Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms
NCT07019454 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 15
Last updated 2025-06-13
Summary
Patients who are found to have an aneurysm (bulge) in the abdominal aorta, which is the blood vessel in your abdomen (belly) that supplies blood to most of your lower body, including major organs and your legs. As an aneurysm expands, the walls of the aorta become weak and may rupture (break open), causing a major loss of blood with a high risk of serious problems and death. To avoid this risk, doctors repair aneurysms by either open surgery (incision) or endovascular surgery (covered stents to channel the blood flow). Juxtarenal aneurysms (those that come close to the kidney arteries) present a unique challenge as they are more dangerous to repair by open therapy and do not fit the standard approved endovascular devices. The purpose of this study is to assess the effects of the physician-modified endovascular graft (PMEG) by collecting information about the performance of this investigational medical device.
The main graft looks like a pair of pants with very short legs. The top of the pants is placed in the aorta. Then, two smaller grafts go from the main graft and to your iliac arteries (the main arteries supplying blood to your abdomen and legs) to form the legs of the pair of pants. Each graft is packed into a small catheter (a long, flexible plastic tube) that is placed into your aorta through the femoral artery in your groin (top of your leg). The grafts are then placed in the correct position in your aorta by releasing them from the catheters. These grafts are investigational because the research physician has changed them to match patient anatomy (body make up) while protecting blood flow to important vessels. Once the grafts are attached inside the aorta, they will support the area of the aorta that is weakened and bulging.
Modifications of the graft will include between one and four holes (fenestrations) near the top of the graft. The holes allow the graft to be located above the renal arteries (the blood vessels that supply blood to your kidneys) without blocking the blood flow to them. One or more of the arteries will also be treated with a stent (metal wire tube) to help keep the arteries open and to keep the arteries connected to the holes that are made for the graft.
The device is custom modified for patient specific anatomy. The information collected from this study will be used to show how well patients do when treated with the modified graft, both immediately after surgery and over a long period of time. After the procedure, labs, CT imaging with contrast, XRays and ultrasounds will be done to check the graft at intervals 1 month, 6 months, 12 months and yearly for 5 years. These are standard surveillance studies performed on any endovascular aneurysm repair.
Conditions
- Technical Sucess
- Freedom From Type I and III Endoleaks at 12 Months
- Freedom From Stent Graft Migration at 12 Months
- Freedom From Aortic Aneurysm Enlargement at 12 Months
- Freedom From Aortic Aneurysm Rupture or Conversion to Open Repair at 12 Months
Interventions
- DEVICE
-
Physician Modified Endografting
This is the only intervention in the study
Sponsors & Collaborators
-
Baystate Medical Center
lead OTHER
Principal Investigators
-
Hazel Marecki, MD · Baystate Medical Center
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-06-03
- Primary Completion
- 2030-06-03
- Completion
- 2035-06-03
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Physician-modified Endovascular Graft for Repair of Complex Thoracoabdominal and Abdominal Aortic Aneurysms
NCT04526938 ·Status: SUSPENDED ·Phase: NA
-
University of Utah PS-IDE: Physician Modified Endovascular Grafts for the Treatment of Elective, Symptomatic or Ruptured Juxtarenal Aortic Aneurysms
NCT07065760 ·Status: RECRUITING ·Phase: NA
-
Clinical Outcomes and Major Adverse Events in Patients Treated With Physician-Modified Fenestrated and Branched Stent Grafts
NCT06526676 ·Status: RECRUITING ·Phase: NA
-
Physician Modified Endograft For Complex Aortic Aneurysm Repair
NCT05339061 ·Status: RECRUITING ·Phase: NA
-
Standardization of Physician-Modified Stent Grafts for Abdominal Aortic Aneurysms
NCT06585215 ·Status: ENROLLING_BY_INVITATION
-
Endovascular Repair With Fenestrated TREO Stent-Graft System in AAA
NCT07026877 ·Status: RECRUITING ·Phase: NA
-
Physician-Modified Fenestrated and Branched Aortic Endografting for TAAA
NCT02989948 ·Status: RECRUITING ·Phase: NA
-
Feasibility of Endovascular Repair Of Ascending Aortic Pathologies
NCT02201589 ·Status: RECRUITING ·Phase: NA
-
Physician Modified Endovascular Grafts for the Treatment of Juxtarenal Aortic Aneurysms
NCT06657794 ·Status: RECRUITING ·Phase: NA
-
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
NCT02009644 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Feasibility and Safety Study of the Endologix Fenestrated Stent Graft System
NCT01348828 ·Status: COMPLETED ·Phase: NA
-
Early Feasibility of the Branched TAG® Device in the Treatment of Aortic Arch Aneurysms
NCT02264977 ·Status: COMPLETED ·Phase: NA
-
PMEG for Repair of Pararenal and Thoracoabdominal Aortic Aneurysm
NCT05195905 ·Status: RECRUITING ·Phase: NA
-
Complex Aortic Aneurysm Repair Using Physician Modified Endografts and Custom Made Devices
NCT02050113 ·Status: RECRUITING ·Phase: NA
-
Safety and Effectiveness of Physician-Modified Fenestrated and Branched Aortic Endografting for the Treatment of Thoracoabdominal and Pararenal Aortic Aneurysms
NCT06501872 ·Status: RECRUITING ·Phase: NA
-
Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks
NCT04227054 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Prevention of Endoleaks Using Autologous Platelet Gel on Unruptured Abdominal Aortic Aneurysms
NCT00372138 ·Status: TERMINATED ·Phase: NA
-
Treovance Stent-Graft With Navitel Delivery System for Patients With Infrarenal Abdominal Aortic Aneurysms
NCT01328197 ·Status: COMPLETED ·Phase: PHASE1
-
Thoracoabdominal Aortic Stent System for Endovascular Treatment of Thoracoabdominal Aortic Dissecting Aneurysm.
NCT05803564 ·Status: RECRUITING ·Phase: NA
-
False Lumen Treatment for Prevention of Aortic Growth Using Shape Memory Polymer - First-in-Human Study
NCT06550986 ·Status: RECRUITING ·Phase: NA
-
Endovascular Treatment of TAAA and Aortic Arch Aneurysms Using Fenestrated and Branched Stent Grafts
NCT02323581 ·Status: RECRUITING ·Phase: NA
-
Clinical Study of the TriVascular Ovation™ Abdominal Stent Graft System
NCT01092117 ·Status: COMPLETED ·Phase: NA
-
Safety, Efficacy, Longitudinal Costs and Patient-Centered Outcomes Using a TAAA Debranching Device
NCT03637374 ·Status: TERMINATED ·Phase: NA
-
Branched Aortic Arch Study
NCT00488696 ·Status: WITHDRAWN ·Phase: NA
-
Protected Carotid Artery Stenting in Subjects at High Risk for Carotid Endarterectomy (CEA) (PROTECT)
NCT00402740 ·Status: COMPLETED ·Phase: NA