Performance and Safety of the Pneumoscope Device in Adults and Children
NCT06373939 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 225
Last updated 2024-07-03
Summary
Respiratory diseases are associated with high morbidity and mortality worldwide. Proper diagnosis and risk assessment of these conditions are essential for optimal management. Clinicians use three particularly useful tools to identify these conditions when assessing the patient's status: the stethoscope, the pulse oximeter, and the thermometer. The Pneumoscope is an all-in-one device including a digital stethoscope, a pulse oximeter, and a thermometer. This study aims to assess the performance and safety of the Pneumoscope in recording respiratory sounds, body temperature, non-invasive blood oxygen saturation levels and heart rate in children and adults.
Conditions
- Respiratory Diseases
- Pneumonia
- Asthma
- Cyanotic Heart Disease
Interventions
- DEVICE
-
Digital lung auscultation
Two 30-second recordings will be made using CE-marked Littmann® CORE digital stethoscopes and the Pneumoscope at two bilateral lung positions on the posterior chest wall, focusing on the lower lobes. Spectral comparison and audio quality indices will be assessed between the Pneumoscope and the Littmann® CORE digital stethoscope. Comparator: The Gold Standard Littmann® CORE picks up sounds, such as heart and lung sounds, from a patient's body. After amplification and filtering, the sounds are sent to the user through a binaural headset. The stethoscope chest piece is designed for use with adult, pediatric, and infant patients.
- DEVICE
-
Pulse oximetry measurement
Pulse oximetry and heart rate will be measured using the CE-marked Masimo Rad-G® and iHealth® Air oximeters, as well as the Pneumoscope's built-in oximeter. Agreement between the Pneumoscope's oximeter and the reference oximeters will be evaluated. Measurement will take 30 second on the right index finger. Comparators: 1. The Gold Standard Masimo Rad-G® sensor is indicated for the continuous noninvasive peripheral monitoring of arterial oxygen saturation (SpO2) and pulse rate. Its use consists in positioning the emitting window of the sensor attachment envelope on the top of the finger nail bed, while the detector is placed opposite the emitter on the other side of the same finger. 2. The Gold Standard iHealth® Air works by projecting two beams of light through a clip with a transmitter and a detector that is placed around a finger, nail side down and screen side up.
- DEVICE
-
Non invasive body temperature measurement
Comparison of body temperature measurements between the Pneumoscope's built-in thermometer and Gold Standard thermometers (Terumo® C205 and VisioFocus Pro 06480). Comparators: 1. The Gold Standard Terumo® C205 is an axillary thermometer. Its use consists in placing the probe in the armpit, then lowering the arm and holding the device firmly until the temperature is stabilised and the temperature is read and displayed on the thermometer screen. 2. The Gold Standard VisioFocus Pro 06480 is an infrared thermometer that detects the infrared radiation naturally emitted by the body and in particular from the human forehead. Its use consists in holding the thermometer close to the forehead but without direct contact with the skin. The temperature reading is then projected on the patient's forehead using a symbol system.
Sponsors & Collaborators
-
University Hospital, Geneva
collaborator OTHER -
Pediatric Clinical Research Platform
lead OTHER
Principal Investigators
-
Alain Gervaix, Prof · University Hospital, Geneva
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 1 Year
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2024-04-15
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- Switzerland
Study Locations
More Related Trials
-
Automation Oxygen Flow Titration in Spontaneously Breathing Infants
NCT03614507 ·Status: TERMINATED ·Phase: NA
-
Impact of Respiratory Pathogens in Infants
NCT01789268 ·Status: COMPLETED
-
Safety and Efficacy Study of Nitric Oxide for Inhalation on Chronic Lung Disease in Premature Babies
NCT00551642 ·Status: COMPLETED ·Phase: PHASE3
-
Pulmonary Function Using Non-invasive Forced Oscillometry
NCT03346343 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
PNEUMOSTEM for the Prevention and Treatment of Severe BPD in Premature Infants
NCT03392467 ·Status: COMPLETED ·Phase: PHASE2
-
Non Invasive Ventilation in Bronchiolitis
NCT03619499 ·Status: UNKNOWN ·Phase: NA
-
Developing and Evaluating User-Designed Data Displays
NCT02615808 ·Status: WITHDRAWN ·Phase: NA
-
Pneumacare SLP Validation in Infants and in Clinical Bronchiolitis
NCT02881632 ·Status: COMPLETED
-
Outpatient Pediatric Pulse Oximeters in Africa
NCT05914324 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Plethysmography Opto-electronic and Asthma
NCT01784146 ·Status: COMPLETED ·Phase: NA
-
Aligning Pulse Oximetry With Guidelines
NCT04178941 ·Status: COMPLETED ·Phase: NA
-
Diagnosing Respiratory Disease in Children Using Cough Sounds 2
NCT03392363 ·Status: COMPLETED
-
Remote Monitoring in Preschool Wheeze
NCT05447832 ·Status: UNKNOWN
-
mHealth for Pneumonia Prevention
NCT04493047 ·Status: COMPLETED ·Phase: NA
-
Association of Transcutaneous Pulse CO-oximetry With Inflammatory Lung Diseases
NCT02831348 ·Status: COMPLETED
-
Efficacy and Safety of Zelpultide Alfa in Preterm Neonates at High Risk of Developing Bronchopulmonary Dysplasia (BPD)
NCT06897839 ·Status: RECRUITING ·Phase: PHASE2/PHASE3
-
Evaluation of the "Breatheasy" in Pre-hospital Care
NCT04219644 ·Status: COMPLETED ·Phase: NA
-
Study of Inhaled Nitric Oxide (iNO) and Respiratory Outcomes in Late Preterm Infants
NCT01748045 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
NO Need to Ventilate: A Trial of Non-invasive Inhaled Nitric Oxide in Persistent Pulmonary Hypertension of the Newborn
NCT00139217 ·Status: COMPLETED ·Phase: NA
-
Assesment of the Effectiveness of High Frequency Oral Oscillation and Mask of PEP in Children With Pneumonia
NCT02192268 ·Status: UNKNOWN ·Phase: NA
-
Inhaled Nitric Oxide to Prevent and Treat Bronchopulmonary Dysplasia
NCT01503801 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Integrated Pulmonary Index (IPI) as a Determinate of Weaning Success and/or Failure in the Pediatric Population
NCT01795196 ·Status: WITHDRAWN
-
Overview: Use of Respiratory Support At Home in Children
NCT06692660 ·Status: NOT_YET_RECRUITING
-
A Study Pilot About the Contribution of Pleuropulmonary Echography Iin Acute Bronchiolitis Among Infants
NCT04935996 ·Status: UNKNOWN ·Phase: NA
-
Diagnosing Respiratory Disease in Children Using Cough Sounds
NCT02973282 ·Status: COMPLETED