Prevention of Retained Items iN Childbirth Environment and Surgical Sites
NCT06570304 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2026-01-15
Summary
To evaluate the user confidence in the confirmation of correct counts using a novel device and to assess clinical usability of the device during surgery.
Conditions
- Retained Surgical Items
Interventions
- PROCEDURE
-
iCount Device
Designed as single use. Intended purpose - To be used to count swabs and tampons after surgery in an objective manner. This is intended to be used in patients during and just after surgery. This is a device accessory.
Sponsors & Collaborators
-
Innovate UK
collaborator OTHER_GOV -
The Royal Wolverhampton Hospitals NHS Trust
lead OTHER_GOV
Principal Investigators
-
Aditi Desai · The Royal Wolverhampton NHS Trust
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-06-30
- Primary Completion
- 2027-06-30
- Completion
- 2027-06-30
More Related Trials
-
Validity of the Vyntus CPX Metabolic Cart for Assessing Postprandial Energy Expenditure and Respiratory Exchange Ratio
NCT05100797 ·Status: UNKNOWN
-
Feasibility of a Non-invasive, Trans-abdominal, Low Cost Fetal Oximetry Probe on Pregnant Human Subjects
NCT03013842 ·Status: TERMINATED ·Phase: NA
-
Respiratory Parameters Using Advanced Airways During In-hospital Cardiac Arrest
NCT06580652 ·Status: RECRUITING
-
Fetal Life: Smart-Device Based Uterine Activity Monitoring
NCT03940365 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Efficacy of the Prototype RPC (Rapid Pulse Confirmation) Device in Detecting Return of Pulsatile Flow in Patients Preparing to Separate From CPB (Cardiopulmonary Bypass)
NCT04526249 ·Status: COMPLETED
-
Cerebral Oximeter Comparison Study
NCT01655940 ·Status: COMPLETED
-
SpO2 Accuracy Low Saturation Validation of the OxySoftN Sensor
NCT04811963 ·Status: COMPLETED
-
Care After Resuscitation
NCT02275234 ·Status: COMPLETED
-
Cricothyroidotomy Training for Physicians Outcomes Study
NCT03238950 ·Status: WITHDRAWN ·Phase: NA
-
Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
NCT05779683 ·Status: COMPLETED
-
Application of New Restraint Instruments in Safety Management of Patients After Cardiac Surgery
NCT05756101 ·Status: UNKNOWN ·Phase: NA
-
Cardiac Output Monitoring in Critically Ill Patient Undergoing Intubation
NCT03525743 ·Status: COMPLETED
-
The Impact of Real Time Ventilation Feedback on Ventilation Rate and Tidal Volume During Cardiac Arrest.
NCT06528704 ·Status: RECRUITING ·Phase: NA
-
Enhancing Operability in a Hypobaric Hypoxic Environment With a Small Oxygen Storage System
NCT03365128 ·Status: WITHDRAWN
-
Performance of Pulse Oximeter Sensors in Neonates
NCT03870373 ·Status: COMPLETED
-
Evaluation of an Investigational Wearable Vital Signs Monitoring Device in Healthy Infants
NCT05910320 ·Status: TERMINATED ·Phase: NA
-
The Cost in Oxygen of Surgical Trauma
NCT02238561 ·Status: COMPLETED
-
Monitoring of Intubation and Ventilation During Resuscitation
NCT00204217 ·Status: COMPLETED ·Phase: PHASE2
-
Hemodynamic Variations During Remote Ischemic Conditioning in Critical Ill Patients
NCT06536231 ·Status: RECRUITING ·Phase: NA
-
OM2 Motion Verification Study
NCT06415786 ·Status: COMPLETED
-
The Predictive Value of Peak Cough Flow for Endotracheal Extubation of Patients After Craniotomy
NCT04000997 ·Status: COMPLETED
-
Feasibility of End-tidal Oxygen Concentration Monitoring During Preoxygenation for Intubation in the Intensive Care Unit.
NCT05409573 ·Status: RECRUITING ·Phase: NA
-
Organ Donor Tissue Oxygen Saturation as a Predictor of Number of Organs to Transplant Per Donor
NCT01819116 ·Status: COMPLETED
-
Analysis of Volatile Organic Compounds in the Breath of Lung Transplant Rejection Patients Using Infrared Spectroscopy
NCT06309628 ·Status: TERMINATED
-
Evaluation of Pain Levels by Quantitative Pupillometry During the Placement of Deep Venous Catheters in Sedated Patients in Intensive Care Unit (PUPICAT)
NCT05962996 ·Status: RECRUITING