Study Comparing Hemiarch Replacement and Hemiarch Plus Stent Implantation in Acute Aortic Dissection
NCT06044259 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 72
Last updated 2025-09-29
Summary
Acute DeBakey type I aortic dissection (ATAD) is one of the most lethal surgical emergencies. The conventional operative strategy is hemiarch replacement under cardiopulmonary bypass support to replace the diseased segment of the ascending aorta. However, in patients with dissection involving the whole aortic arch and descending thoracic aorta, the presence of the persistently perfused false lumen can lead to late aneurysm formation and require a second-stage operation, and this reduces long-term survival. In the surgical literature, there is growing evidence that the presence of Distal Anastomosis New Entry (DANE), which is a new intimal defect related to the trauma created by surgical sutures, is associated with persistent perfusion of the false lumen, aortic size growth, and the need of re-operation. The Ascyrus Medical Dissection Stent (AMDS; Artivion, Atlanta, Georgia, USA) is a hybrid prosthesis with a proximal sewing collar and distal nitinol self-expanding un-covered stent system designed to reduce the occurrence of DANE and hopefully depressurize the false lumen and lead to remodeling of the aortic wall.
The investigators plan to prospectively recruit consecutive patients with acute ascending thoracic aortic dissection patients (Excluding DeBakey II) and randomized them, after informed consent, into either the conventional hemiarch replacement group (Hemiarch-C) or the hemiarch replacement plus AMDS implantation group (Hemiarch-AMDS). The participating team will collect pre-operative, intra-operative and post-operative clinical and radiological parameters for two groups of patients. Written informed consent, specifically allowing the use of clinical records for this randomized study, will be obtained from every patient prior to data collection. Complete DICOM image files of the CT scans will be evaluated by two independent fully qualified Radiologists. Our primary outcome is the radiological detection of DANE in Hemiarch-C and Hemiarch-AMDS groups within the 12-month follow-up period.
This study will be the world's first randomized control trial in ATAD to compare the prevalence of DANE in Hemiarch-C and Hemiarch-AMDS. It could be a guideline-changing study for the treatment of ATAD and its impact on the immediate survival, second-stage treatment, and long-term survival of patients suffering from ATAD.
Conditions
- Aortic Dissection
Interventions
- PROCEDURE
-
AMDS; Artivion, Atlanta, Georgia, US
Ascyrus Medical Dissection Stent (AMDS; Artivion, Atlanta, Georgia, US) hybrid prosthesis which comprises a proximal sewing collar and a distal self-expanding nitinol un-covered stent.
- PROCEDURE
-
Conventional hemiarch replacement
Coventional open hemiarch replacement
Sponsors & Collaborators
-
Chinese University of Hong Kong
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-10-01
- Primary Completion
- 2026-09-30
- Completion
- 2027-09-30
Countries
- China
Study Locations
More Related Trials
-
A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve
NCT02434263 ·Status: UNKNOWN ·Phase: NA
-
The preDIlatation in tRanscathEter aortiC Valve implanTation Trial
NCT02448927 ·Status: COMPLETED ·Phase: PHASE3
-
Targeted Testing for ATTR Among Aortic Stenosis Patients-Pilot
NCT04363294 ·Status: WITHDRAWN ·Phase: NA
-
Staged Complete Revascularization for Coronary Artery Disease vs Medical Management Alone in Patients With AS Undergoing Transcatheter Aortic Valve Replacement
NCT04634240 ·Status: RECRUITING ·Phase: NA
-
Feasibility And Safety of Early Discharge After Transfemoral Transcatheter Aortic Valve Implantation
NCT02404467 ·Status: COMPLETED
-
TEAVR With False Lumen Embolization for Aortic Dissection
NCT07198295 ·Status: NOT_YET_RECRUITING
-
Impact of Predilatation Between Self-expanding Valves
NCT04157920 ·Status: COMPLETED ·Phase: NA
-
The Safety and Effectiveness of Transcatheter Aortic Valve Raplacemet in Intermediate Risk Patients With Bicuspid Aortic Stenosis
NCT03163329 ·Status: UNKNOWN ·Phase: PHASE2
-
Repair Versus Non-repair of the Aortic Arch in Type A Aortic Dissection
NCT05912634 ·Status: ENROLLING_BY_INVITATION
-
Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population
NCT02803294 ·Status: RECRUITING ·Phase: PHASE4
-
Outcomes of Aortic Dissection Repair
NCT05927090 ·Status: ENROLLING_BY_INVITATION
-
Comparison of Self- and Balloon-expandable Valves in Patients With Ascending Aortic Dilation Undergoing Transcatheter Aortic Valve Replacement: The AAD-CHOICE
NCT06009588 ·Status: RECRUITING ·Phase: NA
-
Real-World Prospective Parallel Controlled Study on Endovascular Therapy for Improving Perfusion and Remodeling of TBAD
NCT07022145 ·Status: NOT_YET_RECRUITING
-
Assessment of Revascularization Versus Conservative Treatment in Heart Transplant Patients for a Clinical Event Reduction
NCT01795729 ·Status: TERMINATED ·Phase: PHASE3
-
Assessments of Thrombus Formation in TAVI
NCT03248232 ·Status: COMPLETED
-
HLT transfemOral Replacement of aortIc Valve Via transcatherteriZatiON
NCT02157142 ·Status: COMPLETED ·Phase: NA
-
Randomized Trial of TAVI vs. SAVR in Patients With Severe Aortic Valve Stenosis at Low to Intermediate Risk of Mortality
NCT03112980 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Stent Geometry in Sutureless Bioprosthetic Valves
NCT03753126 ·Status: COMPLETED ·Phase: NA
-
Echo-Guided vs Fluoroscopy-Guided Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis(ECHO-TAVR)
NCT07317804 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
Radiation Following Percutaneous Balloon Aortic Valvuloplasty to Prevent Restenosis
NCT00538759 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
NVT ALLEGRA TAVI System TF in Failing Surgical Aortic Bioprosthesis
NCT03287856 ·Status: COMPLETED ·Phase: NA
-
TAVI in Intermediate Risk Septuagenarians With Risk Factors Not Captured by the Traditional Surgical Risk Scores
NCT04517955 ·Status: UNKNOWN
-
accuRate Evaluation of Benefit With Optimal Medical Treatment With or Without Transcatheter Valve Repair of PARADOXical Low Flow Low Gradient Aortic Stenosis
NCT03863132 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Transcatheter Heart Valve (THV) Sizing and Leakage After Transcatheter Aortic Valve Implantation (TAVI) Before and After Establishing Routine Preprocedure Multi Slice Computerized Tomography (MSCT) Aortic Assessment. A Retrospective Registry Study
NCT02005640 ·Status: COMPLETED
-
Medtronic CoreValve REDO Study
NCT01051310 ·Status: COMPLETED ·Phase: NA