Impact of Tubing Colonization on the Incidence of Central Venous Catheter Infection
NCT06019897 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 200
Last updated 2023-10-06
Summary
The objective of this study is to assess the relationship between infusion system colonization (ramps or multi-lumen devices) and the occurrence of CVC infection/colonization.
This study is a prospective observational research that does not modify usual patient care. Its objective is to evaluate the relationship between infusion tubing colonization and the occurrence of central venous catheter colonization.
The only additional intervention is swabbing the taps at each IV line ramp at systematic ramp changes (done every 4 days) and at catheter removal. For the multi-lumen device, swabbing is only performed upon catheter removal at the level of the one-way valves.
After catheter removal, a flush (1 mL of 0.9% NaCl) of the midline is performed and cultured to assess for endoluminal colonization. The distal end of the CVC is sent for culture, following the usual practice of the department to monitor catheter colonization and infections.
The primary outcome measure is the proportion of colonized infusion systems based on the culture of the CVC.
The secondary objectives are to describe factors associated with CVC infections, to determine the incidence of colonization and infections in different locations of central venous catheters, to analyze the bacterial ecology based on the type of infusion system used, and to evaluate the ecological and economic impact of different devices (ramps vs. multi-lumen devices).
The secondary outcome measures are as follows:
Proportion of colonized infusion systems based on the colonization status of the CVC and the type of infusion system (ramps vs. multi-lumen devices) Proportion of colonized infusion systems based on the infection status of the CVC and the type of infusion system (ramps vs. multi-lumen devices) Duration of antibiotic treatment Weight of compounds used with each infusion system over the duration of CVC placement (ramps vs. multi-lumen devices) Calculation of material costs based on the infusion system used over the duration of CVC placement (ramps vs. multi-lumen devices)
Conditions
- Catheter-Related Infections
- Catheter Complications
- Catheter Infection
- Catheter-related Bloodstream Infection
- Catheter Related Complication
Sponsors & Collaborators
-
University Hospital, Angers
lead OTHER_GOV
Principal Investigators
-
sigismond lasocki, MD, PhD · CHU Angers, 49033 Angers Cedex 01, France
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-10-23
- Primary Completion
- 2024-11-30
- Completion
- 2025-01-31
More Related Trials
-
Peripheral Venous Catheter Related Blood Stream Infections
NCT05139628 ·Status: UNKNOWN
-
Study of Omiganan 1% Gel in Preventing Catheter Infections/Colonization in Patients With Central Venous Catheters
NCT00231153 ·Status: COMPLETED ·Phase: PHASE3
-
ICU-acquired Colonization and Infection Related to MDR in Immunocompromised Patients
NCT04043793 ·Status: COMPLETED
-
Immunosuppression and Intensive Care Unit-acquired Multidrug-resistant Bacteria
NCT06652126 ·Status: RECRUITING
-
Vancomycin Study: Treatment of Catheter Related Bloodstream Infection Caused by Coagulase Negative Staphylococcus
NCT00175370 ·Status: COMPLETED ·Phase: NA
-
Topical Umbilical Cord Care for the Prevention of Colonization and Invasive Infections
NCT01886001 ·Status: COMPLETED ·Phase: NA
-
Umbilical Cord Care for the Prevention of Colonization
NCT01893060 ·Status: UNKNOWN ·Phase: NA
-
Study of Catheter-related Infections Using Antibiotic-coated Versus Conventional Catheters in Children
NCT00370149 ·Status: TERMINATED ·Phase: PHASE4
-
Antibiotic Treatment for Infections of Short Term In-dwelling Vascular Catheters Due to Gram Positive Bacteria
NCT00037050 ·Status: COMPLETED ·Phase: PHASE3
-
Chlorhexidine-Impregnated Sponge Dressing: A Clinical Trial
NCT02472158 ·Status: UNKNOWN ·Phase: NA
-
Antiseptic Use and Dressing Application
NCT00389558 ·Status: COMPLETED ·Phase: PHASE4
-
Catheter Biofilm Microbiome in Infected Neonatal Catheters.
NCT01985737 ·Status: COMPLETED
-
Antimicrobial Activity of IV Clear™ Dressing - Prevention of Antimicrobial Regrowth
NCT01368120 ·Status: COMPLETED ·Phase: PHASE1
-
Comprehensive Evaluation of a Central Line Simulation Course
NCT01165398 ·Status: COMPLETED
-
Dental Study in Cancer Patients With Central Venous Catheters
NCT00798330 ·Status: COMPLETED
-
A Pilot Study To Assess The Impact Of A Camstent Coated Catheter On Clinical Bacteriuria
NCT04658719 ·Status: UNKNOWN ·Phase: NA
-
Randomized, Multicenter, Double-blind, Vancomycin-controlled Study to Evaluate the Efficacy of Ethanol Lock Solution for the Curative Treatment of Implantable Venous Access Port Infection Due to Coagulase-negative Staphylococci
NCT02411331 ·Status: UNKNOWN ·Phase: NA
-
Neonatal Bacterial Colonization Study
NCT03896893 ·Status: UNKNOWN ·Phase: NA
-
Concentration of Antimicrobials in Catheter-lock Solutions
NCT01592032 ·Status: UNKNOWN ·Phase: PHASE4
-
The Impact Of A Catheter Coating On Clinical Bacteriuria
NCT04461262 ·Status: UNKNOWN ·Phase: NA
-
A Double-blind Randomized Placebo Controlled Clinical Trial Evaluating Effect of Chlorhexidine Gluconate 2% Cloth vs Placebo Cloth Baths on the Incidence of Central Line-Associated Blood Stream Infections in Outpatient Hematopoietic Stem Cell Transplant Patients
NCT03030989 ·Status: COMPLETED ·Phase: PHASE2
-
The Effectiveness of a Bacteriophobic Coating on Urinary Catheters
NCT05719753 ·Status: COMPLETED ·Phase: NA
-
Incidence and Risk Factors for Developing Infections in Patients Colonized by CP-KPC
NCT05492539 ·Status: UNKNOWN
-
Evaluation of the Antibiofilmogramme Test During Orthopaedic Device-Related Infection
NCT03263832 ·Status: UNKNOWN
-
Port Protectors for Prevention of CLABSIs in Respiratory Semi-intensive Care Unit
NCT03486093 ·Status: COMPLETED ·Phase: NA