on the Cardiotoxicity Prevention on the Cancer Patients.
NCT04885088 ·Status: UNKNOWN
-
Heart Watch Study: a Pragmatic Randomized Controlled Trial
NCT04468321 ·Status: COMPLETED ·Phase: NA
-
Smartwatch Paroxysmal Arrhythmia Detection Compared with Holter
NCT06425887 ·Status: RECRUITING
-
Accuracy of Rhythm Detection by a Wearable Smart Watch for Cardiac Arrhythmias (The WATCH-RHYTHM Study)
NCT04499807 ·Status: TERMINATED ·Phase: NA
-
Wearable ECG for AF Screening and Stroke Risk Assessment
NCT06907264 ·Status: NOT_YET_RECRUITING
-
Atrial Fibrillation Detection Using Garmin Wearable Technology
NCT03566836 ·Status: UNKNOWN
-
Wearable Assessment of Thoracic, Cardiac Health and Exercise Performance Trial
NCT06671171 ·Status: COMPLETED
-
Continuous Data Collection and Analysis for Stroke Prevention Using a Wearable Sensor
NCT03441022 ·Status: WITHDRAWN ·Phase: NA
-
Detection and Quantification of Atrial Fibrillation in High-risk Patients Using a Smartwatch Wearable (Apple Watch)
NCT05686330 ·Status: COMPLETED ·Phase: NA
-
Smart Watch Insights for Prevention of Exacerbations and Enhance Rehabilitation - Movement Study
NCT06011356 ·Status: ACTIVE_NOT_RECRUITING
-
Assessment of the BodyGuardian Remote Monitoring Platform in Elderly Healthy Subjects
NCT01808053 ·Status: COMPLETED
-
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
NCT03761394 ·Status: COMPLETED ·Phase: NA
-
Automated Diagnostic Performance of Smartwatch ECG for Arrhythmia Detection Using the PulseAI Neural Network.
NCT05668377 ·Status: UNKNOWN
-
Continuous Wireless Monitoring of Vital Signs and Automated Alerts in Participants at Home and During Hospitalization
NCT05378139 ·Status: RECRUITING
-
Accuracy of Cardiac Wearables Devices to Detect Atrial Fibrillation
NCT04809922 ·Status: COMPLETED
-
Screening for Heart Failure Using a Multimodal Wearable Device
NCT06335264 ·Status: COMPLETED
-
Clinical Performance of Withings Move ECG Software for Atrial Fibrillation Detection
NCT04493749 ·Status: ACTIVE_NOT_RECRUITING
-
Enhanced Monitoring for Better Recovery and Cancer Experience in Greater Manchester
NCT05099237 ·Status: UNKNOWN ·Phase: NA
-
Telematics Device for Daily Monitoring of Vital Signs in Cancer
NCT05650814 ·Status: UNKNOWN ·Phase: NA
-
Wearable Devices Empowering Active Health Initiatives for High-Risk Stroke Populations
NCT06935513 ·Status: RECRUITING ·Phase: NA
-
Wearable and Patient-reported Outcome-based Continuous Assessment and Support Alerts in Palliative Care
NCT05273580 ·Status: COMPLETED