Effect of Low-Flow Anesthesia in Single Lung Ventilation on Postoperative Respiratory Complications
NCT06838091 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 68
Last updated 2025-05-07
Summary
Mechanical ventilation in thoracic surgery patients is often complicated because patients are usually in the lateral decubitus position and the operated lung is intermittently deflated to facilitate surgical exposure . Single-lung ventilation during thoracic surgery is prone to volutrauma, barotrauma, atelectrauma, and oxygen toxicity, which are important aspects of ventilator-associated lung injury (VILI) . In studies conducted on operated patients, the use of lung-protective ventilation, including low tidal volume (6-8 ml/kg), respiratory rate, driving pressure (DP), and positive end-expiratory pressure (PEEP) application, has been recommended in the perioperative period to reduce postoperative pulmonary complications. Optimum oxygenation should be provided to patients during the intraoperative period, avoiding the harmful effects of hypoxia and hyperoxia. This situation becomes even more important in single-lung ventilation. Fresh gas flow in anesthesia systems can be done with traditional high-flow, normal-flow, or low-flow strategies according to the clinician's preference. The interest in the anesthesia method with low fresh gas flow has increased all over the world and in our country. The development of the technology of the anesthesia devices used, the increase in knowledge about the content of inhaled gases, and the availability of monitors that continuously and thoroughly analyze the anesthetic gas composition have facilitated the use of low-flow anesthesia safely.
When the literature is evaluated, it is defined as 4 lt/min and above as very high flow, 2-4 lt/min as high flow, 1-2 lt/min as medium flow, 0.5-1 lt/min as low flow, 0.25-0.5 lt/min as minimal flow, and \<0.25 lt/min as metabolic flow . High flow has now been abandoned due to both cost and environmental pollution.
Low-flow anesthesia creates a breath air closer to physiological conditions during anesthesia by heating and humidifying the inhaled gases. In addition, it provides a cost advantage by reducing inhalation agent consumption and reduces atmospheric pollution . It is suggested that the use of both fresh gas flow rates does not pose a safety risk for patients, and in fact, the use of low-flow anesthesia methods should be made more widespread with the advantages it provides. Low-flow anesthesia is a method applied during general anesthesia using a rebreathing anesthesia system, where the rebreathed fresh oxygen flow rate is at least 50%, metabolic requirements are fully met and sufficient volatile matter can be administered. In our clinic, the fresh gas flow rate during general anesthesia is routinely used at a value between 0.5 lt/min-3 lt/min, depending on the clinician's preference. In our clinic, low-flow anesthesia methods (with varying flows) are routinely applied in addition to normal flow methods in many surgical practices.
Although low-flow anesthesia techniques are used in many surgical practices, the literature is limited in surgeries where single-lung ventilation is performed. The purpose of this study is to determine the anesthetic flows used in amounts ranging from 0.5 lt/min-3 lt/min in thoracic surgeries where single-lung ventilation is performed; to evaluate the effects on perioperative hemodynamic and respiratory parameters and respiratory complications. The secondary aim of the study is to show the consumption of inhalation agent and soda lime.
