Dextrose Concentration Decline Rate in Vivo
NCT06128122 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1
Last updated 2024-01-09
Summary
Measuring the speed of decrease in dextrose concentration to help design more accurate in vitro studies
Conditions
- Dextrose Concentration
Interventions
- PROCEDURE
-
Intrarticular and subcutaneous dextrose injection with timed measurement of dextrose levels
Step one: 30 mL of 12.5%/0.1% lidocaine will be injected into the knee using an inferomedial approach. Using ultrasound guidance, a 20-gauge 2-inch I.V. catheter will be placed in the suprapatellar pouch, by which samples of synovial fluid from the pouch will be withdrawn and analyzed for glucose level. Step two: 3 mL of D5W will be injected into a marked spot on the back of the upper arm. A sensor/transmitter (Dexcom G7 Dexcom) is placed at the site of injection. The sensor/transmitter will begin providing dextrose levels at 5 minute intervals beginning one-half hour after placement of the sensor/transmitter, transmitted to a paired smart phone.
Sponsors & Collaborators
-
Dr. Dean Reeves Clinic
lead OTHER
Principal Investigators
-
Kenneth D Reeves, M.D. · Dr. Dean Reeves Clinic
Study Design
- Allocation
- NA
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 69 Years
- Max Age
- 69 Years
- Sex
- MALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-12-19
- Primary Completion
- 2024-01-04
- Completion
- 2024-01-08
Countries
- United States
Study Locations
More Related Trials
-
Pharmacokinetics/Dynamics of Basal (Continuous) Insulin Infusion Administered Either Intradermally or Subcutaneously
NCT01061216 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
A Research Study of a New Medicine NNC0363-1063 in Participants With Type 1 Diabetes
NCT07305805 ·Status: RECRUITING ·Phase: PHASE1
-
The Use of Mini-dose Glucagon to Prevent Exercise-induced Hypoglycemia in Type 1 Diabetes
NCT02660242 ·Status: COMPLETED ·Phase: PHASE2
-
A Trial Investigating the Safety, Tolerability, and Distribution and Activity in the Body of NNC0148-0000-0287 Injected Under the Skin in Healthy Subjects and in Subjects With Type 1 Diabetes
NCT01730014 ·Status: COMPLETED ·Phase: PHASE1
-
Lisofylline as Continuous Subcutaneous and Intravenous Administration in Subjects With Type 1 Diabetes Mellitus
NCT01603121 ·Status: TERMINATED ·Phase: PHASE1/PHASE2
-
Insulin-based Strategies to Prevent Hypoglycemia During Exercise
NCT03349489 ·Status: UNKNOWN ·Phase: NA
-
Obtain a Good Blood Glucose Control With the Paradigm Real Time System
NCT00441129 ·Status: COMPLETED ·Phase: NA
-
Flexible Insulin Therapy Untethered Insulin Regimen in Avidly Exercising Patients With Type 1 Diabetes: FIT Untethered
NCT03838783 ·Status: UNKNOWN ·Phase: PHASE4
-
Intra-Arterial Microdosing: Proof-of-Concept in Humans
NCT02304211 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Caffeine Ingestion to Counter the Exercise-mediated Fall in Glycaemia in Type 1 Diabetes
NCT04671043 ·Status: COMPLETED ·Phase: NA
-
Carbohydrate and Insulin Requirements During Prolonged Fasted Exercise
NCT04383015 ·Status: COMPLETED ·Phase: NA
-
A Three-part Study to Evaluate the Safety, Pharmacokinetics and Pharmacodynamics of MK-2640 in Healthy Participants (Part I) and Participants With Type 1 Diabetes Mellitus (Parts II and III) (MK-2640-001)
NCT02269735 ·Status: COMPLETED ·Phase: PHASE1
-
A Trial Investigating the Relationship Between Pharmacodynamic and Interstitial Concentration for Insulin Detemir and Human Insulin
NCT02162407 ·Status: COMPLETED ·Phase: PHASE1
-
Transitioning Open Heart Surgery Patients From Insulin Infusions to Detemir
NCT00717288 ·Status: COMPLETED ·Phase: PHASE4
-
Feasibility Study of the Effect of Intra-Dermal Insulin Injection on Blood Glucose Levels After Eating
NCT00553488 ·Status: COMPLETED ·Phase: PHASE2
-
The Role of Proper Insulin Injection Technique in the Treatment of Diabetes Mellitus
NCT04120974 ·Status: COMPLETED ·Phase: NA
-
Multi-day (3) In-patient Evaluation of Intradermal Versus Subcutaneous Basal and Bolus Insulin Infusion
NCT01557907 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Insulin Detemir Action in Cerebro
NCT00626080 ·Status: COMPLETED ·Phase: NA
-
A Study of a Novel Insulin Lispro Formulation in Participants With Type 1 Diabetes Mellitus Using Insulin Pumps
NCT02623478 ·Status: WITHDRAWN ·Phase: PHASE1
-
Pharmacokinetic Comparison of Intradermal Versus Sub-cutaneous Insulin and Glucagon Delivery in Type 1 Diabetes
NCT01684956 ·Status: UNKNOWN ·Phase: PHASE2
-
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
NCT06181721 ·Status: COMPLETED ·Phase: NA
-
A Trial Investigating the Safety, Tolerability, Pharmacokinetics and Pharmacodynamics of Subcutaneous NNC0143-0406 A 0.6 mmol/L in Subjects With Type 1 Diabetes
NCT02612844 ·Status: COMPLETED ·Phase: PHASE1
-
Comparison of Premixed Insulin With Basal-plus Insulin in Type 2 Diabetes Patients
NCT02219750 ·Status: COMPLETED ·Phase: PHASE4
-
Pharmacokinetics (PK)/ Pharmacodynamics (PD) of an Extended Wear Infusion Set for Continuous Subcutaneous Insulin Infusion (CSII) in Type 1 Diabetes Mellitus (T1DM) Patients ("PEXIS")
NCT04398030 ·Status: COMPLETED ·Phase: NA
-
Glucagon Infusion in T1D Patients With Recurrent Severe Hypoglycemia: Effects on Counter-Regulatory Responses
NCT03490942 ·Status: TERMINATED ·Phase: PHASE2