Results of Retrograde Titanium Elastic Nails for Fixation of Proximal Third Tibial Shaft Fractures in Children.
NCT06500325 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2024-07-15
Summary
Pediatric tibial shaft fracture is the third most common pediatric long bone fracture after fracture of femur and forearm, representing 15% of all pediatric fractures. Closed reduction and casting is the standard of care for stable and minimally displaced fracture of the tibia in pediatric age group. Treatment of pediatric fractures dramatically changed in 1982. The goals are to stabilize the fracture, control limb length, alignment, rotation, instability, promote bone healing, and minimize the morbidity and complications for the child and his/her family. Titanium elastic nails (TENs) fixation was originally meant as an ideal treatment method for femoral shaft fractures, but was gradually applied to other long bones diaphysial fractures in children, as it represents a compromise between conservative and surgical therapeutic approaches with satisfactory results and minimal complications.
Over the past 20 years, pediatric orthopedic surgeons have tried a variety of methods to treat pediatric lower limb fractures to avoid prolonged immobilization and complications. Each method has had its own complications: cast immobilization alone or following traction had resulted in limb-length discrepancy, angulations, rotational deformity, psychological and economic complications. External fixation had resulted in pin-tract infection, loss of knee range of motion, delayed union, non-union, and refracture after fixator removal. TENs work by balancing the forces between the two opposing flexible implants. To achieve this balance, the nail diameter should be 40% of the narrowest canal diameter or more. The nails should assume a double-C construct. They should have similar smooth curve and same level entry points.
Ligier et al and Flynn et al have reported that TENs can give rotational stability if good care is taken intra-operatively during nail insertion and postoperatively, especially for comminuted, spiral, and long oblique fractures.
Conditions
- Proximal Third Tibial Shaft Fractures in Children
Interventions
- PROCEDURE
-
retrograde titanium elastic nails for fixation of proximal third tibial shaft fractures in children
Two TENs were used in all cases using the double-C construct in most cases to gain three point of fixation. The starting point for nail insertion is 1.5-2.0 cm proximal to the physis of distal tibia. Both nails are then inserted through the entry holes and advanced to pass the level of the fracture site to achieve fixation. The two incisions for nail entry are closed in a layered fashion, and the wounds are well padded with gauze.
Sponsors & Collaborators
-
Sohag University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 4 Years
- Max Age
- 12 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-10-01
- Primary Completion
- 2024-10-01
- Completion
- 2024-10-01
Countries
- Egypt
Study Locations
More Related Trials
-
Optimal Index for Pediatric Distal Forearm Fractures
NCT05425758 ·Status: UNKNOWN
-
Management of Closed Diaphyseal Displaced Leg Fractures in Children and Adolescents
NCT06503718 ·Status: RECRUITING
-
Pediatric Locking Nail for the Treatment of Femoral Fractures in Children
NCT00725894 ·Status: COMPLETED
-
The Clinical and Radiological Outcomes of the Use of Titanium Elastic Nail in The Fixation of Fresh Non-comminuted Fracture Mid-shaft Clavicle
NCT05315284 ·Status: UNKNOWN ·Phase: NA
-
Ulnar Shaft Fracture Fixation by Antegrade Versus Retrograde Intramedullary k Wires in Children
NCT06781684 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Primary Dynamization Versus Standard Interlocking Intramedullary Nail in Treatment of Tibial Shaft Fractures in Adults
NCT06147219 ·Status: RECRUITING ·Phase: NA
-
Treatment of Unstable Both-Bone Midshaft Forearm Fractures in Children
NCT00314587 ·Status: UNKNOWN ·Phase: NA
-
Pediatric Femur Research Project
NCT00943332 ·Status: COMPLETED
-
Treatment of Distal Radius Buckle Fractures
NCT01762605 ·Status: TERMINATED ·Phase: NA
-
Conservative Versus Intramedullary Nailing for Pediatric Tibial Shaft Fractures
NCT05501496 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Retrograde Elastic Nailing With Pollar K-wire in Metaphyseal Diaphyseal Fracture of Distal Radius in Pediatric Patients
NCT07162142 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Plating Versus Nailing in Pediatric BB Forearm Fractures
NCT06542471 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Study of Prognostic Factors of the Distal Epiphysis of the Tibia Fracture Prognosis
NCT02723825 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Titanium Elastic Nailing Versus Hip Spica Cast in Treatment of Femoral Fractures in Children
NCT01190696 ·Status: COMPLETED ·Phase: PHASE2
-
Biobased Polyester Versus Synthetic Fiberglass Casts for Treating Stable Upper Limb Fractures in Children
NCT06102603 ·Status: COMPLETED ·Phase: NA
-
Is the Expert Nail With Poller Screws Superior to the Distal Tibial Locked Plate in the Management of Short Oblique Distal Tibial Fractures?
NCT06436365 ·Status: COMPLETED ·Phase: NA
-
Casting Versus Flexible Intramedullary Nailing in Displaced Pediatric Forearm Shaft Fractures
NCT04664517 ·Status: RECRUITING ·Phase: NA
-
Results of Gamma Nail in Trochentric Fractures of the Adults
NCT03531983 ·Status: UNKNOWN
-
Comparative Results of Conservatively and Surgically Treated Adolescents With Triplane and Juvenile Tillaux Ankle Fractures After Skeletal Maturity
NCT00541580 ·Status: TERMINATED
-
Open Tibia Fractures a Comparative Study Between Biplane External Fixator and Locked Intramedullary Nail
NCT02064595 ·Status: COMPLETED ·Phase: NA
-
Fixation of Displaced Distal Ulna Fractures in Adults by Flexible Intramedullary Nail
NCT05173181 ·Status: UNKNOWN ·Phase: NA
-
Closed Reduction of Distal Forearm Fractures by Pediatric Emergency Medicine Physicians: A Prospective Study
NCT01101607 ·Status: COMPLETED ·Phase: NA
-
Union Rate of Transverse Tibia Fracture
NCT03042533 ·Status: TERMINATED ·Phase: NA
-
Percutaneous Intramedullary K-wires Fixation of Pediatric Shaft Both Bone Forearm Fractures
NCT05744349 ·Status: UNKNOWN ·Phase: NA
-
Treatment of Talus Fractures: a Retrospective Study
NCT03639272 ·Status: COMPLETED