A Study of the THERMOCOOL SMARTTOUCH Surround Flow (SF) Catheter With the TRUPULSE Generator for Treatment of Drug Refractory Symptomatic PAF
NCT06144632 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 237
Last updated 2026-01-16
Summary
The purpose of this study is to demonstrate safety and effectiveness of the Biosense Webster (BWI) ablation system (THERMOCOOL SMARTTOUCH surround flow \[STSF\] catheter and TRUPULSE generator) when used for isolation of the atrial pulmonary veins (PVs) in treatment of participants with paroxysmal atrial fibrillation (PAF), an irregular heart rate that causing abnormal blood flow.
Conditions
- Drug Refractory Paroxysmal Atrial Fibrillation
Interventions
- DEVICE
-
THERMOCOOL STSF Bi- Directional Navigation Catheter
THERMOCOOL STSF will be used in conjunction with TRUPULSE Generator to give pulsed field (PF) ablation or radiofrequency (RF) ablation.
- DEVICE
-
TRUPULSE Generator
TRUPULSE Generator will be used to deliver PF/RF ablation.
Sponsors & Collaborators
-
Biosense Webster, Inc.
lead INDUSTRY
Principal Investigators
-
Biosense Webster Inc. Clinical Trial · Biosense Webster, Inc.
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-12-07
- Primary Completion
- 2025-10-30
- Completion
- 2025-10-30
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Safety and Effectiveness of STSF Catheter Evaluated for Treating Symptomatic Persistent Atrial Fibrillation (PsAF)
NCT02817776 ·Status: COMPLETED ·Phase: NA
-
A Study for Treatment of Paroxysmal Atrial Fibrillation (PAF) by Pulsed Field Ablation (PFA) System With Irreversible Electroporation (IRE)
NCT04524364 ·Status: COMPLETED ·Phase: NA
-
A Study For Treatment of Paroxysmal Atrial Fibrillation (PAF) With the OMNYPULSE Catheter and the TRUPULSE Generator
NCT05971693 ·Status: COMPLETED ·Phase: NA
-
Exploratory Safety and Effectiveness Evaluation of Pulsed Field Ablation (PFA) by Balloon Catheter With TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)
NCT06495216 ·Status: WITHDRAWN ·Phase: NA
-
A Study Assessing Long-Term Safety and Effectiveness in Treatment Management of Atrial Fibrillation With VARIPULSE Catheter System
NCT07227532 ·Status: RECRUITING ·Phase: NA
-
THERMOCOOL SMARTTOUCH®SF Catheters With Ablation Index Study
NCT03963349 ·Status: ACTIVE_NOT_RECRUITING
-
A Study of the TactiFlex SE Catheter and Volt PFA Generator in Subjects With PAF:
NCT06676072 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
NAVISTAR® THERMOCOOL® Catheter for the Radiofrequency Ablation of Symptomatic Paroxysmal Atrial Fibrillation- Treatment Use Study
NCT00721149 ·Status: TERMINATED ·Phase: PHASE3
-
NAVISTAR® THERMOCOOL® Catheter for the Radiofrequency Ablation of Symptomatic Paroxysmal Atrial Fibrillation
NCT00116428 ·Status: COMPLETED ·Phase: PHASE3
-
A Study of Assessment on Safety and Effectiveness of BWI Pulsed Field Ablation With OMNYPULSE Catheter for the Treatment of Paroxysmal Atrial Fibrillation (PAF)
NCT06455098 ·Status: RECRUITING ·Phase: NA
-
Pulmonary Vein Reconnection Following Ablation Index-guided Ablation: a Success Evaluation
NCT02628730 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study for Workflow and Performance Evaluation of the THERMOCOOL SMARTTOUCH® SF-5D System for Treating Symptomatic Paroxysmal AF (QDOT-Micro)
NCT02944968 ·Status: COMPLETED ·Phase: NA
-
Real-world Experience of Catheter Ablation for the Treatment of Paroxysmal and Persistent Atrial Fibrillation
NCT04088071 ·Status: RECRUITING
-
NAVISTAR® THERMOCOOL® Catheter Post Approval Registry
NCT00964392 ·Status: COMPLETED ·Phase: PHASE4
-
Atrial Pressure Electrophysiology Pilot Study
NCT01845974 ·Status: TERMINATED ·Phase: NA
-
Atrial Fibrillation Progression Trial
NCT01570361 ·Status: TERMINATED ·Phase: PHASE4
-
NAVISTAR® THERMOCOOL® SF Catheter: Observational Study
NCT01585961 ·Status: COMPLETED
-
A Study of Multi-electrode Circular Irreversible Electroporation (IRE) Catheter and Multi-Channel IRE Generator in Paroxysmal Atrial Fibrillation (AF)
NCT05552963 ·Status: COMPLETED ·Phase: NA
-
nMARQ™ Pulmonary Vein Isolation System for the Treatment of Paroxysmal Atrial Fibrillation
NCT01824394 ·Status: TERMINATED ·Phase: PHASE3
-
Clinical Evaluation of the Blazer Open-Irrigated Ablation Catheter for the Treatment of Paroxysmal Atrial Fibrillation
NCT01687166 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of Open Irrigated Ablation Catheters With High Resolution Mapping to Treat Paroxysmal Atrial Fibrillation
NCT03729830 ·Status: COMPLETED
-
Safety and Effectiveness of Pulmonary Vein isOLation And posterioR Wall Ablation wIth pulSed Field Energy in Patients With Paroxysmal and Persistent AF
NCT06099730 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Safety and Efficacy Study of the First Domestically Produced FireMagic™ PreciSense™ 3D Microelectrode Ablation Catheter Therapy for Rapid Arrhythmia With Tissue Temperature Measurement Function
NCT07032948 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Ablation Index and VISITAG™ (ABI-173)
NCT03062046 ·Status: COMPLETED ·Phase: NA
-
Pulsed ElectRic FiEld Versus Cryoballoon for PAF
NCT07100834 ·Status: COMPLETED ·Phase: NA