Evaluating the Addition of Hemodiafiltration to EVLP - Impact on the Regeneration of Marginal Donor Lungs
NCT06082401 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2025-05-14
Summary
The primary objective of the study is the evaluation of the effect of hemodiafiltration during ex vivo lung perfusion in marginal donor lungs, and its feasibility. The hypothesis of this study is that this therapy could stabilize perfusate electrolyte composition, remove toxins and waste products, normalize pH levels and prevent edema formation, thereby reconditioning marginal donor lungs for transplantation.
The proposed pilot study addresses the unmet clinical needs in several aspects: a) for the first time a homeostatic device will be introduced in EVLP to reach stable perfusate composition; b) the proposed modification of the standard EVLP could lead to longer perfusion times, making elective transplantation possible and setting the base for possible ex vivo lung treatments; c) the ultimate effect of the proposed study is to increase organ availability through reconditioning of marginal donor lungs.
Conditions
- Lung Diseases
Interventions
- DEVICE
-
hemodiafiltration (HDF)
Hemodiafiltration (HDF) is a variation of conventional HD. By the addition of a substitution solution, convection forces are significantly increased. This substitution solution is added to the blood and is completely removed again in the dialyzer. This increases the negative pressure on the dialysate side and the removal of toxins through convection. The substitution solution can be added in a pre-dilution (before the dialyzer) or post-dilution (after the dialyzer) manner. Pre-dilution is associated with longer run times, less filter clotting, but is also less effective in removing toxins. Post-dilution offers a better toxin clearance capacity, but is associated with an increased risk of filter clotting. Several studies have shown that HDF provides higher clearance rates for both small and middle molecule solutes. Moreover, effective cytokine removal has been shown in HDF both in acute and chronic renal disease patients.
- DEVICE
-
Ex vivo lung perfusion (EVLP)
Lung transplantation has become a standard treatment for patients suffering from end-stage lung diseases. One of the major obstacles in the modern transplant era is the fact that the need for organs by far exceeds availability. This leads to growing waiting lists with mortality rates ranging between 10-30%. On the other hand, up to 80% of offered lungs from brain dead donors are rejected because they do not meet predefined donor selection criteria. Recently, ex vivo lung perfusion (EVLP) has become available as a tool to expand the donor pool. Based on experimental work by Stig Steen, the Toronto lung transplant group developed an EVLP system with the purpose to evaluate lungs with uncertain quality. Consequently, Aigner et al. have expanded the indications for EVLP by showing that primarily unacceptable donor lungs can be reconditioned and then become suitable for transplantation. This concept of organ repair by EVLP has recently been highlighted by a number of publications.
Sponsors & Collaborators
-
XVIVO Perfusion
collaborator INDUSTRY -
Medical University of Vienna
lead OTHER
Principal Investigators
-
Alberto Benazzo, MD · Medical University of Vienna
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-09-01
- Primary Completion
- 2025-12-31
- Completion
- 2025-12-31
Countries
- Austria
Study Locations
More Related Trials
-
Flow-flow ECCO2-R and 4 ml/kg Tidal Volume vs. 6 ml/kg Tidal Volume to Enhance Protection From VILI in Acute Lung Injury
NCT01522599 ·Status: TERMINATED ·Phase: PHASE3
-
Enhanced Lung Protective Ventilation With ECCO2R During ARDS
NCT03525691 ·Status: TERMINATED ·Phase: NA
-
Sustained Effects of Thoracocentesis in Mechanically Ventilated Patients
NCT00915161 ·Status: COMPLETED
-
Electrical Activity of the Diaphragm and Respiratory Mechanics During NAVA
NCT05689476 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Prolonged Apnea Supported by High Frequency Non-invasive Ventilation.
NCT02712190 ·Status: UNKNOWN ·Phase: NA
-
Early Versus Late ECMO Therapy in COVID-19 Induced ARDS (ECMO-VID)
NCT04341285 ·Status: WITHDRAWN ·Phase: NA
-
Changes in Refractory Acute Respiratory Distress Syndrome (ARDS) Patients Under High Frequency Oscillation-ventilation
NCT01167621 ·Status: COMPLETED
-
Ex-Vivo Lung Perfusion to Increase the Number of Organs for Transplantation
NCT01967953 ·Status: COMPLETED ·Phase: PHASE1
-
Ventilation and Perfusion in the Respiratory System
NCT05081895 ·Status: COMPLETED
-
NIV Versus HFO for Acute Exacerbations of Interstitial Lung Diseases
NCT06182956 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Veno-venous Extracorporeal CO2 Removal in ARDS-patients to Treat Respiratory Acidosis
NCT01911533 ·Status: COMPLETED ·Phase: NA
-
Assessment of Hemodynamic Changes During Weaning From Mechanical Ventilation With Flo-Trac Vigileo (TM) Monitor.
NCT00631683 ·Status: WITHDRAWN
-
Phrenic Nerve Stimulation-Induced Lung ReAeration Trial
NCT04844892 ·Status: COMPLETED ·Phase: NA
-
The Effect of Lt to Rt Shunt Using Veno-veno-arterial Extracorporeal Membrane Oxygenation (ECMO) on Coronary Oxygenation in Lung Transplantation Patients
NCT02859194 ·Status: COMPLETED ·Phase: NA
-
High Frequency Oscillatory Ventilation for Acute Respiratory Distress Syndrome (ARDS)
NCT01478802 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Strategies for Optimal Lung Ventilation in ECMO for ARDS: The SOLVE ARDS Study
NCT01990456 ·Status: UNKNOWN ·Phase: NA
-
Extracorporeal Lung Assist to Avoid Intubation in Patients Failing Noninvasive Ventilation for Hypercapnic ARF
NCT01784367 ·Status: COMPLETED ·Phase: NA
-
Lung and Diaphragm-Protective Ventilation by Means of Assessing Respiratory Work
NCT03612583 ·Status: COMPLETED ·Phase: PHASE1
-
Feasibility of Reducing Respiratory Drive Using the Through-flow System
NCT05642832 ·Status: RECRUITING ·Phase: NA
-
Autotitrating Versus Standard Non-invasive Ventilation (NIV) in Acute Exacerbation of Respiratory Failure
NCT01174316 ·Status: WITHDRAWN ·Phase: NA
-
Decreasing Edema With a Novel OCS Solution Trial
NCT07340710 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison Study of High Frequency Percussive Ventilation With Conventional Ventilation
NCT00308022 ·Status: WITHDRAWN ·Phase: PHASE2/PHASE3
-
Effects of Mechanical Insufflation-Exsufflation in Preventing Respiratory Failure After Extubation
NCT01424202 ·Status: COMPLETED ·Phase: NA
-
Blood Recirculation and vvECMO
NCT03200314 ·Status: COMPLETED
-
Feasibility of Mid-frequency Ventilation in Newborns With RDS: Randomized Crossover Pilot Trial
NCT01242462 ·Status: COMPLETED ·Phase: PHASE1/PHASE2