Conditions
- Thoracic Surgery
- Low-flow Anesthesia
Interventions
- OTHER
-
Observational
During anesthesia administration: T0, T1, T2, T3, T4 represent the following periods: T0: Double lumen ventilation in the supine position immediately after intubation T1: Double lumen ventilation in the lateral position T2: Single lumen ventilation in the lateral position (with the chest wall closed) T3: Single lumen ventilation in the lateral position (with the chest wall open) T4: Just before extubation 1. Airway pressure (P plateau, Ppeak) values from the anesthesia device data, 2. BIS (from routine BIS monitoring) 3. Temperature (Routinely from pharyngeal temperature probe), 4. Oxygen saturation (Routinely from the patient monitor) 5. End-tidal CO₂, 6. Inspiratory O₂ concentration, 7. Inspiratory CO2 concentration, 8. Inspiratory and expiratory desflurane/sevoflurane concentrations, 9. Tidal volume, 10. MAC, routinely from anesthesia device data 11. Blood Gas Analysis (COHgb, Ph, PO 2 , PCO 2 , SaO 2, HCO 3 , Base deficit, glucose, lactate)
Sponsors & Collaborators
-
Başakşehir Çam & Sakura City Hospital
lead OTHER_GOV
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-03-01
- Primary Completion
- 2025-05-01
- Completion
- 2025-05-02
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Oxygen Reserve Index in One-Lung Ventilation During Elective Thoracic Operations
NCT05050552 ·Status: COMPLETED
-
Low and Moderete Flow Anaesthesia on Haemodynamics
NCT06871371 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Effects of Different Fresh Gas Flows on Carboxyhemoglobin Levels and Postoperative Patient Outcomes in Pediatric Cardiovascular Surgery
NCT06097806 ·Status: RECRUITING
-
Effect of Low Tidal Volume Ventilation on Postoperative Delirium
NCT06752421 ·Status: COMPLETED ·Phase: NA
-
Minimal Flow Application in One Lung Ventilation
NCT04376307 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Regional Anesthesia Techniques on Brain Tissue Oxygenation in Thoracic Surgery
NCT04373174 ·Status: COMPLETED ·Phase: NA
-
the Effect of Different Mechanical Ventilation Modes on Optic Nerve Diameter and Conscious Functions
NCT04413903 ·Status: COMPLETED ·Phase: NA
-
The Effect of Flow-controlled Ventilation on Hemodynamic and Respiratory Parameters in Laparoscopic Surgeries
NCT06274372 ·Status: COMPLETED ·Phase: NA
-
Hemodynamic Effects of Ventilation Modes
NCT03684291 ·Status: UNKNOWN
-
Feasibility and Safety Properties of Metabolic Flow Anesthesia Driven by Automated Gas Control in Pediatric Patients
NCT05644340 ·Status: COMPLETED ·Phase: NA
-
Low Flow Anesthesia in Morbid Obesity
NCT03913858 ·Status: COMPLETED ·Phase: NA
-
Effects of Different Anesthetic Gases on Hemodynamics, Arterial Oxygenation and Pulmonary Mechanics
NCT06118489 ·Status: COMPLETED
-
Evaluation of the Effects of Different Ventilation Modes Used During Anesthesia Awakening on the Frequency of Postoperative Atelectasis
NCT06358027 ·Status: NOT_YET_RECRUITING
-
Local Assessment of Ventilatory Management During General Anesthesia for Surgery
NCT01601223 ·Status: COMPLETED
-
Evaluation of Fluid Responsiveness With Recruitment Maneuver After Sternotomy in Coronary Artery Bypass Surgery
NCT06249568 ·Status: RECRUITING
-
Effect of Chest Tube Withdrawal on Patients' Anxiety Levels After Thoracic Surgery
NCT06531928 ·Status: RECRUITING
-
Cerebral and Peripheral Near Infrared Spectroscopy Monitoring in Low and High Flow Anaesthesia in Pediatric
NCT06320743 ·Status: COMPLETED ·Phase: NA
-
Comparison of Airway Management With Bronchial Blocker and Double-Lumen Tube in Single-Lung Ventilation
NCT06299735 ·Status: COMPLETED ·Phase: NA
-
Lung Protection Strategy in Open Heart Surgery: Which Tidal Volume is Better 8ml/kg or 6ml/kg
NCT03651817 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-Based Airway Assessment for Predicting Difficult Intubation in Adult Female Patients
NCT07343557 ·Status: COMPLETED
-
The Role of Existing Formulas in the Double-lumen Tube in Thoracic Surgery Anesthesia
NCT07191002 ·Status: RECRUITING
-
The Affecting Factors on Airway Temperature and Moisture
NCT04204746 ·Status: COMPLETED
-
The Effect of Single Lung Ventilation Duration on Postoperative Pulmonary Complications in Thoracic Surgery
NCT07100860 ·Status: RECRUITING
-
Is Low Flow Anaesthesia Feasible?
NCT06389669 ·Status: COMPLETED
-
Prediction of Difficult Airway in Cesarean Section Using Preoperative Airway Assessment Tests
NCT07340346 ·Status: COMPLETED