Integration of Intraoperative Neuromonitoring Into Decompression Surgery

NCT06009640 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10

Last updated 2023-08-25

No results posted yet for this study

Summary

To describe a novel technique by integrating the intraoperative neurophysiological monitoring (IONM) into laparoscopy to protect pelvic nerves by continuously monitoring when they are at risk during surgery.

Conditions

  • Nerve Entrapments
  • Pelvic Pain

Interventions

DEVICE

Intraoperative neurophysiological monitoring with Nicolet Endeavor IOM Machine

Integration of intraoperative neurophysiological monitoring (IONM) into laparoscopic decompression surgery to protect pelvic nerves by continuously monitoring when they are at risk during surgery.

Sponsors & Collaborators

  • Dr. Lutfi Kirdar Kartal Training and Research Hospital

    lead OTHER_GOV

Principal Investigators

  • Elif Gundogdu, M.D.Dr · Kartal Dr. Lutfi Kirdar City Hospital

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
FEMALE
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-12-01
Primary Completion
2022-02-01
Completion
2022-03-01

Countries

  • Turkey (Türkiye)

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.