Trial Outcomes & Findings for Effect of Black Tea Extract Impregnated Gauze on Extracted Socket (NCT NCT06687824)

NCT ID: NCT06687824

Last Updated: 2025-05-20

Results Overview

A stopwatch is used by the investigator to check the bleeding status of the extracted socket at 2, 5 and 7 minutes after compression of the socket with black tea extract-impregnated gauze or color-blinded sterile gauze

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

44 participants

Primary outcome timeframe

Primary bleeding cessation after extraction of molar is assessed up to 7 minutes

Results posted on

2025-05-20

Participant Flow

Participant milestones

Participant milestones
Measure
0.5% Povidone Iodine Impregnated Sterile Gauze
5ml of 0.5% of povidone iodine solution is used for each gauze.
Black Tea-Extract Impregnated Sterile Gauze
5ml of black tea extract solution is used for each gauze with 18.67mg.ml tannin concentration.
Overall Study
STARTED
22
22
Overall Study
COMPLETED
22
22
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Race and Ethnicity were not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
0.5% Povidone Iodine Impregnated Sterile Gauze
n=22 Participants
5ml of 0.5% of povidone iodine solution is used for each gauze.
Black Tea-Extract Impregnated Sterile Gauze
n=22 Participants
5ml of black tea extract solution is used for each gauze with 18.67mg.ml tannin concentration.
Total
n=44 Participants
Total of all reporting groups
Age, Customized
less than 21 years old
1 Participants
n=22 Participants
5 Participants
n=22 Participants
6 Participants
n=44 Participants
Age, Customized
21-30
1 Participants
n=22 Participants
3 Participants
n=22 Participants
4 Participants
n=44 Participants
Age, Customized
31-40
2 Participants
n=22 Participants
3 Participants
n=22 Participants
5 Participants
n=44 Participants
Age, Customized
41-50
6 Participants
n=22 Participants
2 Participants
n=22 Participants
8 Participants
n=44 Participants
Age, Customized
51-60
6 Participants
n=22 Participants
4 Participants
n=22 Participants
10 Participants
n=44 Participants
Age, Customized
more than 60 years old
6 Participants
n=22 Participants
5 Participants
n=22 Participants
11 Participants
n=44 Participants
Sex: Female, Male
Female
11 Participants
n=22 Participants
18 Participants
n=22 Participants
29 Participants
n=44 Participants
Sex: Female, Male
Male
11 Participants
n=22 Participants
4 Participants
n=22 Participants
15 Participants
n=44 Participants
Race and Ethnicity Not Collected
0 Participants
Race and Ethnicity were not collected from any participant.

PRIMARY outcome

Timeframe: Primary bleeding cessation after extraction of molar is assessed up to 7 minutes

A stopwatch is used by the investigator to check the bleeding status of the extracted socket at 2, 5 and 7 minutes after compression of the socket with black tea extract-impregnated gauze or color-blinded sterile gauze

Outcome measures

Outcome measures
Measure
0.5% Povidone Iodine Impregnated Sterile Gauze
n=22 Participants
5ml of 0.5% of povidone iodine solution is used for each gauze.
Black Tea-Extract Impregnated Sterile Gauze
n=22 Participants
5ml of black tea extract solution is used for each gauze with 18.67mg.ml tannin concentration.
Evaluation of the Effect of Black Tea Extract-Impregnated Gauze on Primary Bleeding Cessation After Molar Extraction
less than 2 minutes
17 Participants
12 Participants
Evaluation of the Effect of Black Tea Extract-Impregnated Gauze on Primary Bleeding Cessation After Molar Extraction
2-5 minutes
4 Participants
10 Participants
Evaluation of the Effect of Black Tea Extract-Impregnated Gauze on Primary Bleeding Cessation After Molar Extraction
6-7 minutes
1 Participants
0 Participants

SECONDARY outcome

Timeframe: 3 days post-extraction

Evaluate the presence of adverse effect 3 days after extraction via phone

Outcome measures

Outcome measures
Measure
0.5% Povidone Iodine Impregnated Sterile Gauze
n=22 Participants
5ml of 0.5% of povidone iodine solution is used for each gauze.
Black Tea-Extract Impregnated Sterile Gauze
n=22 Participants
5ml of black tea extract solution is used for each gauze with 18.67mg.ml tannin concentration.
To Identify Adverse Effect of Black Tea-extract Impregnated Sterile Gauze and 0.5% Povidone Iodine Impregnated Sterile Gauze on Post-extraction Sites.
Not present
22 Participants
22 Participants
To Identify Adverse Effect of Black Tea-extract Impregnated Sterile Gauze and 0.5% Povidone Iodine Impregnated Sterile Gauze on Post-extraction Sites.
present
0 Participants
0 Participants

Adverse Events

0.5% Povidone Iodine Impregnated Sterile Gauze

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Black Tea-Extract Impregnated Sterile Gauze

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Heng Sy Xuan

Manipal University College Malaysia

Phone: +601110752589

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place