Intrapartum Non-invasive Electrophysiological Monitoring
NCT06135961 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 3471
Last updated 2023-12-15
Summary
Conventional cardiotocography (CTG) has been used extensively for more than 50 years to monitor the fetal condition during labour, but since the rate of operative deliveries keeps rising, its ability to improve neonatal outcomes is unsatisfactory. A transabdominal non-invasive and wireless alternative which overcomes the shortcomings of conventional methods is electrophysiological CTG (eCTG) monitoring. In eCTG the fetal heart rate (FHR) is measured by fetal electrocardiography (NI-fECG) and uterine activity (UA) by electrohysterography (EHG). Both NI-fECG and EHG have been proven more accurate and reliable than conventional non-invasive methods and are less affected by maternal body mass index (BMI).
This study aims to evaluate the mode of delivery, maternal and perinatal outcomes, costs and patient and healthcare professionals perspectives on eCTG monitoring versus the conventional CTG during labour at term with a singleton fetus in cephalic position.
The eCTG provides a more accurate assessment of the fetus and the UA, compared to the conventional CTG. This allows for optimization of the contraction pattern during high-risk deliveries. We hypothesize that this will reduce the number of operative interventions and improves perinatal outcome. There are three reasons why an improvement in the contraction pattern by the eCTG can influence our outcomes:
1. EHG can detect excessive UA more accurately. Increased UA is a major risk for fetal distress. In this case, stimulation with oxytocin should be reduced or stopped. More adequate interpretation of FHR, reduced tachysystole and reduced hypertonia is expected to result in fewer instrumented vaginal deliveries and a reduction of caesarean sections due to fetal distress.
2. EHG can demonstrate unorganized UA that needs to be corrected with a higher dose of oxytocin to enhance contraction frequency and efficiency. This can result in a less exhausted uterine muscle, shorter time to delivery, less vacuum deliveries and caesarean sections due to failure of progress. A shorter time to delivery will also result in a reduction of infections and blood loss.
3. Accurate registration of the relation between the contraction and decelerations of FHR, is expected to result in more reliable assessment of the fetal condition. This can result in fewer unnecessary operative deliveries and less unpredictable poor perinatal outcomes.
Conditions
- Fetal Monitoring
- Non-invasive
- Cardiotocography
- Electrocardiography
- Caesarean Section
Interventions
- DEVICE
-
eCTG monitoring with the NFMS
Device: Nemo Fetal Monitoring System (Nemo Healthcare B.V., Veldhoven, the Netherlands)
Sponsors & Collaborators
-
ZonMw: The Netherlands Organisation for Health Research and Development
collaborator OTHER -
Maxima Medical Center
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-11-20
- Primary Completion
- 2025-11-20
- Completion
- 2026-02-15
Countries
- Netherlands
Study Locations
More Related Trials
-
Physiological Effects of Deferred Cord Clamping
NCT01864421 ·Status: TERMINATED
-
IMPACTS OF BRAXTON-HICKS CONTRACTIONS ON COMPUTERISED CARDIOTOCOGRAPHY PARAMETERS: A POTENTIAL LINK.
NCT04417296 ·Status: COMPLETED
-
Improving Ultrasound Based Prediction of Delivery Mode
NCT04635410 ·Status: UNKNOWN
-
Mindfulness-based Intervention Prior to External Cephalic Version
NCT06768060 ·Status: RECRUITING ·Phase: NA
-
Patient Satisfaction During Physiological Water or Land Birth: a Prospective Study in an French Tertiary Maternity Unit.
NCT06441370 ·Status: RECRUITING
-
The Proactive Support of Labor Study
NCT03056313 ·Status: COMPLETED ·Phase: NA
-
Comparing Two Methods of Contractions Monitoring for Clinical Decision Making Regarding Treatment Among Pregnant Women With Preterm Contractions.
NCT02875418 ·Status: UNKNOWN ·Phase: PHASE3
-
Lower Limb Compression Prevents Hypotension After Epidural in Labor
NCT04750486 ·Status: COMPLETED ·Phase: NA
-
Electrical Inhibition (EI): A Preliminary Study To Inhibit Preterm Labor And Preterm Birth
NCT02569216 ·Status: WITHDRAWN ·Phase: PHASE1
-
Continuous Fetal Monitoring During Vacuum Delivery
NCT00956826 ·Status: UNKNOWN ·Phase: EARLY_PHASE1
-
Electrical Inhibition of Human Preterm Contractions
NCT02983240 ·Status: SUSPENDED ·Phase: NA
-
Noninvasive Monitoring of Uterine Activity and Fetal Heart Rate
NCT05782296 ·Status: COMPLETED
-
The Effect of Combined Spinal-Epidural Analgesia on the Success of External Cephalic Version (ECV) for Breech Position
NCT00565383 ·Status: COMPLETED ·Phase: NA
-
Electronic Partograph: A Way of Improving Partograph Use During Labour Monitoring Process in Selected District Hospitals in Bangladesh
NCT03509103 ·Status: COMPLETED ·Phase: NA
-
PROPENSITY-ID: Sonographic and Clinical Assessment of Head Position Prior to Instrumental Delivery and Labour Outcomes
NCT05557097 ·Status: UNKNOWN
-
Intrapartum Ultrasound in Labor: Sonography Only, Few Internal Examinations
NCT06261710 ·Status: RECRUITING ·Phase: NA
-
Labour Analgesia and Movement in Babies
NCT01280084 ·Status: COMPLETED
-
Study to Determine if Monitoring of Labor Shortens the Time to Delivery
NCT01005667 ·Status: WITHDRAWN ·Phase: NA
-
Pulse Pressure Variability With Position Before EPIdural Analgesia
NCT03126136 ·Status: COMPLETED ·Phase: NA
-
Trial of Underwater Birth
NCT07313319 ·Status: RECRUITING ·Phase: NA
-
Induction of Labor in Breech Presentation
NCT07071662 ·Status: COMPLETED
-
Patient Centered Simulation For Labor and Delivery
NCT03654079 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Relationship Between Delivery Route and Fetal Complications With Doppler Indices and CPR Parameters
NCT04158609 ·Status: COMPLETED
-
Pulsatile Pressure Waveform to Confirm Correct Placement of the Epidural in Laboring Patients
NCT02395796 ·Status: TERMINATED ·Phase: NA
-
Assessment of Pelvis Diameters as a Predictor for the Mode of Delivery ,Using Non-invasive, Ultrasound Based Measurements
NCT01093144 ·Status: UNKNOWN ·Phase: NA