With the advancement of the digital age, dentistry has been one of the fields that has benefited most from technological innovations. Among these advancements, digital intraoral scanners, which precisely capture the three-dimensional geometry of objects, have become widely used, particularly in prosthodontics and orthodontics. The increasing integration of digitalization in pediatric dentistry has also improved treatment processes, making them more efficient and comfortable for both patients and clinicians.
Previous studies comparing conventional and digital impression techniques suggest that patients generally prefer digital scanning due to improved comfort and reduced procedural time. However, research on pediatric patients remains limited, with most studies focusing on general performance rather than specific patient experiences. Given the unique anatomical and psychological characteristics of children, a comprehensive evaluation of comfort perception in different intraoral scanners is necessary.
This study aims to assess the effects of two different intraoral scanners on pediatric patients' comfort perception. It is designed as a single-center, randomized controlled crossover study, approved by the Ethics Committee of the Faculty of Dentistry at Batman University. A total of 68 children meeting the inclusion criteria were recruited and randomly assigned to undergo intraoral scanning with two different devices (IteroTM and 3ShapeTM) at separate visits. Comfort levels were assessed using the Animale Emoji Scale (AES), a validated tool for measuring children's emotional responses to procedures.
By comparing the comfort perception of different intraoral scanners in pediatric patients, this study aims to provide evidence-based guidance for clinicians in selecting the most patient-friendly digital impression techniques, ultimately improving patient experience and clinical workflow in pediatric dentistry.
To prevent bias during the procedure, the intraoral scan was performed using either the Itero™ or 3Shape™ device, determined by simple randomization. Since the sample consisted of consecutive cases, random selection was performed by coin toss.
At the first appointment, parents or legal guardians were informed about the study, a consent form was provided, and they were informed that they would be contacted again if they wished to participate. The first scan was performed using the Itero Element 2D (Align Technology, San Jose, CA, USA) device.
The second appointment was scheduled 7 to 30 days after the initial appointment to avoid affecting children's comfort, in accordance with previous studies. The second scan was planned using the 3Shape Trios 3 (3Shape, Copenhagen, Denmark) device.
All intraoral scans were performed by the principal investigator of the study. According to the manufacturer's instructions, the patient was scanned in a supine position following the same sequence (lower jaw, upper jaw, and bite registration).
To increase the reliability of the results, all measurements were taken by a single experienced researcher who took at least 100 measurements with both scanning devices. To ensure standardization, all patients were positioned at 11 o'clock relative to the unit and the scanning device was positioned at 1 o'clock for all scans.
The primary outcome of the study was patient comfort. Participants' comfort was measured using the Animated Emoji Scale (AES) based on questions prepared during the procedure. Children were asked to select the face that best reflected their feelings after the procedure (Figure 1). For younger children, the AES scale was completed under the supervision of the operator and with guiding questions. The AES scale includes 6 different facial expressions ranging from "no pain" to "worst pain," and each face is scored from 0-2-4-6-8-10. These measurements were always taken by the same observer.
Sample size was calculated using G\*Power, and data analysis was performed using IBM SPSS 21® Software (Armonk, NY, USA). The normality of the data was evaluated using the Shapiro-Wilk's and/or Kolmogorov Smirnov tests. The significance level was set at p\<0.05. In case of deviation from the normal distribution, differences between groups were examined using the Mann Whitney U and Kruskal Wallis-H tests. In case of a significant difference in the Kruskal Wallis-H test, a Post-Hoc multiple comparison test was applied. Differences between two dependent variables were analyzed using the Wilcoxon test.
Conditions
- Intraoral Scanner
Interventions
- DEVICE
-
Intraoral Scanners
Intraoral scanners for pediatric patients
Sponsors & Collaborators
-
Batman University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 8 Years
- Max Age
- 12 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-11-01
- Primary Completion
- 2025-01-15
- Completion
- 2025-02-15
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Intraoral Scanners as Periodontal and Dental Pathologies Diagnosis Tools
NCT06006429 ·Status: RECRUITING ·Phase: NA
-
Digital Occlusal Analysis and Bite Force Evaluation of Primary Molars Restored With Zirconia Crowns Using T-Scan
NCT07276841 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Digital Quantification of Dental Plaque Based on Intraoral Scanner Images
NCT07152314 ·Status: NOT_YET_RECRUITING
-
Deviation Parameters of Intraorfal Scanning in Capturing Different Intraoral Defects
NCT06315621 ·Status: COMPLETED ·Phase: NA
-
Digital Occlusal Analysis of Ultra Suction Retained Complete Denture
NCT04999579 ·Status: COMPLETED ·Phase: NA
-
Space Changes After Premature Loss of Lower First Primary Molars in Children Using Digital Scanning
NCT06965777 ·Status: NOT_YET_RECRUITING
-
Repetition Improves Precision and Trueness of Digital Intraoral Scans
NCT02868957 ·Status: COMPLETED ·Phase: NA
-
Prevalence of Constructed Space Maintainers in a Group of Egyptian Children
NCT03027765 ·Status: UNKNOWN
-
Impact of Atraumatic Restorative Treatment and Oral Health Promotion on Psychological and Salivary Aspects of Children
NCT03100773 ·Status: COMPLETED ·Phase: NA
-
Tooth Wear Monitoring Using Intraoral Scanner
NCT05843513 ·Status: COMPLETED
-
Trueness of Digital Occlusal Analysis
NCT06672627 ·Status: ACTIVE_NOT_RECRUITING
-
3D Scanning as an Advanced Tool for Identifying Tooth Lesions in Children
NCT06829550 ·Status: COMPLETED ·Phase: NA
-
Pain in Pediatric Dentistry - a Grounded Theory Study on the Experiences of Dental Professionals and Students
NCT04643951 ·Status: RECRUITING
-
A Comparative Clinical Study of Different Caries Removal Techniques in Pediatric Patients
NCT04591418 ·Status: COMPLETED ·Phase: NA
-
The Effectiveness of iTero Element 5D NIRI System in Early Proximal Caries Detection in Permanent Teeth
NCT06276959 ·Status: RECRUITING
-
Digital Occlusal Analysis and Bite Force Evaluation of the Hall Technique Vs Stainless Steel Crowns in Primary Molars Using T-scan
NCT07295574 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Accuracy of Digital Models Obtained Using Intraoral and Extraoral Scanners
NCT03103802 ·Status: UNKNOWN ·Phase: NA
-
Effect of 980nm Diode Laser on Postoperative Pain and Root Canal Disinfection in Endodontic Retreatment Cases
NCT03711357 ·Status: UNKNOWN ·Phase: NA
-
Effect of VR vs Screens on Children's Dental Anxiety, Pain and Behavior
NCT05157438 ·Status: RECRUITING ·Phase: NA
-
Clinical Evaluation of Compomer and Composite Class II Restorations in Primary Molars: 24 Months Results
NCT04678141 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Caries Detection Methods
NCT05064566 ·Status: UNKNOWN
-
Impact of Detecting Initial and Active Caries Lesions in Primary Teeth
NCT02473107 ·Status: COMPLETED ·Phase: NA
-
Effect of Computer-controlled vs. Conventional Injection on Pain and Anxiety in Children
NCT07193342 ·Status: COMPLETED ·Phase: NA
-
Accuracy Of Detection Of Dental Caries From Intraoral Images Using Different ArtificiaI Intelligence Models
NCT06749743 ·Status: NOT_YET_RECRUITING
-
Effect of Low Level Laser Therapy on Post-endodontic Pain
NCT03748498 ·Status: COMPLETED ·Phase: NA