Assessment of Coated Orthodontic Miniscrews With Chlorhexidine Hexametaphosphate Antimicrobial Nanoparticles
NCT06124235 · Status: COMPLETED · Phase: PHASE3 · Type: INTERVENTIONAL · Enrollment: 39
Last updated 2023-12-29
Summary
Aim To compare between orthodontic miniscrews coated and uncoated with CHX- HMP NP nanoparticles.
Conditions
- Orthodontic Appliance Complication
Interventions
- COMBINATION_PRODUCT
-
Coated Orthodontic Miniscrews with Chlorhexidine Hexametaphosphate Nanoparticles
insertion: 1. According to the random number generated, the corresponding envelop for left and right side by chosen. 2. The patient will be asked to brush his/her teeth. 3. The patient will rinse his/her mouth with chlorhexidine mouth rinse (0.12%) just before surgery being at least half an hour after brushing. The miniscrews used conical shaped, self-drilling, 1.6 mm in diameter, 8mm in length made of Ti. 1. The site of insertion determined from the x-ray by using stent that will be fabricated for accurate site for OMS. 2. Infiltration LA will be administered. Approximately 0.45 mL ,injected into the alveolar mucosa above the OMS placement site, in order to provides an acceptable anesthesia, while still allowing the patient feedback in case the OMS contacting the periodontal ligament (PDL). 3. OMS will be placed manually by screw driver on buccally at an angle 90 degrees and then adjusted to the appropriate angle. 4. x-ray will be taken to confirm OMS position.
- COMBINATION_PRODUCT
-
Uncoated Miniscrew with Chlorhexidine Hexametaphosphate Nanoparticles
Non-coated orthodontic miniscrews
Sponsors & Collaborators
-
University of Baghdad
lead OTHER
Principal Investigators
-
Akram F. Alhuwaizi, Prof. · [email protected]
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 13 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-02-10
- Primary Completion
- 2023-11-12
- Completion
- 2023-12-20
Countries
- Iraq
Study Locations
More Related Trials
-
The Efficacy of Different Adjunctive Plaque Control Modalities in Orthodontic Patients
NCT05889975 ·Status: COMPLETED ·Phase: PHASE3
-
Strontium-Hydroxyapatite Coated Mini-Screws: Antibacterial Effect and Stability
NCT07105969 ·Status: RECRUITING ·Phase: NA
-
Clinical Performance of the I-arch System During the Initial Stage of Orthodontic Treatment
NCT07264127 ·Status: RECRUITING ·Phase: NA
-
A Clinical Comparison of the Effectiveness of Two Types of Orthodontic Aligning Archwire Materials
NCT04090931 ·Status: COMPLETED ·Phase: NA
-
The Mini-Screw as Orthodontic Anchoring: Survival, Clinical Efficiency and Experience of the Patient
NCT00137137 ·Status: COMPLETED ·Phase: NA
-
Distalization by Miniscrew
NCT02427282 ·Status: COMPLETED ·Phase: PHASE1
-
The Effectiveness of Biomimetic Materials in Preventing Enamel Demineralization During Fixed Orthodontic Treatment
NCT05940701 ·Status: UNKNOWN ·Phase: NA
-
Bracket Failure With a Novel Etchant Paste. A Randomized Clinical Trial
NCT05766033 ·Status: UNKNOWN ·Phase: NA
-
Addition of Silver Nanoparticles to a Orthodontic Primer in Preventing Enamel Demineralization Adjacent Brackets
NCT02400957 ·Status: UNKNOWN ·Phase: PHASE3
-
Biological Effects of Commercial Orthodontic Miniscrews
NCT03460132 ·Status: UNKNOWN ·Phase: NA
-
Accuracy, Stability and Safety of Orthodontic Mini-implant Template in the Infrazygomatic Crest Zone
NCT06786221 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Microplastic Exposure From Clear Aligner Wear (MPE)
NCT06934603 ·Status: RECRUITING
-
Success Rate of the Miniscrews in the Mandibular Buccal Shelf
NCT05280678 ·Status: COMPLETED ·Phase: NA
-
Halitosis During Active Orthodontic Treatment
NCT03901625 ·Status: UNKNOWN ·Phase: NA
-
"Augmented Reality-Assisted Miniscrew Placement in Orthodontics: A Clinical Trial"
NCT07112417 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison Between Effectiveness of Different Esthetic Orthodontic Appliances
NCT06803433 ·Status: COMPLETED ·Phase: NA
-
"Three Dimensional Assessment of Maxillary Molars Following Distalization Using Two Different Approaches"
NCT06240923 ·Status: COMPLETED ·Phase: NA
-
3D Printed vs. Milled Occlusal Splints in Dentistry
NCT07236294 ·Status: NOT_YET_RECRUITING
-
Evaluation of the Periodontal Status After the Treatment of Palatally Impacted Canines Using Acceleration Procedures
NCT05644678 ·Status: COMPLETED ·Phase: NA
-
Effect of Shock Waves on Tooth Movement and Miniscrew Stability
NCT01695928 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Flash-free Brackets and Dental Plaque
NCT03187483 ·Status: COMPLETED ·Phase: NA
-
Tooth Discoloration and Chairside Handling Time (Bonding-Debonding) in Flowable Versus Packable Composites for Clear Aligner Bonded Attachments: A Randomized Clinical Trial
NCT07234149 ·Status: RECRUITING ·Phase: NA
-
Evaluation Of Anchorage Control Using Arch Wire Stopper Versus Mini-Screws
NCT06416904 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Effectiveness of Three Teaching Methods in Oral Hygiene in Adolescent Orthodontic Patients
NCT04444154 ·Status: UNKNOWN ·Phase: NA
-
Mandibular First Molar Distalization
NCT04229797 ·Status: NOT_YET_RECRUITING ·Phase: NA