Universal Fixed Meal Boluses Usage in Patients With Medtronic Minimed 780G Pumps
NCT06372392 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2024-04-18
Summary
Cross-over study of 20 pediatric patients (age 7-19) randomized to the group receiving universal fixed meal boluses coefficients (300/TDD for breakfast and 400/TDD other meal) or to the group with individualized coefficients for the period of 14 days with consecutive analysis of the results from Carelink Raport.
Conditions
- Type1diabetes
Interventions
- DEVICE
-
Universal meal coefficient utilization
Usage of universal fixed meal bolus coefficients for the control of postprandial hyperglycemia compared to individualized coefficients n the users of Medtronic Minimed 780G pumps
Sponsors & Collaborators
-
Estonia Research Council
collaborator UNKNOWN -
Tartu University Hospital
lead OTHER
Principal Investigators
-
Aleksandr Peet · Tartu University Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 7 Years
- Max Age
- 19 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-10-10
- Primary Completion
- 2024-06-10
- Completion
- 2024-12-01
- FDA Device
- Yes
Countries
- Estonia
Study Locations
More Related Trials
-
The Impact of Hybrid Closed-loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs
NCT04414280 ·Status: ACTIVE_NOT_RECRUITING
-
The Efficacy of MDI Treatment With an Optimization Algorithm Adjusting Basal-Bolus Parameters in Children and Adolescents With Type 1 Diabetes at a Diabetes Camp
NCT03764280 ·Status: COMPLETED ·Phase: NA
-
Optimizing Metabolic Control in Type 1 Diabetes - The Automatic Bolus Calculator Flash Study
NCT03682237 ·Status: COMPLETED ·Phase: NA
-
Safety Evaluation of MiniMed™ 780G System With DS5 CGM in Children
NCT06604871 ·Status: COMPLETED ·Phase: NA
-
Study of Insulin Therapy Augmented by Real Time Sensor IN Type 1 Children and Adolescents (START-IN!)
NCT00949221 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Hybrid Closed-Loop Control With Smart Prandial Insulin Dosing in Type 1 Diabetes
NCT04878120 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Management Systems in Patients With Type 1 Diabetes (Pediatric SmartHome)
NCT03815487 ·Status: COMPLETED ·Phase: NA
-
Glycaemic Load and Pre-meal Insulin Doses in Type 1 Diabetes Patients
NCT01978704 ·Status: COMPLETED ·Phase: NA
-
QUality of Control and slEep in Children With diabeteS, Using New Technology
NCT03103867 ·Status: COMPLETED ·Phase: NA
-
The Impact of Daily Carbohydrate Intake on Glycemic Control in Children and Adolescents With Type 1 Diabetes Using an Advanced Hybrid Closed-loop System
NCT05866900 ·Status: UNKNOWN
-
Use of an Automated Insulin Delivery System Compared to Sensor Augmented Pump at Patients With Type 1 Diabetes (T1D)
NCT02636491 ·Status: COMPLETED ·Phase: NA
-
The MiniMed™ 780G Glycemic Control and Quality of Life Study for the Treatment of Pediatric and Adult Subjects With Type 1 Diabetes in France.
NCT04308291 ·Status: COMPLETED
-
Prevention of Hypoglycaemia With Predictive Insulin Suspend Using Sensor Augmented Insulin Pump in Children
NCT02179281 ·Status: COMPLETED ·Phase: NA
-
Glycemic Excursions in Patients With Type 1 Diabetes Mellitus Using Closed-loop Systems
NCT06382350 ·Status: RECRUITING
-
OpT2mise Glucose Control in Type 2 Diabetes Mellitus (DM) With Insulin Pump Therapy
NCT01182493 ·Status: COMPLETED ·Phase: NA
-
Assessment of Two Insulin Pump Insulin Delivery Systems in Type 1 Diabetes.
NCT04073576 ·Status: UNKNOWN ·Phase: NA
-
Outpatient Reduction of Nocturnal Hypoglycemia by Using Predictive Algorithms and Pump Suspension in Children
NCT01823341 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-Loop Insulin Delivery in Children Less Than 7 Years of Age
NCT01421225 ·Status: COMPLETED ·Phase: NA
-
Study of MiniMed™ 640G Insulin Pump With SmartGuard™ in Prevention of Low Glucose Events in Adults With Type 1 Diabetes
NCT02733991 ·Status: COMPLETED ·Phase: NA
-
Effect of Advanced Hybrid Closed Loop System, MiniMed 780G in Newly Diagnosed Children and Adolescents With Type 1 Diabetes on Glycemic Control and Patient Reported Outcomes Compared to Standard Insulin Therapy Historical Data (AHCL in New Onset T1D Children Study)
NCT06919029 ·Status: RECRUITING
-
Fake Carbs Practice With AID System - MiniMed 780G in Children and Adolescents With T1D.
NCT07179471 ·Status: RECRUITING
-
24/7 Closed-loop in Older Subjects With Type 1 Diabetes
NCT04025762 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Physician-based Decision Support
NCT03443713 ·Status: COMPLETED ·Phase: NA
-
Simple Meal Management Using Automated Insulin Delivery System
NCT06130215 ·Status: RECRUITING ·Phase: NA
-
Efficacy of Coordinated Insulin Boluses in Type 1 Diabetic Patients
NCT02229097 ·Status: COMPLETED ·Phase: PHASE4