Intrapartum Non-invasive Electrophysiological Monitoring

NCT06135961 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 3471

Last updated 2023-12-15

No results posted yet for this study

Summary

Conventional cardiotocography (CTG) has been used extensively for more than 50 years to monitor the fetal condition during labour, but since the rate of operative deliveries keeps rising, its ability to improve neonatal outcomes is unsatisfactory. A transabdominal non-invasive and wireless alternative which overcomes the shortcomings of conventional methods is electrophysiological CTG (eCTG) monitoring. In eCTG the fetal heart rate (FHR) is measured by fetal electrocardiography (NI-fECG) and uterine activity (UA) by electrohysterography (EHG). Both NI-fECG and EHG have been proven more accurate and reliable than conventional non-invasive methods and are less affected by maternal body mass index (BMI).

This study aims to evaluate the mode of delivery, maternal and perinatal outcomes, costs and patient and healthcare professionals perspectives on eCTG monitoring versus the conventional CTG during labour at term with a singleton fetus in cephalic position.

The eCTG provides a more accurate assessment of the fetus and the UA, compared to the conventional CTG. This allows for optimization of the contraction pattern during high-risk deliveries. We hypothesize that this will reduce the number of operative interventions and improves perinatal outcome. There are three reasons why an improvement in the contraction pattern by the eCTG can influence our outcomes:

1. EHG can detect excessive UA more accurately. Increased UA is a major risk for fetal distress. In this case, stimulation with oxytocin should be reduced or stopped. More adequate interpretation of FHR, reduced tachysystole and reduced hypertonia is expected to result in fewer instrumented vaginal deliveries and a reduction of caesarean sections due to fetal distress.
2. EHG can demonstrate unorganized UA that needs to be corrected with a higher dose of oxytocin to enhance contraction frequency and efficiency. This can result in a less exhausted uterine muscle, shorter time to delivery, less vacuum deliveries and caesarean sections due to failure of progress. A shorter time to delivery will also result in a reduction of infections and blood loss.
3. Accurate registration of the relation between the contraction and decelerations of FHR, is expected to result in more reliable assessment of the fetal condition. This can result in fewer unnecessary operative deliveries and less unpredictable poor perinatal outcomes.

Conditions

  • Fetal Monitoring
  • Non-invasive
  • Cardiotocography
  • Electrocardiography
  • Caesarean Section

Interventions

DEVICE

eCTG monitoring with the NFMS

Device: Nemo Fetal Monitoring System (Nemo Healthcare B.V., Veldhoven, the Netherlands)

Sponsors & Collaborators

  • ZonMw: The Netherlands Organisation for Health Research and Development

    collaborator OTHER
  • Maxima Medical Center

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
FEMALE
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2023-11-20
Primary Completion
2025-11-20
Completion
2026-02-15

Countries

  • Netherlands

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06135961 on ClinicalTrials.gov