Outcomes of High Vs Physiological Intraocular Pressure During Cataract Surgery Using ACTIVE SENTRY
NCT06611670 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 38
Last updated 2024-09-25
Summary
Cataract surgery is a widely performed procedure across the world that helps restore vision in many patients suffering from cataracts. Irrigation is an essential component of the surgery. Fluid is constantly circulated to help regulate temperature as heat is generated with ultrasound energy, to minimize tissue trauma, and to create an intraocular pressure (IOP) sufficient to keep the anterior chamber (AC) stable. In parallel, aspiration brings the components of the cataract closer to the surgical instrument. A balance between irrigation and aspiration during surgery is essential to maintain stability in the AC. However, an ideal flow rate, which influences IOP during surgery, is yet to be determined. Most recent studies with Centurion Active Sentry show that there is similar efficiency between higher and lower IOP settings. Traditionally, high-flow rates have been used in advanced cataracts and are believed to make space in the AC. However, they are known to create fluid turbulence and are associated with risks of tissue damage, including cell loss in one of the cornea's layers. High IOP during surgery has also been shown to cause damage to the optic nerve as well as to the retina. Distorting and stretching the AC during phacoemulsification have also been associated with increased pain experienced by the patient. Comfort can be achieved by lowering pressure levels. Low-flow rates have a better safety profile, reduce IOP and pressure fluctuations while offering equal efficiency, including comparable surgical time. Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively as opposed to patients in the high-flow rates. As less fluid turbulence is created with low-flow rates, there is decreased risk of fragment contact with the cornea's inner surface, thus reducing cell loss. Alcon Laboratories, Inc. developed Active Fluidics which allows to stabilize intraocular pressure and prevent IOP fluctuations as well as IOP surges during surgery. It is now further equipped with the Active Sentry handpiece which is integrated to the surgical instrument and acts as a sensor to pressure variation. It allows rapid feedback to maintain a stable AC. Our research project aims to assess the outcomes following phacoemulsification done with physiological IOP with the help of the Active Sentry handpiece compared to traditional high IOP levels.
Conditions
- Cataract
- Cataract Surgery
- Cataract Bilateral
Interventions
- DEVICE
-
Cataract surgery with Active Sentry
Surgical instrument that detects changes in intraocular pressure and allows rapid feedback to stabilize pressure during cataract surgery.
- PROCEDURE
-
Traditional cataract surgery
Cataract surgery performed with high intraocular pressures
Sponsors & Collaborators
-
Centre hospitalier de l'Université de Montréal (CHUM)
lead OTHER
Principal Investigators
-
Samir Jabbour, MD,CM,FRCSC · Centre hospitalier de l'Université de Montréal (CHUM)
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-10-31
- Primary Completion
- 2025-02-28
- Completion
- 2025-03-31
More Related Trials
-
High Intraocular Pressure After Cataract Surgery
NCT05834465 ·Status: UNKNOWN
-
Study on the Application of Adaptive Fluidics Technology in Lens Diseases Surgery
NCT07062107 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Multifunctional Cataract Surgery Assistive Instruments Used in Cataract Surgery
NCT06182605 ·Status: RECRUITING ·Phase: NA
-
Validation of an Artificial Intelligence System for Postoperative Management of Cataract Patients
NCT04138771 ·Status: UNKNOWN ·Phase: NA
-
Low Intraocular Pressure Cataract Surgery With Zeiss Quatera in Glaucoma Patients
NCT06712758 ·Status: RECRUITING
-
"Comparative Study of High-frequency Pulsed Vacuum Technology Versus Phacoemulsification for Cataract Surgery
NCT07074431 ·Status: RECRUITING ·Phase: NA
-
Validation of a Universal Cataract Intelligence Platform
NCT03623971 ·Status: COMPLETED ·Phase: NA
-
Effect of Minimizing Light Exposure Intensity on Macular Function After Cataract Surgery in Patients With Early or Intermediate AMD
NCT05988827 ·Status: COMPLETED ·Phase: NA
-
Posterior Capsulotomy in Cataract Complicated With Primary Posterior Capsule Opacification.
NCT03701139 ·Status: UNKNOWN ·Phase: NA
-
The Use of an Anterior Chamber Maintainer as a Sole Fluid Source in Micro Incision Cataract Surgery as Compared to a Standard Phacoemulsification Procedure
NCT01553760 ·Status: UNKNOWN ·Phase: NA
-
Corneal Edema After Phacoemulsification
NCT03689270 ·Status: COMPLETED
-
Feasibility of an Artificial Intelligence Phone Call After Cataract Surgery
NCT05766722 ·Status: UNKNOWN ·Phase: NA
-
Study of Multifunctional Cataract-assisted Retractor in Complicated Cataract Surgery
NCT04062084 ·Status: UNKNOWN ·Phase: NA
-
Femtosecond Laser Assisted Cataract Surgery in Intumescent Cataracts
NCT02403206 ·Status: COMPLETED ·Phase: NA
-
A Randomized Study of Intraocular Caliper-assisted Capsulotomy for Age-related Cataract Patients With Corneal Limbus Opacity
NCT04977102 ·Status: UNKNOWN ·Phase: NA
-
Optic Capture Without Anterior Vitrectomy in Pediatric Cataract Surgery
NCT05461040 ·Status: COMPLETED ·Phase: NA
-
Effect of Hyaluronidase on Intraocular Pressure
NCT03266406 ·Status: UNKNOWN ·Phase: NA
-
Outcomes of Phacoemulsification With Torsional Ultrasound
NCT01010490 ·Status: COMPLETED ·Phase: PHASE4
-
Phacoemulsification in Patients With Corneal Opacities
NCT05014269 ·Status: COMPLETED
-
Optometric Follow-up After Cataract Surgery
NCT04163926 ·Status: WITHDRAWN ·Phase: NA
-
Prospective Evaluation of Safety and Efficacy of Two Forms of Corneal Stromal Hydration
NCT00432874 ·Status: COMPLETED ·Phase: NA
-
Auditing of Poor Visual Outcomes After Un-eventual Cataract Surgery
NCT03593616 ·Status: UNKNOWN
-
Medico-economic Evaluation of Immediately Sequential Bilateral Cataract Surgery Compared With Delayed Sequential Cataract Surgery in France
NCT06737562 ·Status: RECRUITING ·Phase: NA
-
Objective Measurements of the Opacification of the Lens After Vitrectomy
NCT04566237 ·Status: COMPLETED ·Phase: NA
-
Trying a New Device for Performing Capsulorhexis in Cataract Surgery Surgery
NCT01396967 ·Status: UNKNOWN ·Phase: PHASE1