Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
NCT06009458 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 387
Last updated 2025-01-14
Summary
The objective of this clinical investigation is to collect scientifically valid safety and effectiveness data on the Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear. The clinical performance data reported from this study is intended to be submitted to the U.S. Food and Drug Administration Center for Devices and Radiological Health (CDRH) in support of a new Premarket Application (PMA).
Conditions
- Myopia
Interventions
- DEVICE
-
Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
Acuity 200™ Orthokeratology Contact Lenses are intended to be worn overnight with removal during following day. The lenses are designed to produce a temporary reduction of myopia by reversibly altering the curvature of the cornea. The lenses are manufactured from fluoroxyfocon A, which is a gas permeable contact lens material composed of a siloxanyl fluoromethacrylate copolymer. The material name fluoroxyfocon A is registered with United States Adopted Name (USAN).The Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens is available in spherical, asymmetrical, aspheric, and tangential lens designs to best fit the individual cornea, using corneal topography and/or diagnostic lenses.
Sponsors & Collaborators
-
Acuity Polymers, Inc.
lead INDUSTRY
Principal Investigators
-
Mijeong Kwon Andre, MS · Andre Vision and Device Research
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 7 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-10-01
- Primary Completion
- 2025-09-30
- Completion
- 2025-09-30
- FDA Device
- Yes
Countries
- United States
- Australia
- New Zealand
Study Locations
More Related Trials
-
Postmarket Study of an Intraocular Lens Power Selection System
NCT03579433 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study of the ACRYSOF® IQ EDF Intraocular Lens (IOL)
NCT03010254 ·Status: COMPLETED ·Phase: NA
-
Optimizing the Assessment of Refractive Outcomes After Cataract Surgery
NCT02842151 ·Status: COMPLETED ·Phase: NA
-
Acrysof Toric SN60T3corneal Astigmatism Between 0.75 and 1.00 D.
NCT00542581 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study of the ACRYSOF® IQ Extended Depth of Focus Intraocular Lens (IOL)
NCT03274986 ·Status: COMPLETED ·Phase: NA
-
Investigation of Corneal Aberrations and Visual Outcomes in Patients Implanted With an AcrySof Toric Intraocular Lens (IOL)
NCT00878839 ·Status: WITHDRAWN ·Phase: NA
-
Multifocal Lens Centration and Its Effect on Visual Performance in a Presbyopic Population
NCT02228109 ·Status: COMPLETED ·Phase: NA
-
The Effects of Contact Lenses With UV/HEV-Filter on Visual Function
NCT05601544 ·Status: COMPLETED ·Phase: NA
-
North American Comfilcon A Clinical Study
NCT06902584 ·Status: RECRUITING
-
Clinical and Refractive Outcomes After Contoura® Refractive Surgery Planned Using Phorcides Surgery Planning Software
NCT04495829 ·Status: COMPLETED
-
A Continuation Study To Monitor The Long Term Safety Of Patients Completing Protocols ACU-P08-020/020A
NCT01895088 ·Status: COMPLETED ·Phase: NA
-
Improving Glare and Visual Comfort for Patients With Visual Impairment
NCT05829135 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of AcrySof IQ Vivity Extended Vision Intraocular Lenses
NCT06541795 ·Status: WITHDRAWN ·Phase: NA
-
Clinical Investigation of AcrySof® IQ PanOptix™ IOL Model TFNT00
NCT03280108 ·Status: COMPLETED ·Phase: NA
-
Retrospective / Prospective Clinical Study of AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric Intraocular Lenses
NCT02176343 ·Status: COMPLETED ·Phase: NA
-
Pilot Study of AcrySof® IQ ReSTOR® +3.0 D Multifocal Toric Intraocular Lens (IOL)
NCT01200511 ·Status: COMPLETED ·Phase: NA
-
Panoptix Trifocal Lens in Post Refractive Myopic Laser Vision Correction Surgery
NCT04698278 ·Status: UNKNOWN
-
Clinical Investigation of AcrySof® IQ ReSTOR® +3.0 D Multifocal Toric Intraocular Lens (IOL)
NCT01424189 ·Status: COMPLETED ·Phase: NA
-
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
NCT02529488 ·Status: COMPLETED ·Phase: NA
-
APIOC for Presbyopia and APIOC for Presbyopia With Astigmatism
NCT04883099 ·Status: COMPLETED ·Phase: NA
-
Visual Acuity After the Combined Binocular Implantation of +2.0 Diopters and +3.0 Diopters Oculentis Multifocal Intraocular Lenses.
NCT02633228 ·Status: COMPLETED ·Phase: PHASE4
-
Low Cylinder Toric
NCT00732030 ·Status: COMPLETED ·Phase: PHASE4
-
Clinical Investigation of the AcrySof IQ Vivity Extended Vision Intraocular Lens (IOL)
NCT04098367 ·Status: COMPLETED ·Phase: NA
-
A Real-World Evidence (RWE) Long-Term Follow-Up Study to Assess Outcomes of Alcon Monofocal Intraocular Lenses
NCT05799950 ·Status: COMPLETED
-
Visual Quality and Performance of Eyes With Asqelio™ EDoF Toric Lenses
NCT06707545 ·Status: COMPLETED