Comparison Between Lathe Cut Versus Cast Molding Soft Contact Lens Technique on Ocular Surface Integrity
NCT06495112 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 69
Last updated 2024-07-10
Summary
"Comparison between Lathe Cut versus Cast Molding Soft Contact Lens Technique on Ocular Surface Integrity" investigates the impact of two different manufacturing methods on the health and integrity of the ocular surface.
Conditions
- Ocular Surface Disease
Interventions
- OTHER
-
Soft contact lens with lathe cut technique Lathe
athe cut technique Lathe cutting involves shaping a solid block of lens material into the desired form using precision machinery. This method allows for customized lens designs but may result in a less smooth surface compared to cast molding. Cast molding, on the other hand, uses a liquid monomer that is cured in a mold to form the lens. This technique typically results in a smoother and more uniform lens surface.
- DIAGNOSTIC_TEST
-
Soft contact lens with cast molding technique
Participants in this arm would receive Cast molding soft contact lenses and would wear them according to the study protocol, also likely for a specified duration.The cast molding technique for soft contact lenses involves creating lenses by polymerizing a liquid monomer mixture within a mold that forms the desired lens shape. Here's a brief overview of the steps involved in the cast molding process
Sponsors & Collaborators
-
Superior University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 15 Years
- Max Age
- 35 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-11-01
- Primary Completion
- 2024-05-01
- Completion
- 2024-09-30
Countries
- Pakistan
Study Locations
More Related Trials
-
Changes Between Lenticule Extraction and Femtosecond Laser-assisted Laser in Situ Keratomileusis
NCT02550353 ·Status: COMPLETED ·Phase: NA
-
Comparison of Clinical Outcomes After Cataract Surgery With and Without Capsular Tension Ring
NCT02183831 ·Status: COMPLETED
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Comparison Between Different Investigations Used in Intraocular Lens Calculation in High Myopic Cataractous Patients
NCT04952181 ·Status: UNKNOWN ·Phase: NA
-
Objective and Subjective Evaluation of Ophthalmic Lenses With Extra Power
NCT05089240 ·Status: COMPLETED ·Phase: NA
-
Combined Capsular Tension Ring and IOL Implantation for Management of Cataracts
NCT05530473 ·Status: COMPLETED ·Phase: NA
-
Corneal Flap Thickness Planed vs Measured After LASIK by Using Tree Different Systems Cut
NCT00558324 ·Status: TERMINATED ·Phase: NA
-
Early Changes Among FLEx, LASIK and FS-LASIK
NCT02551796 ·Status: COMPLETED ·Phase: NA
-
A 2-year Longitudinal Study on the Structural and Optical Effects of Orthokeratology Treatment on Eye
NCT02643342 ·Status: COMPLETED ·Phase: NA
-
Toric Intraocular Lens (IOL) Implantation for Management of Cataracts
NCT05797298 ·Status: RECRUITING
-
Evaluation of Toric Intraocular Lens(IOL) Combined With Capsular Tension Ring(CTR) in Patients With Cataract Combined With High Myopia
NCT06571773 ·Status: ACTIVE_NOT_RECRUITING
-
Early Changes Between Lenticule Extraction and Small-Incision Lenticule Extraction
NCT02540785 ·Status: COMPLETED ·Phase: NA
-
Rotational Stability of Different Intraocular Lenses in The Capsular Bag
NCT03761745 ·Status: COMPLETED
-
Comparative Study of Two Multifocal Intraocular Lens With Different Add Power
NCT02424162 ·Status: COMPLETED ·Phase: NA
-
Quality of Vision in Implantable Collamer Lens (ICL)
NCT04982107 ·Status: COMPLETED
-
Comparison Between a Toric Monofocal and Multifocal Intraocular Lens
NCT04907318 ·Status: COMPLETED
-
Study of Subluxation Lens Biometrics and Postoperative Intraocular Lens Stability
NCT04685122 ·Status: UNKNOWN
-
Comparison of Clinical Outcomes of Small-incision Lenticule Extraction (SMILE) Between Different Cap Thickness.
NCT03584555 ·Status: COMPLETED ·Phase: NA
-
A Clinical Comparison of Two Soft Contact Lenses (C24-755)
NCT06758076 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy Study of A Viscoelastic-free Method for Implantable Collamer Lens (ICL) Implantation
NCT03059043 ·Status: RECRUITING ·Phase: NA
-
Femtolaser Assisted Keratoplasty Versus Conventional Keratoplasty
NCT03619434 ·Status: UNKNOWN ·Phase: NA
-
Rates and Risk Factors of Contact Between the OTX-TIC Intracameral Ocular Implant and Corneal Endothelium
NCT05835141 ·Status: COMPLETED
-
Visual Outcomes of Functional Intraocular Lenses in Cataracts
NCT06092164 ·Status: NOT_YET_RECRUITING
-
Long-term Comparative Analysis of Visual Outcomes With 3 Intraocular Lenses: Monofocal, Trifocal and Accommodating
NCT05041881 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of a 1-Piece Intraocular Lens
NCT01098812 ·Status: COMPLETED ·Phase: PHASE3