Comparison Physiological Effects According to Preoxygenation Method Using EIT
NCT05962073 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2024-04-17
Summary
Hypoxemia during endotracheal intubation is one of this procedure's most frequent and severe complications, which can lead to cardiac arrest and other adverse outcomes. Although various studies have been conducted to ensure the safety of endotracheal intubation, most of them have focused on the physiological changes during the procedure in surgical settings, where general anesthesia is administered to healthy subjects. However, the physiological characteristics of critically ill patients who require endotracheal intubation in the intensive care unit (ICU) may differ from those of healthy subjects. When comparing the oxygen saturation-dissociation curve of healthy subjects and critically ill patients, the latter show a steeper decline in oxygen saturation (SpO2) below 90% when hypoxemia occurs. Clinically, it is difficult to maintain or recover oxygen saturation when it drops. Therefore, preoxygenation is also essential for critically ill patients with a relatively small lung reservoir, as it can help maintain higher and longer oxygen saturation during endotracheal intubation. For this reason, apneic oxygenation was proposed in the 1950s as a method of oxygen delivery during general anesthesia for surgery, and clinical randomized controlled trials (RCTs) applying it to critically ill patients in the ICU have been conducted since 20 years ago. In an observational study by Macamn et al., the adjusted odds ratio (OR) of a bag valve mask was 1, while that of a high-flow nasal cannula (HFNC) was 5.75 and that of non-invasive ventilation (NIV) was 0.10 when different preoxygenation methods were used. n FLORARI 2, a large-scale clinical RCT comparing NIV and HFNC with or without apneic oxygenation, NIV was significantly more effective than HFNC in reducing severe hypoxemia. Based on these previous studies, the investigators can infer that supplying oxygen during laryngoscopy is not very effective in preventing hypoxemia in critically ill patients. However, there is no guideline on which device to choose for preoxygenation in the ICU, and NIV or HFNC are selected according to the operator's preference. This is because few studies have examined the physiological effects of these devices on patients. Therefore, in this study, the investigators aim to compare the clinical outcomes and adverse events of NIV and HFNC as preoxygenation methods for endotracheal intubation in critically ill patients with acute respiratory failure and to evaluate their physiological effects using electrical impedance tomography.
Conditions
- Acute Hypoxemic Respiratory Failure
Interventions
- DEVICE
-
HFNC
High-flow oxygen therapy before intubation for preoxygenation
Sponsors & Collaborators
-
Samsung Medical Center
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-08-01
- Primary Completion
- 2024-02-28
- Completion
- 2024-07-30
Countries
- South Korea
Study Locations
More Related Trials
-
Feasibility of End-tidal Oxygen Concentration Monitoring During Preoxygenation for Intubation in the Intensive Care Unit.
NCT05409573 ·Status: RECRUITING ·Phase: NA
-
Desaturation Validation of INVSENSOR00028
NCT03704636 ·Status: COMPLETED ·Phase: NA
-
Mask Hypoxia in Subjects Using Masks to Prevent Infection Spread
NCT04670484 ·Status: WITHDRAWN ·Phase: NA
-
Transcutaneous Monitoring of Oxygen and Carbon Dioxide in Surgical Patients
NCT04040478 ·Status: COMPLETED
-
Accuracy Validation of a Pulse Oximetry Monitor
NCT02506010 ·Status: WITHDRAWN
-
The Use of Optical Oximetry in Determining Gastrointestinal Complications After the Hybrid Procedure
NCT02060825 ·Status: TERMINATED
-
Improved Patient Recovery After Anesthesia With Hypercapnia Hyperpnoea
NCT00708526 ·Status: COMPLETED ·Phase: NA
-
Validation of Noninvasive Hemoglobin, Comparison of PVI to Standard Methods, and Validation of Clinical Efficacy of ORI
NCT02841397 ·Status: COMPLETED
-
Desaturation Validation of INVSENSOR00037
NCT04002973 ·Status: COMPLETED ·Phase: NA
-
Novel Non-Invasive Monitoring Parameter in Healthy Volunteers
NCT01294514 ·Status: COMPLETED
-
A Study of the Effect of Arterial Carbon Dioxide Tension on the Recovery of Spontaneous Respiration
NCT01733446 ·Status: COMPLETED ·Phase: NA
-
Apneic Oxygenation Via Nasal Cannulae Prevents Arterial Hypoxemia
NCT00782977 ·Status: COMPLETED ·Phase: NA
-
Cerebral Oximetry in Single Lung Ventilation Thoracic Surgery
NCT01866657 ·Status: TERMINATED ·Phase: NA
-
Alternate Methodology of Pulse Oximeter Validation
NCT03628560 ·Status: SUSPENDED ·Phase: NA
-
An Invasive Controlled Desaturation Study to Determine the Accuracy of the CART-I Pulse Oximeter
NCT05693961 ·Status: COMPLETED ·Phase: NA
-
Waveform Capnography Compared to Colorimetric Carbon Dioxide Detection During Tracheal Intubation of Critically Ill Adults
NCT06934876 ·Status: RECRUITING
-
Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation
NCT00920569 ·Status: TERMINATED
-
Understanding Physiology During Float-REST and the Consequential Effects on Subjective and Objective Recovery
NCT04415970 ·Status: COMPLETED ·Phase: NA
-
Validation of Respiration Rate Algorithms
NCT01472133 ·Status: COMPLETED
-
Impact of Hypoxia on Resting and Exertional Right Ventricular Performance
NCT05272514 ·Status: COMPLETED
-
OM2 Motion Verification Study
NCT06415786 ·Status: COMPLETED
-
Desaturation Validation of INVSENSOR00036
NCT04002960 ·Status: COMPLETED ·Phase: NA
-
The Use of the Fluid IV Alert Monitor to Decrease the Incidence of Undetected Empty IV Bag in Dimmed Operating Rooms
NCT02666027 ·Status: COMPLETED ·Phase: NA
-
Comparison of Pulse Oximetry (SpO2) With Different Oximeters and Arterial Saturation (SaO2): Oxygap2 Study
NCT06102499 ·Status: RECRUITING
-
The Effect of 10 cm Catheter Mount on Malfunction of Capnometers Under the Conditions of Water
NCT02072343 ·Status: COMPLETED ·Phase: NA